The ambitious United Nations Sustainable Development Goal for 2030 to “leave no one behind” concerning safe drinking water calls for the development of universally applicable and affordable decentralized treatment systems to provide safe drinking water. Published results suggest that well-designed biological sand filters (BSFs) amended with metallic iron (Fe0-BSFs) have the potential to achieve this goal. Fe0-BSFs quantitatively remove pathogens and a myriad of chemical pollutants. The available data were achieved under various operating conditions. A comparison of independent research results is almost impossible, especially because the used Fe0 materials are not characterized for their intrinsic reactivity. This communication summarizes the state-of-the-art knowledge on designing Fe0-BSFs for households and small communities. The results show that significant research progress has been made on Fe0-BSFs. However, well-designed laboratory and field experiments are required to improve the available knowledge in order to develop the next generation of adaptable and scalable designs of Fe0-BSFs in only two years. Tools to alleviate the permeability loss, the preferential flow, and the use of exhausted filters are presented.
A critical survey of the abundant literature on environmental remediation and water treatment using metallic iron (Fe0) as reactive agent raises two major concerns: (i) the peculiar properties of the used materials are not properly considered and characterized, and, (ii) the literature review in individual publications is very selective, thereby excluding some fundamental principles. Fe0 specimens for water treatment are typically small in size. Before the advent of this technology and its application for environmental remediation, such small Fe0 particles have never been allowed to freely corrode for the long-term spanning several years. As concerning the selective literature review, the root cause is that Fe0 was considered as a (strong) reducing agent under environmental conditions. Subsequent interpretation of research results was mainly directed at supporting this mistaken view. The net result is that, within three decades, the Fe0 research community has developed itself to a sort of modern knowledge system. This communication is a further attempt to bring Fe0 research back to the highway of mainstream corrosion science, where the fundamentals of Fe0 technology are rooted. The inherent errors of selected approaches, currently considered as countermeasures to address the inherent limitations of the Fe0 technology are demonstrated. The misuse of the terms “reactivity”, and “efficiency”, and adsorption kinetics and isotherm models for Fe0 systems is also elucidated. The immense importance of Fe0/H2O systems in solving the long-lasting issue of universal safe drinking water provision and wastewater treatment calls for a science-based system design.
Calcium sulfate exists in three forms, namely dihydrate or gypsum (CaSO4·2H2O), anhydrite (CaSO4), and hemihydrate or bassanite (CaSO4·0.5H2O) depending on temperature, pressure, pH, and formation conditions. The formation of calcium sulfates occurs widely in nature and in many engineering settings. Herein, a dataset containing the experimental solubility data of calcium sulfate minerals, i.e., gypsum and anhydrite, in aqueous solutions is presented. The compiled dataset contains calcium sulfates solubility values extracted from 42 papers published between 1906 and 2019. The dataset can be used for various scientific and engineering purposes such as environmental applications (e.g., gas treatment, wastewater treatment, and chemical disposal), geotechnical applications (e.g., clay-sulfate rock swelling), separation processes (e.g., crystallization, extractive distillation, and seawater desalination), and electrochemical processes (e.g., corrosion and electrolysis).
The technology of using metallic iron (Fe0) for in situ generation of iron oxides for water treatment is a very old one. The Fe0 remediation technology has been re-discovered in the framework of groundwater remediation using permeable reactive barriers (PRBs). Despite its simplicity, the improvement of Fe0 PRBs is fraught with difficulties regarding their operating modes. The literature dealing with Fe0 remediation contains ambiguities regarding its invention and its development. The present paper examines the sequence of contributions prior to the advent of Fe0 PRBs in order to clarify the seemingly complex picture. To achieve this, the current paper addresses the following questions: (i) What were the motivations of various authors in developing their respective innovations over the years?, (ii) what are the ancient achievements which can accelerate progress in knowledge for the development of Fe0 PRBs?, and (iii) was Fe0 really used for the removal of organic species for the first time in the 1970s? A careful examination of ancient works reveals that: (i) The wrong questions were asked during the past three decades, as Fe0 was premised as a reducing agent, (ii) credit for using Fe0 for water treatment belongs to no individual scientist, and (iii) credit for the use of Fe0 in filtration systems for safe drinking water provision belongs to scientists from the 1850s, while credit for the use of Fe0 for the removal of aqueous organic species does not belong to the pioneers of the Fe0 PRB technology. However, it was these pioneers who exploited Fe0 for groundwater remediation, thereby extending its potential. Complementing recent achievements with the chemistry of the Fe0/H2O system would facilitate the design of more sustainable Fe0-remediation systems.
Solid iron corrosion products (FeCPs), continuously generated from iron corrosion in Fe0-based permeable reactive barriers (PRB) at pH > 4.5, can lead to significant porosity loss and possibility of system’s failure. To avoid such failure and to estimate the long-term performance of PRBs, reliable models are required. In this study, a mathematical model is presented to describe the porosity change of a hypothetical Fe0-based PRB through-flowed by deionized water. The porosity loss is solely caused by iron corrosion process. The new model is based on Faraday’s Law and considers the iron surface passivation. Experimental results from literature were used to calibrate the parameters of the model. The derived iron corrosion rates (2.60 mmol/(kg day), 2.07 mmol/(kg day) and 1.77 mmol/(kg day)) are significantly larger than the corrosion rate used in previous modeling studies (0.4 mmol/(kg day)). This suggests that the previous models have underestimated the impact of in-situ generated FeCPs on the porosity loss. The model results show that the assumptions for the iron corrosion rates on basis of a first-order dependency on iron surface area are only valid when no iron surface passivation is considered. The simulations demonstrate that volume-expansion by Fe0 corrosion products alone can cause a great extent of porosity loss and suggests careful evaluation of the iron corrosion process in individual Fe0-based PRB.
Travel-time based hydraulic tomography is a promising method to characterize heterogeneity of porous-fractured aquifers. However, there is inevitable noise in field-scale experimental data and many hydraulic signal travel times, which are derived from the pumping test’s first groundwater level derivative drawdown curves and are strongly influenced by noise. The required data processing is thus quite time consuming and often not accurate enough. Therefore, an effective and accurate de-noising method is required for travel time inversion data processing. In this study, a series of hydraulic tomography experiments were conducted at a porous-fractured aquifer test site in Goettingen, Germany. A numerical model was built according to the site’s field conditions and tested based on diagnostic curve analyses of the field experimental data. Gaussian white noise was then added to the model’s calculated pumping test drawdown data to simulate the real noise in the field. Afterward, different de-noising methods were applied to remove it. This study has proven the superiority of the wavelet de-noising approach compared with several other filters. A wavelet de-noising method with calibrated mother wavelet type, de-noising level, and wavelet level was then determined to obtain the most accurate travel time values. Finally, using this most suitable de-noising method, the experimental hydraulic tomography travel time values were calculated from the de-noised data. The travel time inversion based on this de-noised data has shown results consistent with previous work at the test site.