18 October 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
RRRajesh Rajamani
Rajesh Rajamani
RMRajappa Muthaiah
Rajappa Muthaiah
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
Sweep frequency response analysis (SFRA) is a diagnostic technique which can identify faults within transformers. Though SFRA approaches are used to identify faults, their effectiveness in discriminating two same level faults at two different locations within transformer is not much analysed and reported. Experiments were carried out on a 1 kVA, single phase, 240 V/240 V laboratory transformers and on a 315 kVA, three phase, 11 kV/433 V, Dyn11, ONAN, distribution transformer, to analyse the usefulness of SFRA in inter turn short identification and discriminations. Faulty conditions were created artificially in transformers, by shorting the tappings provided in one of their windings, at different levels and locations. Open circuit self‐impedance and transfer voltage transfer function approaches were experimented and transfer function plots representing winding impedance and voltage transfer ratios at various frequencies were developed for transformers, under normal and faulty conditions. Significant differences were identified at some frequencies while comparing normal case plots with faulty case plots. It was observed that the SFRA is effective in identifying shorts within transformer winding as well as, discriminating two same level shorts (i.e.) locating shorts. Statistical analysis using absolute difference and min–max ratio also confirmed the efficacy of these approaches.

24 February 2020 in IEEE Access
Verified
Journal Article
Open access
NSNatarajan Shanmugam
Natarajan Shanmugam
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
RRRajesh Rajamani
Rajesh Rajamani
Frequency Response Analysis (FRA) is an Off-line condition monitoring technique for the transformers and is successful, in diagnosing mechanical faults and inter-turn short-circuits. Only limited literature is available for On-line FRA works, and the effect of the transformer’s load on the fault diagnosing capability of FRA has not yet been analysed. Motivated by this research gap, an experimental investigation was done to analyze the effect of load on IFRA based inter-turn short-circuit diagnosis. A single-phase 1 kVA, 240V/240 V transformer supplying R and R-L loads and a three-phase 5 kVA, 440 V/440 V transformer supplying an induction motor at various load levels were tested. Inter-turn short-circuits were emulated in their windings and, the effectiveness of IFRA in diagnosing the same was investigated. Comparisons were made between the frequency response of the loaded transformers in their healthier conditions and emulated fault conditions, based on the transfer function plots and the statistical parameters. Investigations reveal that the loads alter the useful spectrum of IFRA. The frequency response of the healthier transformer itself varies based on the transformer’s load and necessitates a careful focus on the sensitive frequency spectra for effective inter-turn short-circuit diagnosis in loaded transformers.

1 November 2017 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
RRRajesh Rajamani
Rajesh Rajamani
RMRajappa Muthaiah
Rajappa Muthaiah
KAMALASELVAN ARUNACHALAMKAMALASELVAN ARUNACHALAM
KAMALASELVAN ARUNACHALAM
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
Electrical shorts in transformers on load can be diagnosed by frequency response analysis (FRA) using impulse or sinusoidal sweep signal. At HV laboratory of SASTRA, a low‐voltage impulse based on‐line on‐load FRA (OLOL FRA) was carried out on a single phase 50 Hz, 1 kVA, 240 V/240 V small laboratory transformer while delivering power to lamp load, and the effectiveness in electrical short diagnosis was analysed. For this purpose, some artificial faults were created within one of the windings of the transformer investigated, and the responses of the winding to different frequency components of the impulse voltages were observed before and after introducing these faults. Comparison of the frequency response (impedance) of the winding under normal condition with frequency response under fault condition was made, which clearly indicated that faults had altered the winding impedance for some frequency components of the impulse. This reveals that fault within the winding can be identified and located, by the OLOL FRA technique, through careful comparisons of frequency response. Statistical analysis of transfer function magnitudes with correlation coefficient, standard deviation and absolute sum of logarithmic error has also validated the same.

