Kathleen Denis

Prof. Kathleen Denis

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2010 in European Journal of Radiology
Verified
Journal Article
Closed access
XLXin Liang
Xin Liang
ILIvo Lambrichts
Ivo Lambrichts
YSYi Sun
Yi Sun
KDKathleen Denis
Kathleen Denis
BHBassam Hassan
Bassam Hassan
RJReinhilde Jacobs
Reinhilde Jacobs

1 September 2008 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
MLM Loubele
M Loubele
RJReinhilde Jacobs
Reinhilde Jacobs
FMF Maes
F Maes
KDKathleen Denis
Kathleen Denis
SWS White
S White
PSP Suetens
P Suetens
Objectives: To evaluate image quality by examining segmentation accuracy and assess radiation dose for cone beam CT (CBCT) scanners. Methods: A skull phantom, scanned by a laser scanner, and a contrast phantom were used to evaluate segmentation accuracy. The contrast phantom consisted of a polymethyl methacrylate (PMMA) cylinder with cylindrical inserts of air, bone and PMMA. The phantoms were scanned on the (1) Accuitomo 3D, (2) MercuRay, (3) NewTom 3G, (4) i-CAT and (5) Sensation 16. The structures were segmented with an optimal threshold. Thicknesses of the bone of the mandible and the diameter of the cylinders in the contrast phantom were measured across lines at corresponding places in the CT image vs a ground truth. The accuracy was in the 95th percentile of the difference between corresponding measurements. The correlation between accuracy in skull and contrast phantom was calculated. The radiation dose was assessed by DPI100,c (dose profile integral 100,c) at the central hole of a CT dose index (C...

1 June 2001 in International Congress Series
Verified
Journal Article
Closed access
KDKathleen Denis
Kathleen Denis
GHG Van Ham
G Van Ham
JSJ Vander Sloten
J Vander Sloten
RAR Van Audekercke
R Van Audekercke
GPG Van der Perre
G Van der Perre
GFG Fabry
G Fabry

26 August 2020 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
QGQuentin Goossens
Quentin Goossens
LPLeonard Cezar Pastrav
Leonard Cezar Pastrav
JRJorg Roosen
Jorg Roosen
MMMichiel Mulier
Michiel Mulier
WDWim Desmet
Wim Desmet
KDKathleen Denis
Kathleen Denis

27 July 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
AJAllan Javaux
Allan Javaux
DBDavid Bouget
David Bouget
CGCaspar Gruijthuijsen
Caspar Gruijthuijsen
DSDanail Stoyanov
Danail Stoyanov
TVTom Vercauteren
Tom Vercauteren
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Purpose Smaller incisions and reduced surgical trauma made minimally invasive surgery (MIS) grow in popularity even though long training is required to master the instrument manipulation constraints. While numerous training systems have been developed in the past, very few of them tackled fetal surgery and more specifically the treatment of twin-twin transfusion syndrome (TTTS). To address this lack of training resources, this paper presents a novel mixed-reality surgical trainer equipped with comprehensive sensing for TTTS procedures. The proposed trainer combines the benefits of box trainer technology and virtual reality systems. Face and content validation studies are presented and a use-case highlights the benefits of having embedded sensors. Methods Face and content validity of the developed setup was assessed by asking surgeons from the field of fetal MIS to accomplish specific tasks on the trainer. A small use-case investigates whether the trainer sensors are able to distinguish between an easy and difficult scenario. Results The trainer was deemed sufficiently realistic and its proposed tasks relevant for practicing the required motor skills. The use-case demonstrated that the motion and force sensing capabilities of the trainer were able to analyze surgical skill. Conclusion The developed trainer for fetal laser surgery was validated by surgeons from a specialized center in fetal medicine. Further similar investigations in other centers are of interest, as well as quality improvements which will allow to increase the difficulty of the trainer. The comprehensive sensing appeared to be capable of objectively assessing skill.

29 July 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
QGQuentin Goossens
Quentin Goossens
SLSteven Leuridan
Steven Leuridan
PHPetr Henyš
Petr Henyš
JRJorg Roosen
Jorg Roosen
LPLeonard Cezar Pastrav
Leonard Cezar Pastrav
JSJos Vander Sloten
Jos Vander Sloten
In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion.