Alfredo Mikail Melo Mesquita

Dr. Alfredo Mikail Melo Mesquita

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2023 in Medicina
Verified
Journal Article
Open access
PDF file
Sergio GehrkeSergio Gehrke
Sergio Gehrke
GCGuillermo Castro Cortellari
Guillermo Castro Cortellari
Gustavo FernandesGustavo Fernandes
Gustavo Fernandes
Antonio ScaranoAntonio Scarano
Antonio Scarano
RMRafael Garcia Martins
Rafael Garcia Martins
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 ± 6.41 Ncm for the DC group and 29.3 ± 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 ± 3.78 and 69.8 ± 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 ± 3.92 and 72.1 ± 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.

Verified
Journal Article
Open access
PDF file
Sergio GehrkeSergio Gehrke
Sergio Gehrke
Antonio ScaranoAntonio Scarano
Antonio Scarano
GCGuillermo Castro Cortellari
Guillermo Castro Cortellari
Gustavo FernandesGustavo Fernandes
Gustavo Fernandes
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
MBMarco Bianchini
Marco Bianchini
The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-taper connection implants (DuoCone implant) with two-piece straight abutment baseT used for at least 12 months, presenting periapical radiograph immediately after crown installation were enrolled. The position of the rehabilitated tooth and arch (maxilla or mandible), crown installation period, implant dimensions, abutment transmucosal height, installation site (immediate implant placement or healed area), associated with bone regeneration, immediate provisionalization, and complications after installation of the final crown were analyzed. The initial and final MBL was evaluated by comparing the initial and final X-rays. The level of significance was α = 0.05. Seventy-five patients (49 women and 26 men) enrolled had a mean period of evaluation of 22.7 ± 6.2 months. Thirty-one implant-abutment (IA) sets had between 12–18 months, 34 between 19–24 months, and 44 between 25–33 months. Only one patient failed due to an abutment fracture after 25 months of function. Fifty-eight implants were placed in the maxilla (53.2%) and 51 in the mandible (46.8%). Seventy-four implants were installed in healed sites (67.9%), and 35 were in fresh socket sites (32.1%). Thirty-two out of these 35 implants placed in fresh sockets had the gap filled with bone graft particles. Twenty-six implants received immediate provisionalization. The average MBL was −0.67 ± 0.65 mm in mesial and −0.70 ± 0.63 mm in distal (p = 0.5072). The most important finding was the statistically significant difference comparing the values obtained for MBL between the abutments with different transmucosal height portions, which were better for abutments with heights greater than 2.5 mm. Regarding the abutments’ diameter, 58 had 3.5 mm (53.2%) and 51 had 4.5 mm (46.8%). There was no statistical difference between them, with the following means and standard deviation, respectively, −0.57 ± 0.53 mm (mesial) and −0.66 ± 0.50 mm (distal), and −0.78 ± 0.75 mm (mesial) and −0.746 ± 0.76 mm (distal). Regarding the implant dimensions, 24 implants were 3.5 mm (22%), and 85 implants (78%) had 4.0 mm. In length, 51 implants had 9 mm (46.8%), 25 had 11 mm (22.9%), and 33 implants were 13 mm (30.3%). There was no statistical difference between the abutment diameters (p > 0.05). Within the limitations of this study, it was possible to conclude that better behavior and lesser marginal bone loss were observed when using abutment heights greater than 2.5 mm of transmucosal portion and when placed implants with 13 mm length. Furthermore, this type of abutment showed a little incidence of failures within the period analyzed in our study.

17 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
HNHenrique Tuzzolo Neto
Henrique Tuzzolo Neto
ATAlessandra Tuzita
Alessandra Tuzita
Sergio GehrkeSergio Gehrke
Sergio Gehrke
RMRenata de Vasconcellos Moura
Renata de Vasconcellos Moura
MCMarcio Z. Casati
Marcio Z. Casati
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
This study aimed at performing a comparative analysis of the fracture resistance of implants, evaluating extra-narrow, narrow, and regular implants. Four groups containing 15 implants each were evaluated. Group 1 (G1): single-piece extra-narrow implants; Group 2 (G2): single-piece narrow implants; Group 3 (G3): Morse taper narrow implants with solid abutments; Group 4 (G4): Morse taper conventional implants with solid abutments. The implants were tested using a universal testing machine for their maximum force limit and their maximum bending moment. After obtaining the data, the Shapiro–Wilk, ANOVA, and Tukey (p < 0.05) statistical tests were applied. Samples from all the groups were analyzed by scanning electron microscopy and Groups 3 and 4 were analyzed by profilometry. The means and the standard deviation values for the maximum force limit (N) and the maximum bending moment (Nmm) were respectively: G1:134.29 N (10.27); G2:300.61 N (24.26); G3:360.64 N (23.34); G4:419.10 N (18.87); G1:1612.02 Nmm (100.6); G2:2945 Nmm (237.97); G3:3530.38 Nmm (228.75); G4:4096.7 Nmm (182.73). The groups behaved statistically different from each other, showing that the smallest diameter implants provided less fracture resistance, both in the tensile strength tests and in the maximum bending moment between all groups. Furthermore, single-piece implants, with 2.5 mm and 3.0 mm diameters, deformed in the implant body region area, rather than in the abutment region.

