Behrouz Nourozi

Mr. Behrouz Nourozi

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2023 in Building and Environment
Verified
Journal Article
Open access
BNBehrouz Nourozi
Behrouz Nourozi
AWAneta Wierzbicka
Aneta Wierzbicka
RYRunming Yao
Runming Yao
SSSasan Sadrizadeh
Sasan Sadrizadeh

1 January 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
BNBehrouz Nourozi
Behrouz Nourozi
Qian WangQian Wang
Qian Wang
APAdnan Ploskić
Adnan Ploskić

1 April 2019 in Resources, Conservation and Recycling
Verified
Journal Article
Closed access
BNBehrouz Nourozi
Behrouz Nourozi
Qian WangQian Wang
Qian Wang
APAdnan Ploskić
Adnan Ploskić

1 October 2021 in Building and Environment
Verified
Journal Article
Open access
CWCong Wang
Cong Wang
Qian WangQian Wang
Qian Wang
BNBehrouz Nourozi
Behrouz Nourozi
HPHenrikki Pieskä
Henrikki Pieskä
APAdnan Ploskić
Adnan Ploskić

15 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
THTrond Thorgeir Harsem
Trond Thorgeir Harsem
BNBehrouz Nourozi
Behrouz Nourozi
ABAmirmohammad Behzadi
Amirmohammad Behzadi
SSSasan Sadrizadeh
Sasan Sadrizadeh
The present work introduces an innovative yet feasible heating system consisting of a ground source heat pump, borehole thermal energy storage, an auxiliary heater, radiators, and ventilation coils. The concept is developed by designing a new piping configuration monitored by a smart control system to reduce the return flow temperature and increase the temperature differential between the supply and return flows. The radiators and ventilation heating circuits are connected in series to provide the heat loads with the same demand. The investigation of the proposed model is performed through developed Python code considering a case study hospital located in Norway. The article presents, after validation of the primary heating system installed in the hospital, a parametric investigation to evaluate the effect of main operational parameters on the performance metrics of both the heat pump and the total system. According to the results, the evaporator temperature is a significant parameter that considerably impacts the system performance. The parametric study findings show that the heat pumps with a thermal capacity of 400 kW and 600 kW lead to the highest heat pump and total seasonal performance factors, respectively. It is also observed that increasing the heat pump capacity does not affect the performance indicators when the condensation temperature is 40 °C and the heat recovery is 50%. Moreover, choosing a heat pump with a smaller capacity at the heat recovery of 75% (or higher) would be an appropriate option because the seasonal performance values are not varied by changing the heat pump capacity. The results reveal that reducing return temperature under a proper parameters selection results in substantially higher seasonal performance factors of the heat pump and total system. These outcomes are in-line with the United Nations sustainable development goals including Sustainable Cities and Communities.

9 March 2023 in Journal of Energy Storage
Verified
Journal Article
Open access
LHLars Herre
Lars Herre
BNBehrouz Nourozi
Behrouz Nourozi
MHMohammad Reza Hesamzadeh
Mohammad Reza Hesamzadeh
QWQian Wang
Qian Wang
LSLennart Söder
Lennart Söder