Yossra Trabik

Dr. Yossra Trabik

Assistant Professor Pharmaceutical Analytical Chemistry department Faculty of Pharmacy ASU
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2022 in Processes
Verified
Journal Article
Open access
PDF file
FAFatma Abouelenien
Fatma Abouelenien
Yossra TrabikYossra Trabik
Yossra Trabik
Mustafa ShukryMustafa Shukry
Mustafa Shukry
MEmohamed elsharnouby
mohamed elsharnouby
Samy sayedSamy sayed
Samy sayed
NENagham Rafeek Elsaidy
Nagham Rafeek Elsaidy
Slaughterhouse wastewater (SHWW) is classified as industrial waste, which is exceptionally harmful to the environment due to its high content of biological oxygen demand (BOD), chemical oxygen demand (COD), and suspended solids, which result from high organic and nutrient loading. This study used a pilot system to treat SHWW from the Kafrelsheikh Governorate slaughterhouse, which includes a three-step process. It started with sedimentation, then coagulation and flocculation using different concentrations of each: natural zeolites (Z) and Psidium guajava-leaf powder (GLP) as green and environmentally friendly agents, and alum (A) as an inorganic coagulant. The final step was filtration with physically treated rice straw (RS). Each step was judged separately by measuring the removal percentages of each analyzed pollutant, and finally, the overall process was evaluated using the same method. A jar test was used to determine the best concentration of each coagulant used. The measured pollutants were physico-chemical, such as COD, BOD, TSS, TKN, and turbidity. The bacteriological examination included TBC, TCC, and FC. The jar-test results determined that Z 1200 mg/L SHWW, GLP 1 g/L, and A 6 g/L were the best concentrations for each coagulant used. In the coagulation step, GLP 1 g/L gave the highest removal percentage of TSS, TKN, EC, and turbidity, while Z 1200 mg/L gave the highest removal percentage of COD, TDS, TBC, and TCC. From these results, it was concluded that a natural coagulant performs better than a chemical one. Finally, judging the overall pilot test system after applying the filtration with physically treated RS, we found that the best removal efficiencies were obtained from Z 1200 mg/L combined with RS. This combination resulted in 90.58, 83.47, 88.75, 54.89, 21.39, 34.49, 84.16, 99.98, and 99.93 removal percentages for BOD, COD, TSS, TKN, EC, turbidity, TBC, and TCC, respectively.

31 December 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
Miriam AyadMiriam Ayad
Miriam Ayad
Yossra TrabikYossra Trabik
Yossra Trabik
MAMona Abdelrahman
Mona Abdelrahman
Nermine FaresNermine Fares
Nermine Fares
NMNancy Magdy
Nancy Magdy
Antimicrobial resistance (AMR) is a neglected issue that poses a serious global threat to public health, causing long-term negative consequences at both humanitarian and economic levels. Herein, we report an unprecedented economic fabrication method of seven potentiometric screen-printed sensors for the ultra-trace determination of gemifloxacin (GEMI) as a model of the fluoroquinolones antibiotics deeply involved in the growing AMR problem. Sensors were constructed by depositing homemade carbon ink on a recycled X-ray sheet, patterned using stencils printed with an office printer in simple, cost-effective steps requiring no sophisticated equipment. Four sensors were modified using carbon quantum dots (CQDs) synthesized from dextrose through a single-step method. Sensors exhibited a linear response in the concentration ranges 10−5–10−2 M (sensors 1, 3 and 4), 10−6–10−3 M (sensor 2) and 10−6–10−2 M (sensors 5, 6 and 7). LOD allowed tracing of the target drug at a nano-molar level down to 210 nM. GEMI was successfully determined in pharmaceutical formulations and different water samples without any pretreatment steps with satisfactory recovery (96.93–105.28% with SD values < 3). All sensors revealed a long lifetime of up to several months and are considered promising tools for monitoring water quality and efficiency of water treatment measures.

10 April 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
LHLobna Harazni
Lobna Harazni
AEAmira M. El-Kosasy
Amira M. El-Kosasy
Yossra TrabikYossra Trabik
Yossra Trabik
Three novel fluconazole (FLU) selective electrodes were investigated with di-octyl phthalate as a plasticizer in a polymeric matrix of polyvinyl chloride and 2-hydroxypropyl-β-cyclodextrin as an ionophore. The potentiometric strategy was based on functionalized magnetic iron oxide particles. A mixture of equal volumes of 1 × 10−2 M FLU and 1 × 10−2 M KCl was used as an internal reference solution for sensor 1. An aqueous dispersion of magnetic micro iron oxide particles was introduced into an internal reference solution for sensor 2, whereas an aqueous dispersion of magnetic nano iron oxide particles was introduced for sensor 3. By applying a magnetic field, the iron oxide particles could be attached to the surface of an ionophore-free polymeric membrane. FLU was accurately determined in spiked human plasma and spiked cow milk.

