Alessandra Tuzita

Ms. Alessandra Tuzita

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
HNHenrique Tuzzolo Neto
Henrique Tuzzolo Neto
ATAlessandra Tuzita
Alessandra Tuzita
Sergio GehrkeSergio Gehrke
Sergio Gehrke
RMRenata de Vasconcellos Moura
Renata de Vasconcellos Moura
MCMarcio Z. Casati
Marcio Z. Casati
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
This study aimed at performing a comparative analysis of the fracture resistance of implants, evaluating extra-narrow, narrow, and regular implants. Four groups containing 15 implants each were evaluated. Group 1 (G1): single-piece extra-narrow implants; Group 2 (G2): single-piece narrow implants; Group 3 (G3): Morse taper narrow implants with solid abutments; Group 4 (G4): Morse taper conventional implants with solid abutments. The implants were tested using a universal testing machine for their maximum force limit and their maximum bending moment. After obtaining the data, the Shapiro–Wilk, ANOVA, and Tukey (p < 0.05) statistical tests were applied. Samples from all the groups were analyzed by scanning electron microscopy and Groups 3 and 4 were analyzed by profilometry. The means and the standard deviation values for the maximum force limit (N) and the maximum bending moment (Nmm) were respectively: G1:134.29 N (10.27); G2:300.61 N (24.26); G3:360.64 N (23.34); G4:419.10 N (18.87); G1:1612.02 Nmm (100.6); G2:2945 Nmm (237.97); G3:3530.38 Nmm (228.75); G4:4096.7 Nmm (182.73). The groups behaved statistically different from each other, showing that the smallest diameter implants provided less fracture resistance, both in the tensile strength tests and in the maximum bending moment between all groups. Furthermore, single-piece implants, with 2.5 mm and 3.0 mm diameters, deformed in the implant body region area, rather than in the abutment region.

12 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ABAna Paula Granja Scarabel Nogueira Bella
Ana Paula Granja Scarabel Nogueira Bella
ATAlessandra Tuzita
Alessandra Tuzita
ISIvana Barbosa Suffredini
Ivana Barbosa Suffredini
AKAlberto Noriyuki Kojima
Alberto Noriyuki Kojima
EGElcio Magdalena Giovani
Elcio Magdalena Giovani
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
This study evaluated the bacterial infiltration and the detorque of indexed and non-indexed abutments of Morse taper implants (MTI) after mechanical cycling (MC). 40 MTI were distributed into four groups: IIA (indexed implant abutments); NIIA (non-indexed implant abutments); IIAMC (indexed implant abutments submitted to MC); NIIAMC (non-indexed implant abutments submitted to MC), which were carried out under one million 5 Hz frequency and 3 Bar pressure. After mechanical cycling, all groups were immersed in a bacterial solution in Brain Heart Infusion Agar. After detorque, the bacteria infiltration was evaluated by counting the colony-forming units. For the bacterial infiltration, analysis was applied to the Kruskal–Wallis test (p = 0.0176) followed by Dunn’s test. For the detorque analysis, the two-way repeated-measures ANOVA was applied, followed by the Tukey’s test (p < 0.0001). Bacteria infiltration was highly observed in NIIA (p = 0.0027) and were absent in IIAMC and NIIAMC. The detorque values for IIA (19.96Ncm ± 0.19Ncm), NIIA (19.90Ncm ± 0.83Ncm), and NIIAMC (19.51Ncm ± 0,69Ncm) were similar and remained close to the initial value, while IIAMC (55.2Ncm ± 2.36Ncm) showed an extremely significant torque value increase (p < 0.0001). The mechanical cycling resulted in mechanical sealing of the implant-abutment interface, preventing bacterial infiltration in the indexed and non-indexed specimens, and increasing the detorque strength in the group of indexed abutments.

22 March 2022 in Research Square
Verified
Preprint
Open access
PDF file
ATAlessandra Tuzita
Alessandra Tuzita
ABAna Paula Granja Scarabel Nogueira Bella
Ana Paula Granja Scarabel Nogueira Bella
ISIvana Barbosa Suffredini
Ivana Barbosa Suffredini
AKAlberto Noriyuki Kojima
Alberto Noriyuki Kojima
EGElcio Magdalena Giovani
Elcio Magdalena Giovani
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
This study evaluated the bacterial infiltration and the detorque of indexed and non-indexed abutments of Morse taper implants (MTI) after mechanical cycling (MC). 40 MTI were distributed into four groups: IIA-indexed implant abutments; NIIA-non-indexed implant abutments; IIAMC-indexed implant abutments submitted to MC; NIIAMC-non-indexed implant abutments submitted to MC, which were carried out under one million 5Hz frequency and 3 Bar pressure. After mechanical cycling, all groups were immersed in a bacterial solution in Brain Heart Infusion Agar. After detorque, the bacteria infiltration was evaluated by counting the colony-forming units. For the bacterial infiltration analysis were applied the Kruskal-Wallis test (p = 0.0176) followed by Dunn’s test. For the detorque analysis, the two-way repeated measures ANOVA was applied, followed by the Tukey’s test (p < 0.0001). Bacteria infiltration was highly observed in NIIA (p = 0.0027),and was absent in IIAMC and NIIAMC. The detorque values for IIA (19.96Ncm ± 0.19Ncm), NIIA (19.90Ncm ± 0.83Ncm), and NIIAMC (19.51Ncm ± 0,69Ncm) were similar and remained close to the initial value, while IIAMC (55.2Ncm ± 2.36Ncm) showed an extremely significant torque value increase (p < 0.0001). The mechanical cycling resulted in mechanical sealing of the implant-abutment interface, preventing bacterial infiltration in the indexed and non-indexed specimens, and increasing the detorque strength in the group of indexed abutments.