The ambitious United Nations Sustainable Development Goal for 2030 to “leave no one behind” concerning safe drinking water calls for the development of universally applicable and affordable decentralized treatment systems to provide safe drinking water. Published results suggest that well-designed biological sand filters (BSFs) amended with metallic iron (Fe0-BSFs) have the potential to achieve this goal. Fe0-BSFs quantitatively remove pathogens and a myriad of chemical pollutants. The available data were achieved under various operating conditions. A comparison of independent research results is almost impossible, especially because the used Fe0 materials are not characterized for their intrinsic reactivity. This communication summarizes the state-of-the-art knowledge on designing Fe0-BSFs for households and small communities. The results show that significant research progress has been made on Fe0-BSFs. However, well-designed laboratory and field experiments are required to improve the available knowledge in order to develop the next generation of adaptable and scalable designs of Fe0-BSFs in only two years. Tools to alleviate the permeability loss, the preferential flow, and the use of exhausted filters are presented.
This study characterizes the decrease of the hydraulic conductivity (permeability loss) of a metallic iron-based household water filter (Fe0 filter) for a duration of 12 months. A commercial steel wool (SW) is used as Fe0 source. The Fe0 unit containing 300 g of SW was sandwiched between two conventional biological sand filters (BSFs). The working solution was slightly turbid natural well water polluted with pathogens (total coliform = 1950 UFC mL−1) and contaminated with nitrate ([NO3−] = 24.0 mg L−1). The system was monitored twice per month for pH value, removal of nitrate, coliforms, and turbidity, the iron concentration, as well as the permeability loss. Results revealed a quantitative removal of coliform (>99%), nitrate (>99%) and turbidity (>96%). The whole column effluent depicted drinking water quality. The permeability loss after one year of operation was about 40%, and the filter was still producing 200 L of drinking water per day at a flow velocity of 12.5 L h−1. A progressive increase of the effluent pH value was also recorded from about 5.0 (influent) to 8.4 at the end of the experiment. The effluent iron concentration was constantly lower than 0.2 mg L−1, which is within the drinking-water quality standards. This study presents an affordable design that can be one-to-one translated into the real world to accelerate the achievement of the UN Sustainable Development Goals for safe drinking water.
There are many factors to consider for the design of appropriate water treatment systems including: cost, the concentration and type of biological and/or chemical contamination, concentration limits at which contaminant(s) are required to be removed, required flow rate, level of local expertise for on-going maintenance, and social acceptance. An ideal technology should be effective at producing clean, potable water; however it must also be low-cost, low-energy (ideally energy-free) and require low-maintenance. The use of packed beds containing metallic iron (Fe0 filters) has the potential to become a cheap widespread technology for both safe drinking water provision and wastewater treatment. Fe0 filters have been intensively investigated over the past two decades, however, sound design criteria are still lacking. This article presents an overview of the design of Fe0 filters for decentralized water treatment particularly in the developing world. A design for safe drinking water to a community of 100 people is also discussed as starting module. It is suggested that Fe0 filters have the potential for significant worldwide applicability, but particularly in the developing world. The appropriate design of Fe0 filters, however, is site-specific and dependent upon the availability of local expertise/materials.
Metallic iron (Fe0) corrosion under immersed conditions (Fe0/H2O system) has been used for water treatment for the past 170 years. Fe0 generates solid iron corrosion products (FeCPs) which are known to in situ coat the surface of aggregates, including granular activated carbon (GAC), gravel, lapillus, manganese oxide (MnO2), pyrite (FeS2), and sand. While admixing Fe0 and reactive aggregates to build hybrid systems (e.g., Fe0/FeS2, Fe0/MnO2, Fe0/sand) for water treatment, it has been largely overlooked that these materials would experience reactivity loss upon coating. This communication clarifies the relationships between aggregate addition and the sustainability of Fe0/H2O filtration systems. It is shown that any enhanced contaminant removal efficiency in Fe0/aggregate/H2O systems relative to the Fe0/H2O system is related to the avoidance/delay of particle cementation by virtue of the non-expansive nature of the aggregates. The argument that aggregate addition sustains any reductive transformation of contaminants mediated by electrons from Fe0 is disproved by the evidence that Fe0/sand systems are equally more efficient than pure Fe0 systems. This demonstration corroborates the concept that aqueous contaminant removal in iron/water systems is not a process mediated by electrons from Fe0. This communication reiterates that only hybrid Fe0/H2O filtration systems are sustainable.
22 March 2024 in Journal of Environmental Management
Quiescent batch experiments were conducted to evaluate the influences of Cl-, F-, HCO3-, HPO42-, and SO42- on the reactivity of metallic iron (Fe0) for water remediation using the methylene blue (MB) method. Strong discoloration of MB indicates high availability of solid iron corrosion products (FeCPs). Tap water was used as an operational reference. Experiments were carried out in graduated test tubes (22 mL) for up to 45 d, using 0.1 g of Fe0 and 0.5 g of sand. Operational parameters investigated were (i) equilibration time (0-45 d), (ii) 4 different types of Fe0, (iii) anion concentration (10 values), and (iv) use of MB and Orange II (O-II). The degree of dye discoloration, the pH, and the iron concentration were monitored in each system. Relative to the reference system, HCO3- enhanced the extent of MB discoloration, while Cl-, F-, HPO42-, and SO42- inhibited it. A different behavior was observed for O-II discoloration: in particular, HCO3- inhibited O-II discoloration. The increased MB discoloration in the HCO3- system was justified by considering the availability of FeCPs as contaminant scavengers, pH increase, and contact time. The addition of any other anion initially delays the availability of FeCPs. Conflicting results in the literature can be attributed to the use of inappropriate experimental conditions. The results indicate that the application of Fe0-based systems for water remediation is a highly site-specific issue which has to include the anion chemistry of the water.
Permeable reactive barriers (PRBs) containing metallic iron (Fe0) as reactive materials are currently considered as an established technology for groundwater remediation. Fe0 PRBs have been introduced by a field demonstration based on the fortuitous observation that aqueous trichloroethylenes are eliminated in Fe0-based sampling vessels. Since then, Fe0 has been tested and used for treating various biological (e.g. bacteria, viruses) and chemical (organic and inorganic) contaminants from polluted waters. There is a broad consensus on the view that “reactivity loss” and “permeability loss” are the two main problems hampering the design of sustainable Fe0 systems. However, the view that Fe0 is a reducing agent (electron donor) under environmental conditions should be regarded as a distortion of Corrosion Science. This is because it has been long established that aqueous iron corrosion is a spontaneous process and results in the Fe0 surface being shielded by an oxide scale. The multi-layered oxide scale acts as a conduction barrier for electrons from Fe0. Accordingly, “reactivity loss”, defined as reduced electron transfer to contaminants, must be revisited. On the other hand, because “stoichiometric” ratios were considered while designing the first generation of Fe0 PRBs (Fe0 as reductant), “permeability loss” should also be revisited. The aim of this communication is to clarify this issue and reconcile a proven efficient technology with its scientific roots (i.e. corrosion science).