8 March 2021 in IEEE Access
Verified
Journal Article
Open access
NSNatarajan Shanmugam
Natarajan Shanmugam
SGSrinivasan Gopal
Srinivasan Gopal
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
SBS. P. Balaji
S. P. Balaji
RRRajesh Rajamani
Rajesh Rajamani
Inter-turn short circuits within the transformer winding are diagnosable through the impulse voltage based frequency response analysis (IFRA). If the diagnosis is made Online, interruption to the power network can be avoided. However, the transformer’s load may influence the frequency response based diagnostic process, and this aspect has not yet been investigated. Motivated by this research gap, experimental investigations were carried out on a three-phase 5 kVA, 440 V/440 V Star/Delta transformer and a three-phase 315 kVA, 11 kV/433 V, Dyn11 distribution transformer, when they were supplying power to loads of different magnitudes and power factors. The influence of the load current and its power factor on the IFRA was observed under the transformer’s healthy condition and with inter-turn short circuits in one of the windings. Investigations under these different loaded conditions revealed that a signature FRA plot developed at a particular load condition cannot be directly used for assessing the condition of the transformer at a different load. Both the magnitude and the power factor of the load are found to influence the frequency response. A careful interpretation of the Frequency response of the transformer, based on its load, was found effective in detecting and locating the inter-turn shorts.

17 December 2020 in IEEE Access
Verified
Journal Article
Open access
KAMALASELVAN ARUNACHALAMKAMALASELVAN ARUNACHALAM
KAMALASELVAN ARUNACHALAM
BMBalasubramanian Madanmohan
Balasubramanian Madanmohan
RRRajesh Rajamani
Rajesh Rajamani
Frequency response analysis (FRA) with low impulse voltage signals (IFRA) is useful in diagnosing faults like the mechanical displacements and inter-turn shorts in transformers. However, they fail to diagnose the presence of any source of partial discharges (PD) across the oil-paper insulation. PD is happening only above its inception voltage level for the applied signal, thereby changing the loading effect of the insulation system and becoming detectable. If FRA tests are extended carefully up to high voltages, they can be even useful for the preliminary diagnosis of the potential sources of PD. Investigations were not carried out so far to get an insight into this aspect. Motivated by this, an investigation was done, first time, on a 315 kVA, 11 kV/433 V transformer. IFRA was carried out carefully at various voltage levels, up to 50% of the Basic impulse insulation level. The IFRA results of the transformer under its healthier condition, under the emulated inter-turn shorts and, the PD sources across the major-insulation were, observed and compared. Low-voltage IFRA is found sufficient, only for diagnosing the inter-turn shorts. When IFRA is extended to moderately high voltage, it is found useful in the preliminary diagnosis of the PD sources.

1 June 2006
Verified
Conference Paper
Closed access
BKB. Karthikeyan
B. Karthikeyan
RRRajesh Rajamani
Rajesh Rajamani
MBM. Balasubramanian
M. Balasubramanian
SSS. Saravanan
S. Saravanan
The objective of lightning impulse voltage (LI Voltage) test on power transformer is to check the dielectric strength of the transformer against over voltages of atmospheric origin. Mostly when transformers of high transformation ratio is subjected to LI voltage test, the standard LI voltage waveshape distorts and consequently the wavetail falls much below the specified tolerance and swings to opposite polarity. In these cases, IEC has suggested some waveshape improvement techniques in the test circuit or energy enhancement of the impulse generator. This paper elucidates the experimental investigations carried out on a 315 kVA, 11 kV/433 V, Dyn 11, three phase transformer. Investigations was carried out based on the voltage and stress analysis on the transformer windings. For this analysis, tapping are provided on one of the HV winding at 100%, 87.5%, 62.5%, 37.5%, and 12.5%. The investigations include voltage and stress distribution on the windings, voltage across the waveshape component and analysis of stress across major and minor insulation. Apart from voltage and stress distribution analysis, a few novel techniques of waveshape improvement are attempted and a comparative analysis with IEC methods is also presented in this paper