Natarajan Shanmugam

Mr. Natarajan Shanmugam

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2020 in IEEE Access
Verified
Journal Article
Open access
NSNatarajan Shanmugam
Natarajan Shanmugam
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
RRRajesh Rajamani
Rajesh Rajamani
Frequency Response Analysis (FRA) is an Off-line condition monitoring technique for the transformers and is successful, in diagnosing mechanical faults and inter-turn short-circuits. Only limited literature is available for On-line FRA works, and the effect of the transformer’s load on the fault diagnosing capability of FRA has not yet been analysed. Motivated by this research gap, an experimental investigation was done to analyze the effect of load on IFRA based inter-turn short-circuit diagnosis. A single-phase 1 kVA, 240V/240 V transformer supplying R and R-L loads and a three-phase 5 kVA, 440 V/440 V transformer supplying an induction motor at various load levels were tested. Inter-turn short-circuits were emulated in their windings and, the effectiveness of IFRA in diagnosing the same was investigated. Comparisons were made between the frequency response of the loaded transformers in their healthier conditions and emulated fault conditions, based on the transfer function plots and the statistical parameters. Investigations reveal that the loads alter the useful spectrum of IFRA. The frequency response of the healthier transformer itself varies based on the transformer’s load and necessitates a careful focus on the sensitive frequency spectra for effective inter-turn short-circuit diagnosis in loaded transformers.

8 March 2021 in IEEE Access
Verified
Journal Article
Open access
NSNatarajan Shanmugam
Natarajan Shanmugam
SGSrinivasan Gopal
Srinivasan Gopal
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
SBS. P. Balaji
S. P. Balaji
RRRajesh Rajamani
Rajesh Rajamani
Inter-turn short circuits within the transformer winding are diagnosable through the impulse voltage based frequency response analysis (IFRA). If the diagnosis is made Online, interruption to the power network can be avoided. However, the transformer’s load may influence the frequency response based diagnostic process, and this aspect has not yet been investigated. Motivated by this research gap, experimental investigations were carried out on a three-phase 5 kVA, 440 V/440 V Star/Delta transformer and a three-phase 315 kVA, 11 kV/433 V, Dyn11 distribution transformer, when they were supplying power to loads of different magnitudes and power factors. The influence of the load current and its power factor on the IFRA was observed under the transformer’s healthy condition and with inter-turn short circuits in one of the windings. Investigations under these different loaded conditions revealed that a signature FRA plot developed at a particular load condition cannot be directly used for assessing the condition of the transformer at a different load. Both the magnitude and the power factor of the load are found to influence the frequency response. A careful interpretation of the Frequency response of the transformer, based on its load, was found effective in detecting and locating the inter-turn shorts.

1 September 2012
Verified
Conference Paper
Closed access
SVSrinivasan Venkatesh
Srinivasan Venkatesh
SGS. Mohamed Ghouse
S. Mohamed Ghouse
PRP. V. Ramamoorthi
P. V. Ramamoorthi
NSNatarajan Shanmugam
Natarajan Shanmugam
Electrical treeing is one of the significant causes for degradation of solid insulating materials, particularly in polymer and power cable insulation. It is an established fact that the extent of treeing in insulators is strongly related to the type of the dielectric material and the nature of flaw. In this research, detailed studies are carried out to investigate the electrical tree growth characteristics due to the effect of barrier in a composite polymeric insulation system, using a needle-plane electrode model. Laboratory studies have been conducted with a constant alternating voltage supply at power frequency (50 Hz) on composite virgin polymeric insulation specimen made up of two layers of Poly Methyl Meth Acrylate (PMMA) and an intermediate high permittivity layer of mica which acts as a barrier for tree growth. Electrical tree initiation and propagation is analyzed in relation to Partial Discharge (PD) signatures acquired from the PD measurement system and by correlating the physical aspects of degradation due to tree morphological structure. PD patterns during tree growth are analyzed in correlation with PD signatures with and without barrier. Phase resolved patterns of PD signatures obtained from the acquisition system are preprocessed and unique features are extracted based on statistical operators which in turn forms the input to the proposed Adaptive Probabilistic Neural Network (APNN) for discrimination of `tree' and `no-tree' patterns. For the purpose of comparison the original and adaptive versions of PNN have been taken up for detailed studies for discrimination of tree patterns. In addition, this study envisages ascertaining the role of the barrier in inhibiting the tree inception, nature of tree morphology and effect of space charge during tree propagation.

1 September 2012
Verified
Conference Paper
Closed access
NSNatarajan Shanmugam
Natarajan Shanmugam
RRRajesh Rajamani
Rajesh Rajamani
SVSrinivasan Venkatesh
Srinivasan Venkatesh
SGS. Mohamed Ghouse
S. Mohamed Ghouse
Assessment of the healthiness of insulation in transformers is a vital aspect for power system utilities since most in-service transformers which form the crux of the power system have reached its lifetime duration. Among many factors, moisture and ageing significantly influence the dielectric properties of a transformer. Recently, several researchers have proposed new diagnostic methods that are complementary to the classical measurement systems such as insulation resistance, power frequency dissipation factor, polarization index measurements etc. Dielectric diagnosis with polarization and depolarization currents (PDC) uses the dielectric system response in time domain. In this research a laboratory-built, compact and easy to construct PDC measurement system is implemented without compromising on the reliability of the measurement system. The capability of the measuring system is ascertained by carrying out detailed studies on scaled down laboratory models and a 315 kVA, 11kV/433V, Dyn 11, ONAN distribution transformer with artificially simulated insulation flaws namely moisture content in oil, inter-disc/ inter-turn shorts, winding asymmetry etc. Simulation studies on the transformer R-C equivalent representation are also carried out to validate the response of the PDC system. In addition, the Homoscedastic Probabilistic Neural Network (HOPNN) which utilized the Expectation Maximization (EM) with the Maximum Likelihood (ML) algorithm is implemented for obtaining a parsimonious training for subsequent identification of faults.