Srečko Glodež

Prof. Srečko Glodež

University of Maribor, Maribor, Slovenia
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2020 in International Journal of Technology and Design Education
Verified
Journal Article
Closed access
PDF file
AŠAndrej Šafhalter
Andrej Šafhalter
SGSrečko Glodež
Srečko Glodež
PŠPAYMENT (VS: 894419) PBE Conference Andrej Šorgo
PAYMENT (VS: 894419) PBE Conference Andrej Šorgo
MVMateja Ploj Virtič
Mateja Ploj Virtič

14 July 2020 in Metals
Verified
Journal Article
Open access
PDF file
MUMiran Ulbin
Miran Ulbin
Matej BorovinšekMatej Borovinšek
Matej Borovinšek
MVMatej Vesenjak
Matej Vesenjak
SGSrečko Glodež
Srečko Glodež
In this study, a computational fatigue analysis of topology optimised auxetic cellular structures made of Selective Laser Melting (SLM) AlSi10Mg alloy is presented. Structures were selected from the Pareto front obtained by the multi-objective optimisation. Five structures with different negative Poisson’s ratios were considered for the parametric numerical analysis, where the fillet radius of cellular struts has been chosen as a parameter. The fatigue life of the analysed structures was determined by the strain–life approach using the Universal Slope method, where the needed material parameters were determined according to the experimental results obtained by quasi-static unidirectional tensile tests. The obtained computational results have shown that generally less auxetic structures tend to have a better fatigue life expectancy. Furthermore, the fillet radius has a significant impact on fatigue life. In general, the fatigue life decreases for smaller fillet radiuses (less than 0.3 mm) as a consequence of the high-stress concentrations, and also for larger fillet radiuses (more than 0.6 mm) due to the moving of the plastic zone away from the edge of the cell connections. The obtained computational results serve as a basis for further investigation, which should be focused on the experimental testing of the fabricated auxetic cellular structures made of SLM AlSi10Mg alloy under cyclic loading conditions.

24 December 2020 in Advances in Production Engineering & Management
Verified
Journal Article
Closed access
BPB. Polanec
B. Polanec
JKJ. Kramberger
J. Kramberger
SGSrečko Glodež
Srečko Glodež
The purpose of this article is to give a general overview of the production technologies of stents with consideration of their design and materials. Since the beginning of the use of stents in medicine for atherosclerosis treatment, their development has changed rapidly. Various stents have also been developed with the development of materials science, treatment techniques and new manufacturing processes. In this way the development has shifted from the initial bare-metal stents (BMS), to drug-eluting stents (DES) and bio-resorbable stents (BRS), which are made of biodegradable polymers or metals. Various studies agree that it will be necessary to further review the experimentally obtained material properties with analytical and numerical studies. Here, the computational modelling (Finite element analysis - FEA and Computational fluid dynamics - CFD) was found as a valuable tool when evaluating stent mechanics and optimizing stent design. The development of the stent manufacturing technologies has also changed and been supplemented over the years. Nowadays, 3D printing could be an exciting manufacturing method to produce polymeric bio-materials, suitable for the latest generation of bio-degradable stents applications.

22 January 2022 in Polymers
Verified
Journal Article
Open access
PDF file
BTBoštjan Trobentar
Boštjan Trobentar
MHMatija Hribersek
Matija Hribersek
SKSimon Kulovec
Simon Kulovec
SGSrečko Glodež
Srečko Glodež
ABAleš Belšak
Aleš Belšak
In this study, an acoustic behaviour of S-polymer gears made of the material combination POM/PA66 was investigated and compared to the standardised involute gears (E-gears). Basic evaluating characteristics included noise during operation, which is of particular significance when noise reduction is expected. The measured signals were analysed in time and frequency domains and the levels of acoustic activity were compared. The experimental results have shown that the sound pressure level of both E- and S-polymer gears are proportional to the torque. However, the comprehensive noise evaluation has shown some advantages of S-polymer gears if compared to the E-polymer gears. In that respect, S-polymer gears were found more appropriate for noise reduction of gear drive systems in the case of normal loading and typical drive speed. Future studies in the operating behaviour of S-polymer gears could also cover noise evaluation using new methods of sound signal analysis at different temperatures of gears.

13 December 2019 in Forests
Verified
Journal Article
Open access
PDF file
GFGorazd Fajdiga
Gorazd Fajdiga
DRDenis Rajh
Denis Rajh
BNBranko Nečemer
Branko Nečemer
SGSrečko Glodež
Srečko Glodež
Matjaz SramlMatjaz Sraml
Matjaz Sraml
The objective of this paper is the computational and experimental study of the fracture behavior of spruce wood under quasi-static loading conditions during a three-point bending test. The experimental tests were performed on the electronic testing machine Zwick Z100 (Zwick-Roell GmbH & Co. KG, Ulm, Germany) with displacement control, according to the standard International Standard Organisation (ISO) 13061-4: 2014. The specimens were made of Norway spruce (Picea abies) wood, with dimensions of 25 mm × 25 mm in cross-section and 549 mm in length. Six tests were performed for each orientation (radial and tangential) of the wood fibres. Based on the experimental results, the computational model was created and validated by considering the mechanical responses in two different directions due to the orientation of the wood fibres. An orthotropic material model with damage evolution was selected as the computational model. The computational model was validated using the inverse procedure for the determination of the constitutive material parameters, including the damage parameters of three-point bending test specimens. A finite element method (FEM) in the framework of program package ABAQUS was used for the computational simulation, while the open code Optimax was used for the optimization procedure. Comparison between the experimental and computational force vs. the displacement response showed a very good correlation in the results for the spruce wood specimens under three-point bending tests, with Pearson′s correlation coefficient of r = 0.994 for the tangential and r = 0.988 for the radial orientation. Therefore, validation of the proposed computational model was confirmed, and can be used further in numerical simulations of the fatigue behavior of wood specimens.

13 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Žiga DonikŽiga Donik
Žiga Donik
BNBranko Nečemer
Branko Nečemer
MVMatej Vesenjak
Matej Vesenjak
SGSrečko Glodež
Srečko Glodež
JKJanez Kramberger
Janez Kramberger
Bioresorbable stents (BRS) represent the latest generation of vascular scaffolds used for minimally invasive interventions. They aim to overcome the shortcomings of established bare-metal stents (BMS) and drug-eluting stents (DES). Recent advances in the field of bioprinting offer the possibility of combining biodegradable polymers to produce a composite BRS. Evaluation of the mechanical performance of the novel composite BRS is the focus of this study, based on the idea that they are a promising solution to improve the strength and flexibility performance of single material BRS. Finite element analysis of stent crimping and expansion was performed. Polylactic acid (PLA) and polycaprolactone (PCL) formed a composite stent divided into four layers, resulting in sixteen unique combinations. A comparison of the mechanical performance of the different composite configurations was performed. The resulting stresses, strains, elastic recoil, and foreshortening were evaluated and compared to existing experimental results. Similar behaviour was observed for material configurations that included at least one PLA layer. A pure PCL stent showed significant elastic recoil and less shortening compared to PLA and composite structures. The volumetric ratio of the materials was found to have a more significant effect on recoil and foreshortening than the arrangement of the material layers. Composite BRS offer the possibility of customising the mechanical behaviour of scaffolds. They also have the potential to support the fabrication of personalised or plaque-specific stents.