Bartłomiej K. Papis

Dr. Bartłomiej K. Papis


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
JFJadwiga Halina Fangrat
Jadwiga Halina Fangrat
BPBartłomiej K. Papis
Bartłomiej K. Papis
A routine cone calorimeter procedure, the theoretical analysis method, based on a set of ignitability data from the cone calorimeter, has been performed. The five sets of ignition times at different irradiance levels were used for obtaining experimental data needed for analysis. The cone calorimeter tests were performed with horizontal specimens of the size 100 mm × 100 mm consisting of eight pieces of commercial poly(vinyl chloride) coaxial power cable. Specimen combustion was carried out under external heat flux of constant values equal to 10, 20, 30, 40 and 50 kW·m−2, respectively. Standard fire parameters and time to ignition were used for analysis. The results indicate that for each fire parameter, a rising trend with an increase in radiant heat flux has been observed. It was shown that the use of poly(vinyl chloride)-based cables is a potential fire safety hazard due to the emission of heat and a large amount of acid smoke. Quintiere’s theory has been shown as a useful tool for fire modelling by using the data from small-scale tests rather than large geometrical scale cable experiments. Large scale cable test (EN 50399) results are also presented and compared with cone calorimeter data.

4 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
JFJadwiga Halina Fangrat
Jadwiga Halina Fangrat
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
BPBartłomiej K. Papis
Bartłomiej K. Papis
Electrical installations are a significant component of fire load inside a building, although they are often neglected in the overall fire safety analysis and are not subjected to any kind of fire safety evaluation of a building. A typical electrical installation unconnected to the mains was experimentally studied using a single burning item (SBI) test apparatus, fixed to two types of popular non-combustible or combustible (wooden-based) backgrounds simulating a typical building internal wall or ceiling. The semi-real scale test showed that poly(vinyl chloride) (PVC) cable, commonly used in installations in buildings in Europe and used in SBI tests, showed high fire properties related to heat release, smoke production and flame spread to other interior elements. The results of the electrical circuit connected to the main measurements carried out showed a significant impact of the heating effect towards the uncovered surface socket, causing the possibility of easy ignition inside the installation. In conclusion, it was found that even a relatively simple and short section of electrical installation resulted in a significant increase in the heat release rate and smoke generation parameters, obtained during the SBI tests, and as a consequence a reduction of one or two reaction to fire euroclasses of construction materials for internal walls.

1 October 2025 in Materials
Verified
Journal Article
Open access
PDF file
AMAnna Magiera
Anna Magiera
MKMonika Kuznia
Monika Kuznia
RSRafal Stanik
Rafal Stanik
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
Maik GudeMaik Gude
Maik Gude
BPBartłomiej K. Papis
Bartłomiej K. Papis
The increasing demand for sustainable construction materials has driven interest in utilizing waste biomass within polymer composites. Rigid polyurethane foams, widely valued for thermal insulation, exhibit a significant flammability issue. This study investigates the impact of incorporating various waste biomass materials, including brewers’ spent grain, coffee grounds, and soybean husk and their combustion ashes on the selected properties of rigid polyurethane foams. The primary objective is to assess the potential of these eco-friendly additives as replacements for traditional raw materials, aiming to enhance fire resistance and thermal stability and thereby promoting circular economy principles in the construction sector. Composite foam samples were fabricated using a mixing and casting technique, incorporating 5% wt. of fillers into the polymer matrix. Thermal stability and flammability were evaluated using cone calorimetry and thermogravimetric analysis. The findings indicated that while biomass inclusion did not significantly improve char formation, the addition of ash substantially increased char yield, a critical factor in fire suppression. Although biomass and ash may influence flammability, they do not inherently bolster the intrinsic thermal stability of the polyurethane matrix itself.

5 April 2018 in MATERIAŁY BUDOWLANE
Verified
Journal Article
Closed access
BPBartłomiej K. Papis
Bartłomiej K. Papis

5 July 2016 in MATERIAŁY BUDOWLANE
Verified
Journal Article
Closed access
BPBartłomiej K. Papis
Bartłomiej K. Papis