Katarzyna Kaczorek-Chrobak

Dr. Katarzyna Kaczorek-Chrobak

Instytut Techniki Budowlanej
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
MKMonika Kuznia
Monika Kuznia
AMAnna Magiera
Anna Magiera
Beata Zygmunt-KowalskaBeata Zygmunt-Kowalska
Beata Zygmunt-Kowalska
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
Kinga PielichowskaKinga Pielichowska
Kinga Pielichowska
Wojciech JerzakWojciech Jerzak
Wojciech Jerzak
There is currently a growing demand for more effective thermal insulation materials with the best performance properties. This research paper presents the investigation results on the influence of two types of filler on the structure and properties of rigid polyurethane foam composites. Fly ash as a product of coal combustion in power plants and microspheres of 5, 10, 15, and 20 wt.%, were used as rigid polyurethane foams modifiers. The results of thermal analysis, mechanical properties testing, and cellular structure investigation performed for polyurethane composites show that the addition of fly ash, up to 10 wt.%, significantly improved the majority of the tested parameters. The use of up to 20 wt.% of microspheres improves the mechanical and thermal properties and thermal stability of rigid polyurethane foams.

2 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
JFJadwiga Halina Fangrat
Jadwiga Halina Fangrat
Ventilation-controlled fires tend to be the worst for toxicity, because they produce large amounts of fire effluent containing high yields of toxic products. In order to examine the dependence of the amount of chosen few main combustion gases under ventilation-controlled conditions, a PVC-insulated copper electric wire with unknown composition (PVC filled with chalk) was studied by mean of a steady state tube furnace. For the tested wire, lower values of CO2 yields at different ventilation conditions were obtained than for the reference pure polymer unplasticized PVC and additionally tested pure LDPE, the yields were higher three times in the case of PVC and two times in the case of LDPE than those received for wire at the same ventilation conditions, which pointed out decreasing contribution of hyperventilation effect to human during cable fire. In contrast, higher values of toxic CO yields, four times higher, were obtained for the PVC-insulated electric wire rather than for the pure polymers. The maximum value of CO yield (0.57 g/g) was determined in the case of 5 L/min of primary airflow and decreased with increasing ventilation. The measured yields of hydrocarbons were similar to the reference values except for the equivalence ratio ϕ = 0.27, where hydrocarbon yield was equal to 0.45 g/g. The HCl yield of fire effluents from the PVC-insulated wire was shown to be independent of ventilation conditions. The corrosive reaction between copper and the HCl species and the flame-retardant mechanisms of the additives, caused the lower values of HCl in the fire effluent of the PVC-insulated copper wire than for pure polymer.

15 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
JFJadwiga Halina Fangrat
Jadwiga Halina Fangrat
BPBartłomiej K. Papis
Bartłomiej K. Papis
A routine cone calorimeter procedure, the theoretical analysis method, based on a set of ignitability data from the cone calorimeter, has been performed. The five sets of ignition times at different irradiance levels were used for obtaining experimental data needed for analysis. The cone calorimeter tests were performed with horizontal specimens of the size 100 mm × 100 mm consisting of eight pieces of commercial poly(vinyl chloride) coaxial power cable. Specimen combustion was carried out under external heat flux of constant values equal to 10, 20, 30, 40 and 50 kW·m−2, respectively. Standard fire parameters and time to ignition were used for analysis. The results indicate that for each fire parameter, a rising trend with an increase in radiant heat flux has been observed. It was shown that the use of poly(vinyl chloride)-based cables is a potential fire safety hazard due to the emission of heat and a large amount of acid smoke. Quintiere’s theory has been shown as a useful tool for fire modelling by using the data from small-scale tests rather than large geometrical scale cable experiments. Large scale cable test (EN 50399) results are also presented and compared with cone calorimeter data.

