Ventilation-controlled fires tend to be the worst for toxicity, because they produce large amounts of fire effluent containing high yields of toxic products. In order to examine the dependence of the amount of chosen few main combustion gases under ventilation-controlled conditions, a PVC-insulated copper electric wire with unknown composition (PVC filled with chalk) was studied by mean of a steady state tube furnace. For the tested wire, lower values of CO2 yields at different ventilation conditions were obtained than for the reference pure polymer unplasticized PVC and additionally tested pure LDPE, the yields were higher three times in the case of PVC and two times in the case of LDPE than those received for wire at the same ventilation conditions, which pointed out decreasing contribution of hyperventilation effect to human during cable fire. In contrast, higher values of toxic CO yields, four times higher, were obtained for the PVC-insulated electric wire rather than for the pure polymers. The maximum value of CO yield (0.57 g/g) was determined in the case of 5 L/min of primary airflow and decreased with increasing ventilation. The measured yields of hydrocarbons were similar to the reference values except for the equivalence ratio ϕ = 0.27, where hydrocarbon yield was equal to 0.45 g/g. The HCl yield of fire effluents from the PVC-insulated wire was shown to be independent of ventilation conditions. The corrosive reaction between copper and the HCl species and the flame-retardant mechanisms of the additives, caused the lower values of HCl in the fire effluent of the PVC-insulated copper wire than for pure polymer.
A routine cone calorimeter procedure, the theoretical analysis method, based on a set of ignitability data from the cone calorimeter, has been performed. The five sets of ignition times at different irradiance levels were used for obtaining experimental data needed for analysis. The cone calorimeter tests were performed with horizontal specimens of the size 100 mm × 100 mm consisting of eight pieces of commercial poly(vinyl chloride) coaxial power cable. Specimen combustion was carried out under external heat flux of constant values equal to 10, 20, 30, 40 and 50 kW·m−2, respectively. Standard fire parameters and time to ignition were used for analysis. The results indicate that for each fire parameter, a rising trend with an increase in radiant heat flux has been observed. It was shown that the use of poly(vinyl chloride)-based cables is a potential fire safety hazard due to the emission of heat and a large amount of acid smoke. Quintiere’s theory has been shown as a useful tool for fire modelling by using the data from small-scale tests rather than large geometrical scale cable experiments. Large scale cable test (EN 50399) results are also presented and compared with cone calorimeter data.
The aim of work is to describe and to complement the existing knowledge on the effect of redispersible polymer powder on the setting time of cement mortar as measured by means of ultrasonic apparatus. The mortars were simple mixtures of filler in the form of quartz sand, Portland cement CEM I 42.5 R as binder and methyl hydroxyethyl cellulose. The mortar additives were two commercially available redispersible polymer powders in an amount of 0-5% of total weight. The chosen polymers had different chemical structure: styrene-acrylic copolymer (SA), vinyl acetate-ethylene copolymer (ET), and minimum film forming temperature (MFFT). The amount of water was constant and equal to 20% of the total weight of the mortar. Conclusions: - even the small amount of redispersible polymer powder added to the cement mortar has a significant influence on mortar’s initial and final setting time and this effect strongly depends on the percentage of the additive, - the chemical structure of the studied redispersible polymer powders did not influence the behaviour of the whole chemical system, - the further studies on technical properties, such as mechanical strength and permeability are planned in order to find more information on the structure of hardened mortar.
The significant number of cables of different materials and construction used extensively in building objects increases their fire load and, therefore, strongly influences safety in the case of fire. The purpose of the study was to identify relevant factors related to the construction of electrical cables, and perform a qualitative and quantitative assessment of their influence on specific fire properties, such as heat release and smoke production. Fifteen cables of different construction and materials were studied using the EN 50399 standard test. The analysis was focused on cable constructional-material parameters related to the chemical composition of non-metallic elements and the number and shape of conductors in the cable, as well as the concentric barrier as armor or the copper concentric conductor. The conclusions drawn from the experiments were: (1) Construction, the number of conductors, and the presence of armor or concentric metallic conductors improve the fire properties by forming a barrier against flame penetration through the cable; (2) the use of copper conductors resulted in a decrease of fire parameters compared to cables with aluminum conductors (peakHRRav parameter even four times lower for copper cable); (3) construction material based on non-plasticized poly(vinyl chloride) (PVC) significantly reduced the fire properties of cables more than halogen-free materials (LS0H) (peakHRRav parameter more than 17 times higher for the fully halogenated cable), which is due to the decomposition process of the material; and (4) no clear relationship between the fire parameters and the cable parameter, χ, was found.