Lei Zhao

Dr. Lei Zhao

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LZLei Zhao
Lei Zhao
LZLingyu Zhou
Lingyu Zhou
GZGuangchao Zhang
Guangchao Zhang
TWTian-Yu Wei
Tian-Yu Wei
AMAkim djibril gildas MAHUNON
Akim djibril gildas MAHUNON
YZyingying Zhang
yingying Zhang
To study the temperature distribution in the China Railway Track System Type II ballastless slab track on a high-speed railway (HSR) bridge, a 1:4 scaled specimen of a simply-supported concrete box girder bridge with a ballastless track was constructed in laboratory. Through a rapid, extreme high temperature test in winter and a conventional high temperature test in summer, the temperature distribution laws in the track on the HSR bridge were studied, and the vertical and transverse temperature distribution trend was suggested for the track. Firstly, the extreme high temperature test results showed that the vertical temperature and the vertical temperature difference distribution in the track on HSR bridge were all nonlinear with three stages. Secondly, the extreme high temperature test showed that the transverse temperature distribution in the track was of quadratic parabolic nonlinear form, and the transverse temperature gradient in the bottom base was significantly higher than that of the other layers of the track. Thirdly, the three-dimensional temperature distribution in the track on HSR bridge was a nonlinear, three-stage surface. Furthermore, similar regularities were also obtained in the conventional high temperature test, in which the temperature span ranges were different from those of the extreme high temperature test. In addition, the conventional high temperature test also showed that under the natural environment conditions, the internal temperature gradient in the track layers changed periodically (over a period of 24 h).

19 February 2021 in ACS Omega
Verified
Journal Article
Open access
XRXian Rong
Xian Rong
ZWZhixin Wang
Zhixin Wang
XXXueyang Xing
Xueyang Xing
LZLei Zhao
Lei Zhao
Geopolymers are considered to be green materials with excellent fire resistance performance and potential substitutes for ordinary Portland cement (OPC). This review article focuses on the adhesion of geopolymer coatings subjected to elevated temperature. Their high adhesion strength is the basis for geopolymers being used as coating materials to work with the substrate. The adhesion strength is related to many factors, such as chemical composition of the raw materials, the formulation of the geopolymer, substrate type, surface roughness of the substrate, etc. The Si/Al ratio has different effects on compressive strength and bonding strength. The water content affects the polymerization process—the adhesion strength decreases with increasing water content. Careful tailoring of the mix ratio design is essential to make the geopolymer coating have excellent adhesive performance. These mix design factors include Si/Al ratio, Al/Na ratio, water content, precursor type, alkali cation type, curing conditions, etc.

8 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LZLingyu Zhou
Lingyu Zhou
TWTianyu Wei
Tianyu Wei
GZGuangchao Zhang
Guangchao Zhang
YZyingying Zhang
yingying Zhang
AMAkim djibril gildas MAHUNON
Akim djibril gildas MAHUNON
Wei GuoWei Guo
Wei Guo
To study the initiation and expansion of the interlayer gap of the China Railway Track System Type II (CRTS-II) ballastless slab track structure under the action of repeated thermal loading as well as the influence of the interlayer gap on the displacement, strain and stiffness of the track structure, a 1/4 scale three-span ballastless slab track simply supported bridge structural system specimen was developed and 18 cycles of extremely thermal loading tests were carried out. Static loading tests were carried out before and after the repeated thermal loading test and the effects of the repeated temperature loading on the mechanical properties of the structural system were analyzed. The test results show that under repeated temperature loading, there is a gap between the track slab and cement emulsified asphalt (CA) mortar near the fixed end section of the beam (close to the shear slots). The interlayer gap gradually expands to the mid-span section in a “stepped” shape in three stages: initiation, expansion and stabilization. Under the same temperature load, the camber of the concrete box beam decreases gradually while that of the track structure increases gradually with the increase of the interlayer gap length. During the three stages of interlayer gap development, the track structure stiffness degrades gradually, and the fastest reduction rate during the expansion stage. At the end of the 18th cycle of thermal loading, a degradation of 14.96% and 2.52% is observed in the stiffness of the track structure and that of the ballastless track-bridge structural system, respectively.

1 May 2021 in Construction and Building Materials
Verified
Journal Article
Closed access
LZLing-Yu Zhou
Ling-Yu Zhou
LZLei Zhao
Lei Zhao
AMAkim djibril gildas MAHUNON
Akim djibril gildas MAHUNON
YZYing-Ying Zhang
Ying-Ying Zhang
HLHua-Yong Li
Hua-Yong Li
YYYa-Hui Yuan
Ya-Hui Yuan

27 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
YZyingying Zhang
yingying Zhang
LZLingyu Zhou
Lingyu Zhou
AMAkim djibril gildas MAHUNON
Akim djibril gildas MAHUNON
GZGuangchao Zhang
Guangchao Zhang
XPXiusheng Peng
Xiusheng Peng
YYYahui Yuan
Yahui Yuan
The mechanical performance of China Railway Track System type II (CRTS II) ballastless track suitable for High-Speed Railway (HSR) bridges is investigated in this project by testing a one-quarter-scaled three-span specimen under thermal loading. Stress analysis was performed both experimentally and numerically, via finite-element modeling in the latter case. The results showed that strains in the track slab, in the cement-emulsified asphalt (CA) mortar and in the track bed, increased nonlinearly with the temperature increase. In the longitudinal direction, the zero-displacement section between the track slab and the track bed was close to the 1/8L section of the beam, while the zero-displacement section between the track slab and the box girder bridge was close to the 3/8L section. The maximum values of the relative vertical displacement between the track bed and the bridge structure occurred in the section at three-quarters of the span. Numerical analysis showed that the lower the temperature, the larger the tensile stresses occurring in the different layers of the track structure, whereas the higher the temperature, the higher the relative displacement between the track system and the box girder bridge. Consequently, quantifying the stresses in the various components of the track structure resulting from sudden temperature drops and evaluating the relative displacements between the rails and the track bed resulting from high-temperature are helpful in the design of ballastless track structures for high-speed railway lines.

9 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LZLingyu Zhou
Lingyu Zhou
YYYahui Yuan
Yahui Yuan
LZLei Zhao
Lei Zhao
AMAkim djibril gildas MAHUNON
Akim djibril gildas MAHUNON
LZLifan Zou
Lifan Zou
WHWenqi Hou
Wenqi Hou
To study the mechanical properties of the China Railway Track System type II (CRTS-II) ballastless slab track structure, a 1/4-scale specimen of a CRTS-II slab ballastless track-32-m standard prefabricated simply supported box girder bridge with three spans and two high-speed railway lines was developed. The mechanical properties of the structure under the action of daily natural temperatures were studied under the natural environmental conditions. The structural strain and relative interlayer displacements were analyzed. The results show that the temperature of the CRTS-II ballastless track-bridge structural system changes periodically every 24 h. The strain of the structural layers of the track system first increases and then decreases sinusoidally, and the internal strain of the track system lags along the vertical depth direction. The relative displacement between the layers of the ballastless track bridge structure system increases with the increase in temperature. The extreme value of the vertical relative displacement appears between the track bed and the bridge at section 1/4 in the span, so it should be paid attention to by the maintenance personnel. Due to the constraint of the shear slots, the structural strain and relative displacement at the fixed end near the shear slots are smaller than those at the sliding end. The mid-span deflection is the largest, and the overall deflection during the cooling phase is more significant than that during the heating phase.