Mathieu Falbriard

Mr. Mathieu Falbriard


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
MFMathieu Falbriard
Mathieu Falbriard
FMFrédéric Meyer
Frédéric Meyer
BMBenoit Mariani
Benoit Mariani
GMGrégoire P. Millet
Grégoire P. Millet
KAKamiar Aminian
Kamiar Aminian
The aim of this study was to assess the performance of different kinematic features measured by foot-worn inertial sensors for detecting running gait temporal events (e.g., initial contact, terminal contact) in order to estimate inner-stride phases duration (e.g., contact time, flight time, swing time, step time). Forty-one healthy adults ran multiple trials on an instrumented treadmill while wearing one inertial measurement unit on the dorsum of each foot. Different algorithms for the detection of initial contact and terminal contact were proposed, evaluated and compared with a reference-threshold on the vertical ground reaction force. The minimum of the pitch angular velocity within the first and second half of a mid-swing to mid-swing cycle were identified as the most precise features for initial and terminal contact detection with an inter-trial median ± IQR precision of 2 ± 1 ms and 4 ± 2 ms respectively. Using these initial and terminal contact features, this study showed that the ground contact time, flight time, step and swing time can be estimated with an inter-trial median ± IQR bias less than 12 ± 10 ms and the a precision less than 4 ± 3 ms. Finally, this study showed that the running speed can significantly affect the biases of the estimations, suggesting that a speed-dependent correction should be applied to improve the system’s accuracy.

13 February 2020 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
MFMathieu Falbriard
Mathieu Falbriard
FMFrédéric Meyer
Frédéric Meyer
BMBenoît Mariani
Benoît Mariani
GMGregoire Millet
Gregoire Millet
KAKamiar Aminian
Kamiar Aminian
This study aimed to introduce and validate a new method to estimate and correct the orientation drift measured from foot-worn inertial sensors. A modified strap-down integration (MSDI) was proposed to decrease the orientation drift, which, in turn, was further compensated by estimation of the joint center acceleration (JCA) of a two-segment model of the foot. This method was designed to fit the different foot strike patterns observed in running and was validated against an optical motion-tracking system during level treadmill running at 8, 12, and 16 km/h. The sagittal and frontal plane angles obtained from the inertial sensors and the motion tracking system were compared at different moments of the ground contact phase. The results obtained from 26 runners showed that the foot orientation at mean stance was estimated with an accuracy (inter-trial median ± IQR) of 0.4 ± 3.8° and a precision (inter-trial precision median ± IQR) of 3.0 ± 1.8°. The orientation of the foot shortly before initial contact (IC) was estimated with an accuracy of 2.0 ± 5.9° and a precision of 1.6 ± 1.1°; which is more accurate than commonly used zero-velocity update methods derived from gait analysis and not explicitly designed for running. Finally, the study presented the effect initial and terminal contact (TC) detection errors have on the orientation parameters reported.

22 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
GPGaëlle Prigent
Gaëlle Prigent
Kamiar AminianKamiar Aminian
Kamiar Aminian
TRTiago Rodrigues
Tiago Rodrigues
JVJean-Marc Vesin
Jean-Marc Vesin
GMGregoire Millet
Gregoire Millet
APAnisoara Paraschiv-Ionescu
Anisoara Paraschiv-Ionescu
Recent advances in wearable technologies integrating multi-modal sensors have enabled the in-field monitoring of several physiological metrics. In sport applications, wearable devices have been widely used to improve performance while minimizing the risk of injuries and illness. The objective of this project is to estimate breathing rate (BR) from respiratory sinus arrhythmia (RSA) using heart rate (HR) recorded with a chest belt during physical activities, yielding additional physiological insight without the need of an additional sensor. Thirty-one healthy adults performed a run at increasing speed until exhaustion on an instrumented treadmill. RR intervals were measured using the Polar H10 HR monitoring system attached to a chest belt. A metabolic measurement system was used as a reference to evaluate the accuracy of the BR estimation. The evaluation of the algorithms consisted of exploring two pre-processing methods (band-pass filters and relative RR intervals transformation) with different instantaneous frequency tracking algorithms (short-term Fourier transform, single frequency tracking, harmonic frequency tracking and peak detection). The two most accurate BR estimations were achieved by combining band-pass filters with short-term Fourier transform, and relative RR intervals transformation with harmonic frequency tracking, showing 5.5% and 7.6% errors, respectively. These two methods were found to provide reasonably accurate BR estimation over a wide range of breathing frequency. Future challenges consist in applying/validating our approaches during in-field endurance running in the context of fatigue assessment.

