Since studies on privacy-preserving database outsourcing have been spotlighted in a cloud computing, databases need to be encrypted before being outsourced to the cloud. Rao et al. proposed a k-Means clustering algorithm that supports the protection of sensitive data by using a paillier cryptosystem[1]. However, the existing algorithm is inefficient due to bit-array based comparison. To solve this problem, we propose an efficient privacy-preserving k-Means clustering algorithm. First, we provide a new secure comparison protocol that performs the fast comparison of encrypted data. Second, we select center points by considering the distribution of the entire data. Finally, we show from our performance analysis that our clustering algorithm achieves about 300% better performance on average than the existing algorithm.
An exhaust gas recirculation (EGR) valve position control system requires fast response without overshoot, but the low control frequency limits control bandwidth and results in poor position response. A novel EGR valve position control scheme is proposed to improve the position response at low control frequency. This is based on the feedforward controller, but the feedforward control loop is implemented without the position pattern generator or derivative. The proposed method estimates the acceleration command through the relationship between the position controller output, the speed command and the speed limiter, and compensates the cascaded proportional-proportional integral (P-PI) controller. In this method, many operations are not required and noise due to derivative is not generated. This method can improve the position response without much computation and derivative noise at the low control frequency. Experimental results are presented to verify the feasibility of the proposed position control algorithm.
This paper proposes a method for minimizing the inductor current ripple of a DC–DC converter in a two-stage power conversion system consisting of a grid-connected PWM converter and an interleaved multiphase three-level DC–DC converter. To reduce the output voltage ripple, the three-level DC–DC converter is configured in parallel and operated interleaved. However, a circulating current generated by the interleaved operation increases the inductor current ripple of each DC–DC converter and causes system loss and inductor saturation. In this paper, the inductor and output current ripple of the interleaved three-phase three-level DC–DC converter is mathematically analyzed and the effect of the DC–DC converter’s duty ratio and output voltage on each current ripple is described. Based on this analysis, a method is proposed for controlling the optimal DC link voltage through the PWM converter, so that the DC–DC converter is controlled with the duty ratio that minimizes the inductor current ripple. The simulation and experimental results under various operating conditions are presented to verify the feasibility of the proposed control method.
This paper describes a method for reducing the common-mode voltage in a seven-phase brushless DC motor (BLDC) drive. The conventional interleaved method used in the three-phase inverter system is extended and applied. The proposed phase-phase interleaved method is studied to apply the six-phase excitation method for controlling the seven-phase BLDC. The six-phase switching functions related with modulation index (MI) and interleaved angle are obtained, and the average of the common-mode voltage is derived mathematically. The proposed control method reduces the common-mode voltage generation by applying the optimal interleaved angle according to MI. The proposed method is verified by experimental results.