Branko Nečemer

Mr. Branko Nečemer

University of Maribor, Faculty of Mechanical Engineering
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2019 in Forests
Verified
Journal Article
Open access
PDF file
GFGorazd Fajdiga
Gorazd Fajdiga
DRDenis Rajh
Denis Rajh
BNBranko Nečemer
Branko Nečemer
SGSrečko Glodež
Srečko Glodež
Matjaz SramlMatjaz Sraml
Matjaz Sraml
The objective of this paper is the computational and experimental study of the fracture behavior of spruce wood under quasi-static loading conditions during a three-point bending test. The experimental tests were performed on the electronic testing machine Zwick Z100 (Zwick-Roell GmbH & Co. KG, Ulm, Germany) with displacement control, according to the standard International Standard Organisation (ISO) 13061-4: 2014. The specimens were made of Norway spruce (Picea abies) wood, with dimensions of 25 mm × 25 mm in cross-section and 549 mm in length. Six tests were performed for each orientation (radial and tangential) of the wood fibres. Based on the experimental results, the computational model was created and validated by considering the mechanical responses in two different directions due to the orientation of the wood fibres. An orthotropic material model with damage evolution was selected as the computational model. The computational model was validated using the inverse procedure for the determination of the constitutive material parameters, including the damage parameters of three-point bending test specimens. A finite element method (FEM) in the framework of program package ABAQUS was used for the computational simulation, while the open code Optimax was used for the optimization procedure. Comparison between the experimental and computational force vs. the displacement response showed a very good correlation in the results for the spruce wood specimens under three-point bending tests, with Pearson′s correlation coefficient of r = 0.994 for the tangential and r = 0.988 for the radial orientation. Therefore, validation of the proposed computational model was confirmed, and can be used further in numerical simulations of the fatigue behavior of wood specimens.

13 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Žiga DonikŽiga Donik
Žiga Donik
BNBranko Nečemer
Branko Nečemer
MVMatej Vesenjak
Matej Vesenjak
SGSrečko Glodež
Srečko Glodež
JKJanez Kramberger
Janez Kramberger
Bioresorbable stents (BRS) represent the latest generation of vascular scaffolds used for minimally invasive interventions. They aim to overcome the shortcomings of established bare-metal stents (BMS) and drug-eluting stents (DES). Recent advances in the field of bioprinting offer the possibility of combining biodegradable polymers to produce a composite BRS. Evaluation of the mechanical performance of the novel composite BRS is the focus of this study, based on the idea that they are a promising solution to improve the strength and flexibility performance of single material BRS. Finite element analysis of stent crimping and expansion was performed. Polylactic acid (PLA) and polycaprolactone (PCL) formed a composite stent divided into four layers, resulting in sixteen unique combinations. A comparison of the mechanical performance of the different composite configurations was performed. The resulting stresses, strains, elastic recoil, and foreshortening were evaluated and compared to existing experimental results. Similar behaviour was observed for material configurations that included at least one PLA layer. A pure PCL stent showed significant elastic recoil and less shortening compared to PLA and composite structures. The volumetric ratio of the materials was found to have a more significant effect on recoil and foreshortening than the arrangement of the material layers. Composite BRS offer the possibility of customising the mechanical behaviour of scaffolds. They also have the potential to support the fabrication of personalised or plaque-specific stents.

28 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
BNBranko Nečemer
Branko Nečemer
Franc ZupanicFranc Zupanic
Franc Zupanic
Tomaž VuhererTomaž Vuherer
Tomaž Vuherer
SGSrečko Glodež
Srečko Glodež
This study presents a comprehensive experimental investigation of the high-cycle fatigue (HCF) behaviour of the ductile aluminium alloy AA 5083-H111. The analysed specimens were fabricated in the rolling direction (RD) and transverse direction (TD). The HCF tests were performed in a load control (load ratio R = 0.1) at different loading levels under the loading frequency of 66 Hz up to the final failure of the specimen. The experimental results have shown that the S–N curves of the analysed Al-alloy consist of two linear curves with different slopes. Furthermore, RD-specimens demonstrated longer fatigue life if compared to TD-specimens. This difference was about 25% at the amplitude stress 65 MPa, where the average fatigue lives 276,551 cycles for RD-specimens, and 206,727 cycles for TD-specimens were obtained. Similar behaviour was also found for the lower amplitude stresses and fatigue lives between 106 and 108 cycles. The difference can be caused by large Al6(Mn,Fe) particles which are elongated in the rolling direction and cause higher stress concentrations in the case of TD-specimens. The micrography of the fractured surfaces has shown that the fracture characteristics were typical for the ductile materials and were similar for both specimen orientations.