6 May 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MFMathieu Falbriard
Mathieu Falbriard
GHGrégory Huot
Grégory Huot
MJMathieu Janier
Mathieu Janier
RCRajasundar Chandran
Rajasundar Chandran
MRMichael Rechsteiner
Michael Rechsteiner
KAKamiar Aminian
Kamiar Aminian
Humanitarian actors involved in physical rehabilitation, such as the International Committee of the Red Cross (ICRC), usually provide their beneficiaries with lower-limb prostheses comprising Solid Ankle Cushion Heel (SACH) feet as these are considered appropriate (price, durability, low profile to fit a majority of patients, appearance) and reliable for all ambulation levels. However, individuals in low-resource settings having higher ambulation abilities would greatly benefit from dynamic prosthetic feet with improved biomechanics and energy storage and release. Some attempts tried to address this increasing need (e.g. Niagara Foot) but most products proposed by large manufacturers often remain unaffordable and unsuitable to the context of low-resource settings. The design requirements and a price target were defined in partnership with the ICRC according to their initial assessment and used as a starting point for the development process and related technological choices. Numerical simulation and modeling were used to work on the design and to determine the required materials properties (mechanical, chemical, wear), and a cost modeling tool was used to select suitable materials and relevant processing routes (price vs. performance). A prosthetic foot comprising an internal keel made of composite materials, a filling foam, and a cosmetic shell with a foot shape was developed. Manufacturing processes meeting the cost criteria were identified and prototype feet were produced accordingly. These were successfully tested using a compression testing system before gait analyses were performed in the laboratory with non-amputees wearing testing boots. After validation in laboratory conditions, the prototype foot was tested in the field (Vietnam) with 11 trans-tibial unilateral amputees, who showed an increased mobility compared with the SACH foot. The collaboration of different research fields led to the development of a prosthetic foot which met the technical requirements determined by the ICRC’s specific needs in its field of operation. The materials and selected production processes led to a manufacturing cost of less than 100 USD per part.

1 February 2018 in Gait & Posture
Verified
Journal Article
Closed access
FMFrédéric Meyer
Frédéric Meyer
MFMathieu Falbriard
Mathieu Falbriard
Kamiar AminianKamiar Aminian
Kamiar Aminian
GMGregoire Millet
Gregoire Millet

8 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MFMathieu Falbriard
Mathieu Falbriard
MMMaurice Mohr
Maurice Mohr
Kamiar AminianKamiar Aminian
Kamiar Aminian
This research aimed to determine whether: (1) shoe-worn magnetic and inertial sensors can be used to detect hurdle clearance and identify the leading leg in 400-m hurdles, and (2) to provide an analysis of the hurdlers’ spatiotemporal parameters in the intervals defined by the hurdles’ position. The data set is composed of MIMU recordings of 15 athletes in a competitive environment. The results show that the method based on the duration of the flight phase was able to detect hurdle clearance and identify the leading leg with 100% accuracy. Moreover, by combining the swing phase duration with the orientation of the foot, we achieved, in unipedal configuration, 100% accuracy in hurdle clearance detection, and 99.7% accuracy in the identification of the leading leg. Finally, this study provides statistical evidence that contact time significantly increases, while speed and step frequency significantly decrease with time during 400 m hurdle races.