11 May 2022 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
NFNesma M Fahmy
Nesma M Fahmy
HAHind A Abdullatif
Hind A Abdullatif
AMAdel M Michael
Adel M Michael
MAMiriam F Ayad
Miriam F Ayad
Yossra TrabikYossra Trabik
Yossra Trabik
Background: Over the last few years, mathematical manipulation has proved to be a very powerful means of successfully resolving severely overlapped spectra for various multicomponent mixtures. Objective: Smart and environmentally friendly spectrophotometric determination approaches were used for two binary mixtures of fixed dose veterinary injections containing flunixin meglumine (FLU) combined with either florfenicol (FLR), or oxytetracycline HCl (OXY). Methods: Regarding the first mixture, both FLU and FLR were determined by three successive resolution techniques, which were; constant multiplication coupled with spectrum subtraction (CM-SS), derivative ratio (DD1), and ratio difference (RD), and two progressive resolution techniques which were absorbance subtraction (AS) and amplitude modulation (AM). Also, graphical representation of concentration of the two drugs through concentration value (CNV) method was also applied. Concerning the second mixture, both FLU and OXY showed severely overlapped spectra and a comparative study was conducted for the determination of each drug by constant center (CC), ratio subtraction via amplitude difference coupled with spectrum subtraction (RS/AD-SS), constant value via amplitude difference (CV-AD), and advanced concentration value (ACV) methods. Results: Calibration graphs of the first mixture were linear over the range 5–40 µg/mL for FLU, and 3–40 µg/mL for FLR. The proposed methods overcame the problem of the overlapped spectra and the presence of a minor component in the mixture. Regarding the second mixture, calibration graphs were linear over the range 2.5–24 µg/mL for FLU and 4–28 µg/mL for OXY. Conclusion: The proposed methods were successfully validated as per International Council for Harmonization (ICH) guidelines. The obtained results were statistically compared with the official or reported methods, showing no significant difference concerning accuracy and precision. The methods were evaluated for greenness by three different assessment tools: NEMI, analytical ecoscale, and GAPI. Highlights: The methods were successfully applied for the simultaneous determination of the two combinations in synthetic mixtures and their marketed antibiotic veterinary injections: Megluflor® and Floxon®.

28 February 2022 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
PDF file
SESarah Elnadi
Sarah Elnadi
SASamah Abdalsabour
Samah Abdalsabour
MFMaha Farouk
Maha Farouk
Yossra TrabikYossra Trabik
Yossra Trabik
Background: Green Fourier transform infrared (FTIR) spectroscopy, using potassium bromide (KBr) disc technique, eliminates the consumption of hazardous chemicals. Spectrofluorimetry for drugs that have native fluorescence. Mean centering of ratio spectra (MCRS) analysing overlapped spectra without preliminary separation.Objective: Three simple, accurate, and sensitive methods have been developed and validated for the determination of canagliflozin (CANA); one is a stability-indicating method for CANA and metformin (MET) determination.Methods: Method A is FTIR using a KBr disc for CANA determination measuring alkyl halide C–F peak area centered on 1230/cm. Method B is spectrofluorimetry using Δ λ = 50 nm synchronous mode at a peak maximum of 291.8 nm for CANA determination using methanol as solvent. Method C is a stability-indicating MCRS method measuring the peak amplitude of CANA and MET at 306.2 and 246.6 nm, respectively, in their mixture with complete CANA oxidation degradation.Results: The linear ranges were: FTIR spectroscopy, 1.50–24.70 μg/mg CANA; spectrofluorimetry, 100.00–600.00 ng/mL CANA; and MCRS, 1.00–25.00 μg/mL CANA and 1–30 μg/mL MET.Conclusion: All results were statistically compared with a reported method: no significant difference was observed.Highlights: The proposed methods can be used efficiently for routine analysis in QC laboratories. A green FTIR method utilizes only one reagent, KBr. Spectrofluorimetry using a constant wavelength synchronous scan of CANA native fluorescence in nanogram concentrations overcomes conventional excitation/emission spectra drawbacks and proves that the solvent effect in the fluorescence intensity differs according to concentration used. Stability-indicating MCRS determines the studied drugs in bulk, pharmaceutical formulations, accelerated and long-term stability study samples.

1 January 2024 in Reviews in Analytical Chemistry
Verified
Journal Article
Open access
PDF file
Yossra TrabikYossra Trabik
Yossra Trabik
RIReham Abd El-Aziz Ismail
Reham Abd El-Aziz Ismail
MAMiriam Farid Ayad
Miriam Farid Ayad
LHLobna Abd El-Aziz Hussein
Lobna Abd El-Aziz Hussein
AMAmr M. Mahmoud
Amr M. Mahmoud
In this work, a solid-state electrochemical sensor relying on potentiometric transduction was constructed and optimized to detect Bosentan (BOS) in its pharmaceutical dosage form and human plasma. BOS is useful in pulmonary hypertension management as a nonselective endothelin receptor antagonist. A printed circuit board has been constructed and used as a substrate for microfabricated Cu electrodes. In comparison to a microfabricated control (Cu/ISM) electrode, the sensor potential signal drift was enhanced, and the response time was reduced by using multi-walled carbon nanotubes (MWCNTs) as an ion-to-electron transducer layer. According to IUPAC requirements, the suggested BOS sensors have been electrochemically characterized, and the linear dynamic range is (1.0 × 10 −8 to 1.0 × 10 −5 ) M with a limit of detection of 6.28 × 10 −9 M and 6.12 × 10 −9 M for MWCNT-based sensor (Cu/CNT-NC/ISM) and control sensor (Cu/ISM), respectively. The described sensors have been used successfully to selectively determine BOS in dosage form and human plasma without any pre-treatment steps.