24 April 2025 in Structures
Verified
Journal Article
Open access
BNBranko Nečemer
Branko Nečemer
PLPatrik Lampret
Patrik Lampret
SGSrečko Glodež
Srečko Glodež

19 January 2024 in Materials
Verified
Journal Article
Open access
PDF file
BHBlaž Hanželič
Blaž Hanželič
JKJernej Kralj
Jernej Kralj
TBTonica Bončina
Tonica Bončina
BNBranko Nečemer
Branko Nečemer
JKJanez Kramberger
Janez Kramberger
SGSrečko Glodež
Srečko Glodež
The plate heat exchanger (PHE) is a component that provides heat to be transferred from hot water to domestic cold water without mixing them with high efficiency. Over the lifetime of the PHE, cyclic pressures act on the brazing points and the plates, and this may lead to fatigue failure. The fatigue behaviour of the PHE, designed using copper-brazed 316L stainless steel, was investigated in this study. First, the fatigue tests under the load ratio R = 0.1 were performed on the Vibrophore 100 testing machine to obtain the S-N curve of the analysed brazed joint. Based on the obtained experimental results, an appropriate material model of the analysed brazed joint has been created, which was validated with numerical calculation in the framework of a program code Ansys. A validated material model was then used for the subsequent numerical analysis of PHE. In order to carry out a numerical calculation using the finite element method (FEM), a three-dimensional model of the heat exchanger was created based on the previous scanning of PHE-geometry. Thereafter, the geometry was parameterised, which allowed us to perform parametric simulations (monitoring different responses depending on the input geometry). Numerical simulations were carried out in the framework of the Ansys 2023-R1 software, whereby the obtained results were analysed, and the responses were appropriately characterised according to previously determined load cases.

27 December 2024 in Polymers
Verified
Journal Article
Open access
PDF file
MZMarko Zadravec
Marko Zadravec
JKJanez Kramberger
Janez Kramberger
BNBranko Nečemer
Branko Nečemer
SGSrečko Glodež
Srečko Glodež
A comprehensive experimental investigation to understand the mechanical properties and fatigue behaviour of glass-reinforced polyamide (PA66 GF30) at different temperatures is presented in this paper. The specimens for quasi-static and fatigue testing were machined from previously extruded plates, where two orientations were considered: (i) the extrusion direction (ED) and (ii) the direction perpendicular to extrusion (PED). Both the quasi-static and fatigue tests were performed under different temperatures (22 °C and 100 °C). The fatigue tests were performed in a load control regime under pulsating loading (R = 0.1) to create S–N curves for all the temperatures and loading directions. The experimental results of the quasi-static tests showed that the test specimens manufactured in the extrusion direction have better mechanical properties when compared to those of the specimens manufactured perpendicular to the extrusion direction. Furthermore, the analysis of the quasi-static tensile test results showed that tensile strength, yield strength, and the modulus of elasticity are significantly dependent on the temperature and deteriorate when the temperature is increased from 22 °C to 100 °C. The results of the fatigue tests showed that at both the temperatures (22 °C and 100 °C), the samples produced in the direction of extrusion exhibited higher fatigue strength than those produced perpendicular to the direction of extrusion. For all the sample orientations, the fatigue strength decreased significantly with increasing temperature. The obtained experimental results could be very useful when designing and dimensioning different dynamically loaded engineering components made of PA66 GF30 subjected to high temperatures.