1 December 2019 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
DCDebora Elias Calabro
Debora Elias Calabro
AKAlberto N Kojima
Alberto N Kojima
VPVanessa Gallego Arias Pecorari
Vanessa Gallego Arias Pecorari
CSCíntia Helena Coury Saraceni
Cíntia Helena Coury Saraceni
BBBlatz Markus Bernhard
Blatz Markus Bernhard
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
Purpose: To evaluate the survival rate in restored teeth with three different types of retainers prior to the fixing of crowns with zirconia through this retrospective clinical study. It is unclear how the type of post and core rehabilitation, and type of resin cement affect the longevity of teeth restored with crowns. Methods: In a private clinic, a total of 101 retainers installed by the same professional between June 2008 and January 2018, with an average time of 58.2 months (4.8 years), were analyzed regarding the following factors: survival, cement and failure type. Three types of retainers were used according to the indications found in the literature: filling with Z250 light-cured composite resin, 22 elements; fiberglass post with Z250 light-cured composite resin, 45 elements; and cast metallic core in silver-tin alloy, 34 elements. The retainers were cemented with chemically cured cement, U100, U200, or Panavia F. Results: Data were subjected to Kaplan-Meier analysis (p=0.495). Although the study presented several limitations, no significant differences were observed in the success rates between the types of intra-radicular retainers and the type of cement. The success rates were as follows: metal core, 97.1%; fiberglass post, 95.6%; and filling, 100%. On average, failures occurred at 48.4 months. Conclusion: In view of the results, it is possible to conclude that the different retainers evaluated have similar survival rates.

6 December 2018 in Case Reports in Dentistry
Verified
Journal Article
Open access
PDF file
HNHenrique Tuzzolo Neto
Henrique Tuzzolo Neto
WNWagner Ferreira Do Nascimento
Wagner Ferreira Do Nascimento
LELarissa Erly
Larissa Erly
RRRodrigo Alves Ribeiro
Rodrigo Alves Ribeiro
JBJorge de Sá Barbosa
Jorge de Sá Barbosa
CCClaudio Costa
Claudio Costa
Currently, there has been a growing demand for restorations of anterior teeth in the routine of doctors in dental offices. With advances in adhesive technology and good properties of the available ceramics, the use of ceramic veneers has been offered as a treatment option for cases where teeth have minor color changes and shape and position changes. Through careful treatment planning, it is possible to conservatively use ceramic veneers in the treatments, applying techniques with minimal wear of the teeth and obtaining excellent aesthetic results with mechanical stability and biocompatibility with the periodontal tissues and clinical longevity. This clinical case report was used to design the digital smile, which guided the production of the diagnostic waxing of the superior model. Silicone guides were then made to create the mock-up, orienting enamel/dentin wear and assisting the preparation of the crowns with bis-acryl resin. When the wear was finished, the gingival separation was performed using the double-thread technique. In the molding process, the second wire was withdrawn and the molding material flowed into the gingival groove, copying the terminal region. After analysis of the quality of the impression, the temporary crowns were made with bis-acryl resin, using the guide. The color of the cementing agent was chosen using a glycerin-based compound which simulates the final color of the cement. After two hours of drying, two different layers of silane were applied for 60 seconds. After the preparation of the piece, gingival isolation and separation were done. The dental substrate was degreased with detergent solution and conditioned with 37% phosphoric acid for 15 seconds and then washed for 45 seconds for subsequent drying, leaving the substrate moistened. The adhesive system was applied for 30 seconds, waiting for the adhesive to penetrate into the conditioned dentinal tubules. A light air jet was applied, and then each tooth was photopolymerized for 30 seconds. The resin cement was placed inside the pieces and placed in position and photopolymerized. The excess cement was removed; after a layer of glycerin in the cervical region, aiming to block the entry of oxygen and polishing was performed. The purpose of this case report was to describe a sequence of clinical steps, from planning to cementation, in a case of aesthetic correction using feldspathic ceramic veneers.

1 June 2007 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
AJAna Paula Gumieiro Jaime
Ana Paula Gumieiro Jaime
DVDiego Klee de Vasconcellos
Diego Klee de Vasconcellos
AMAlfredo Mikail Melo Mesquita
Alfredo Mikail Melo Mesquita
EKEstevão Tomomitsu Kimpara
Estevão Tomomitsu Kimpara
Marco BottinoMarco Bottino
Marco Bottino
This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. Two groups were analyzed: test group – 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group – 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (α= 5%). The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68μm to 14.83μm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18μm) similar to those of premachined components (14.3 μm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 μm to 14.6 μm; p<0.05). There were no significant changes after porcelain baking, in both groups. The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.