29 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
JFJadwiga Halina Fangrat
Jadwiga Halina Fangrat
The significant number of cables of different materials and construction used extensively in building objects increases their fire load and, therefore, strongly influences safety in the case of fire. The purpose of the study was to identify relevant factors related to the construction of electrical cables, and perform a qualitative and quantitative assessment of their influence on specific fire properties, such as heat release and smoke production. Fifteen cables of different construction and materials were studied using the EN 50399 standard test. The analysis was focused on cable constructional-material parameters related to the chemical composition of non-metallic elements and the number and shape of conductors in the cable, as well as the concentric barrier as armor or the copper concentric conductor. The conclusions drawn from the experiments were: (1) Construction, the number of conductors, and the presence of armor or concentric metallic conductors improve the fire properties by forming a barrier against flame penetration through the cable; (2) the use of copper conductors resulted in a decrease of fire parameters compared to cables with aluminum conductors (peakHRRav parameter even four times lower for copper cable); (3) construction material based on non-plasticized poly(vinyl chloride) (PVC) significantly reduced the fire properties of cables more than halogen-free materials (LS0H) (peakHRRav parameter more than 17 times higher for the fully halogenated cable), which is due to the decomposition process of the material; and (4) no clear relationship between the fire parameters and the cable parameter, χ, was found.

4 December 2020 in Energies
Verified
Journal Article
Open access
PDF file
JFJadwiga Halina Fangrat
Jadwiga Halina Fangrat
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
BPBartłomiej K. Papis
Bartłomiej K. Papis
Electrical installations are a significant component of fire load inside a building, although they are often neglected in the overall fire safety analysis and are not subjected to any kind of fire safety evaluation of a building. A typical electrical installation unconnected to the mains was experimentally studied using a single burning item (SBI) test apparatus, fixed to two types of popular non-combustible or combustible (wooden-based) backgrounds simulating a typical building internal wall or ceiling. The semi-real scale test showed that poly(vinyl chloride) (PVC) cable, commonly used in installations in buildings in Europe and used in SBI tests, showed high fire properties related to heat release, smoke production and flame spread to other interior elements. The results of the electrical circuit connected to the main measurements carried out showed a significant impact of the heating effect towards the uncovered surface socket, causing the possibility of easy ignition inside the installation. In conclusion, it was found that even a relatively simple and short section of electrical installation resulted in a significant increase in the heat release rate and smoke generation parameters, obtained during the SBI tests, and as a consequence a reduction of one or two reaction to fire euroclasses of construction materials for internal walls.

1 October 2025 in Materials
Verified
Journal Article
Open access
PDF file
AMAnna Magiera
Anna Magiera
MKMonika Kuznia
Monika Kuznia
RSRafal Stanik
Rafal Stanik
KKKatarzyna Kaczorek-Chrobak
Katarzyna Kaczorek-Chrobak
Maik GudeMaik Gude
Maik Gude
BPBartłomiej K. Papis
Bartłomiej K. Papis
The increasing demand for sustainable construction materials has driven interest in utilizing waste biomass within polymer composites. Rigid polyurethane foams, widely valued for thermal insulation, exhibit a significant flammability issue. This study investigates the impact of incorporating various waste biomass materials, including brewers’ spent grain, coffee grounds, and soybean husk and their combustion ashes on the selected properties of rigid polyurethane foams. The primary objective is to assess the potential of these eco-friendly additives as replacements for traditional raw materials, aiming to enhance fire resistance and thermal stability and thereby promoting circular economy principles in the construction sector. Composite foam samples were fabricated using a mixing and casting technique, incorporating 5% wt. of fillers into the polymer matrix. Thermal stability and flammability were evaluated using cone calorimetry and thermogravimetric analysis. The findings indicated that while biomass inclusion did not significantly improve char formation, the addition of ash substantially increased char yield, a critical factor in fire suppression. Although biomass and ash may influence flammability, they do not inherently bolster the intrinsic thermal stability of the polyurethane matrix itself.