24 December 2020 in IEEE Access
Verified
Journal Article
Open access
SGSuganya Govindarajan
Suganya Govindarajan
JRJorge Alfredo Ardila Rey
Jorge Alfredo Ardila Rey
KKKannan Kirthivasan
Kannan Kirthivasan
JSJayalalitha Subbaiah
Jayalalitha Subbaiah
NSNikhith Sannidhi
Nikhith Sannidhi
MBM. Balasubramanian
M. Balasubramanian
Precise partial discharge (PD) detection is a key factor in anticipating insulation failures. The continuous efforts of researchers have led to the design of a variety of algorithms focusing on PD pattern classification. However, the trade-off between features taken up for classification and the detection rate continues to pose considerable challenges in terms of feature selection from acquired data, increased computing time, and so on. In this article, a Hypergraph (HG) based improved Random Forest (RF) algorithm by employing the Recursive Feature Elimination (RFE) algorithm (HG-RF-RFE), has been developed for PD source classification. HG representation of data is considered for obtaining statistical features, which turn out to be a subset of a set of all hyper edges called Hyper statistical features (Helly, Non-Helly, and Isolated hyper edges). HG-RF-RFE takes hyper statistical features and hyper edges as features for classification. The algorithm’s efficiency is tested against noise-free PD data obtained from SASTRA High Voltage Laboratory, and large-sized noisy PD data obtained from High-Voltage Research and Test Laboratory at Universidad Técnica Federico Santa Maria (LIDAT). The robustness of the proposed algorithm is tested with both time and phase domain PD features using the Mathews Correlation Coefficient (MCC), harmonic mean-based feature Score (F1 Score) as evaluation metrics, and by k-fold validation technique. The proposed HG-RF-RFE achieved 98.8% accuracy with minimal features and significantly reduces computation time without compromising accuracy. It is worth mentioning that the HG-RF-RFE technique is superior to many state of the art algorithms in terms of feature elimination and classification accuracy.

24 February 2020 in IEEE Access
Verified
Journal Article
Open access
NSNatarajan Shanmugam
Natarajan Shanmugam
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
RRRajesh Rajamani
Rajesh Rajamani
Frequency Response Analysis (FRA) is an Off-line condition monitoring technique for the transformers and is successful, in diagnosing mechanical faults and inter-turn short-circuits. Only limited literature is available for On-line FRA works, and the effect of the transformer’s load on the fault diagnosing capability of FRA has not yet been analysed. Motivated by this research gap, an experimental investigation was done to analyze the effect of load on IFRA based inter-turn short-circuit diagnosis. A single-phase 1 kVA, 240V/240 V transformer supplying R and R-L loads and a three-phase 5 kVA, 440 V/440 V transformer supplying an induction motor at various load levels were tested. Inter-turn short-circuits were emulated in their windings and, the effectiveness of IFRA in diagnosing the same was investigated. Comparisons were made between the frequency response of the loaded transformers in their healthier conditions and emulated fault conditions, based on the transfer function plots and the statistical parameters. Investigations reveal that the loads alter the useful spectrum of IFRA. The frequency response of the healthier transformer itself varies based on the transformer’s load and necessitates a careful focus on the sensitive frequency spectra for effective inter-turn short-circuit diagnosis in loaded transformers.

8 March 2021 in IEEE Access
Verified
Journal Article
Open access
NSNatarajan Shanmugam
Natarajan Shanmugam
SGSrinivasan Gopal
Srinivasan Gopal
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
SBS. P. Balaji
S. P. Balaji
RRRajesh Rajamani
Rajesh Rajamani
Inter-turn short circuits within the transformer winding are diagnosable through the impulse voltage based frequency response analysis (IFRA). If the diagnosis is made Online, interruption to the power network can be avoided. However, the transformer’s load may influence the frequency response based diagnostic process, and this aspect has not yet been investigated. Motivated by this research gap, experimental investigations were carried out on a three-phase 5 kVA, 440 V/440 V Star/Delta transformer and a three-phase 315 kVA, 11 kV/433 V, Dyn11 distribution transformer, when they were supplying power to loads of different magnitudes and power factors. The influence of the load current and its power factor on the IFRA was observed under the transformer’s healthy condition and with inter-turn short circuits in one of the windings. Investigations under these different loaded conditions revealed that a signature FRA plot developed at a particular load condition cannot be directly used for assessing the condition of the transformer at a different load. Both the magnitude and the power factor of the load are found to influence the frequency response. A careful interpretation of the Frequency response of the transformer, based on its load, was found effective in detecting and locating the inter-turn shorts.

17 December 2020 in IEEE Access
Verified
Journal Article
Open access
KAMALASELVAN ARUNACHALAMKAMALASELVAN ARUNACHALAM
KAMALASELVAN ARUNACHALAM
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
RRRajesh Rajamani
Rajesh Rajamani
Frequency response analysis (FRA) with low impulse voltage signals (IFRA) is useful in diagnosing faults like the mechanical displacements and inter-turn shorts in transformers. However, they fail to diagnose the presence of any source of partial discharges (PD) across the oil-paper insulation. PD is happening only above its inception voltage level for the applied signal, thereby changing the loading effect of the insulation system and becoming detectable. If FRA tests are extended carefully up to high voltages, they can be even useful for the preliminary diagnosis of the potential sources of PD. Investigations were not carried out so far to get an insight into this aspect. Motivated by this, an investigation was done, first time, on a 315 kVA, 11 kV/433 V transformer. IFRA was carried out carefully at various voltage levels, up to 50% of the Basic impulse insulation level. The IFRA results of the transformer under its healthier condition, under the emulated inter-turn shorts and, the PD sources across the major-insulation were, observed and compared. Low-voltage IFRA is found sufficient, only for diagnosing the inter-turn shorts. When IFRA is extended to moderately high voltage, it is found useful in the preliminary diagnosis of the PD sources.

24 March 2022 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
DSDevi Selvakumar
Devi Selvakumar
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan

22 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KAMALASELVAN ARUNACHALAMKAMALASELVAN ARUNACHALAM
KAMALASELVAN ARUNACHALAM
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
RRRajesh Rajamani
Rajesh Rajamani
Natarajan PrabaharanNatarajan Prabaharan
Natarajan Prabaharan
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
PSPierluigi Siano
Pierluigi Siano
The Frequency Response Analysis approach (FRA) is useful in the fault diagnosis of transformers. However, its usefulness in diagnosing any potential sources of Partial Discharge (PD) in transformers has not been thoroughly investigated so far. In this work, the use of Impulse voltage-based FRA (IFRA) in diagnosing inter-turn shorts and potential sources of PD were investigated on a 315 kVA, 11 kV/433 V transformer. Inter-turn shorts and PD sources were emulated and the usefulness of IFRA in their diagnosis was investigated while using switching impulse voltage at different magnitude levels as the test signals. For emulating the inter-turn shorts and the PDs, special tappings were provided on one of the 11 kV windings through the low capacitance bushings. Low voltage impulse was successful in diagnosing the inter-turn shorts, but unsuccessful in identifying the sources of PDs. During the test condition, the test voltage was adjusted with the presence of artificially created PD sources. The frequency response of the transformer before and after the inception of PD was observed and analyzed in this article. The FRA results demonstrated that the switching impulse voltage based IFRA approach at moderate voltages could be useful in diagnosing the presence of the potential sources of PDs.