Jan Bauer

Dr. Jan Bauer

Department of Electric Drives and Traction, Czech Technical University in Prague, 166 27 Prague, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2021 in IEEE Transactions on Vehicular Technology
Verified
Journal Article
Closed access
PPPetr Pichlik
Petr Pichlik
Jan BauerJan Bauer
Jan Bauer
Slip controllers are crucial for railway vehicle operation when a high tractive effort is required. The slip controllers have been developed for decades, and their developments continue. The developed slip controllers are based on many more or less effective principles. One of the perspective slip controllers determines a phase shift between an injected excitation signal to the required torque of the electric drive and the signal representation in a measured wheel angular velocity. The slip controllers that are based on the principle can effectively work with any adhesion conditions. However, the slip controller principle has some drawbacks like high filtration requirements, possible failure due to mechanical shock in the wheel-rail contact and long response time. The paper proposes a novel phase shift detection method for the slip controller based on an unscented Kalman filter that can cope with the known disadvantages of the original slip controller. When the proper output of the UKF is used, the slip controller becomes faster, more reliable and can work when the original slip controller fails. The proposed slip controller was verified on the measured data in an open-loop calculation and the mathematical model in the closed-loop simulation.

14 December 2021 in IEEE Access
Verified
Journal Article
Open access
OLOndrej Lipcak
Ondrej Lipcak
Jan BauerJan Bauer
Jan Bauer
Although still widely used due to its robustness, reliability, and low cost, induction motor (IM) has a disadvantage of more complicated mathematical description than permanent magnet AC machines. In high-demanding applications, the decoupled control of the machine’s flux and torque along with the proper function of selected efficiency-improving and flux-weakening algorithms can be achieved only if the IM parameters are known with sufficient accuracy. For parameter estimation, many algorithms have been proposed in the literature so far. Due to its simple and straightforward implementation, one of the popular estimation strategies is the model reference adaptive system (MRAS). However, MRAS-based algorithms for a specific parameter estimation tend to be sensitive to other machine parameters. For instance, most of the proposed MRAS algorithms do not consider the influence of the phenomena such as iron losses and load-dependent saturation. Since one of the most performance-decisive parameters of the popular rotor flux-oriented control (RFOC) are the magnetizing inductance and the rotor resistance, this paper aims to present a novel MRAS-based magnetizing inductance estimator (Lm-MRAS) with the included effect of iron losses. Furthermore, to enable the identification of the load-dependent saturation, another MRAS with included iron losses based on reactive power is proposed to work parallelly with Lm-MRAS, since under load conditions, the rotor resistance mismatch causes RFOC detuning. The adaptation law of the Lm-MRAS is obtained using the Lyapunov function approach and further examined using small-signal analysis. The proposed algorithms are verified on a 3.6 kW IM drive both in simulations and experiments.

13 February 2020 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
PPPetr Pichlik
Petr Pichlik
Jan BauerJan Bauer
Jan Bauer
Locomotives are equipped with slip controllers that improve their adhesion utilization and keep wheels slip velocities at appropriate values. The current slip controllers typically correctly work during the regular train run. However, there are some cases when some slip controllers may fail. The correct operation at low velocities is one of the cases in which the slip controller can fail. The long-time response of the velocity measurement that is caused by incremental encoders with a low number of pulses per revolution is causing the problem in this case. The wheel slippage can occur when the adhesion conditions are adverse, and applied forces are high in this case. This paper describes a novel slip controller based on the unscented Kalman filter that correctly works during the train low velocity operation with any adhesion conditions. The slip controller was designed with taking into account all aspects that influence the controller operation. Therefore, the adhesion, electric drive, the slip controller, and problem background are described in the paper. The slip controller functionality is verified on measured data and a mathematical model that was verified on the measured data.

28 March 2020 in Electronics
Verified
Journal Article
Open access
PDF file
PKPavel Karlovský
Pavel Karlovský
OLOndrej Lipcak
Ondrej Lipcak
Jan BauerJan Bauer
Jan Bauer
Today’s modern control strategies of an induction motor (IM) drive require a power source with an adjustable output voltage frequency and amplitude. The most commonly used converter topology is a two-level voltage-source inverter (VSI). However, the utilization of a VSI introduces additional voltage and current distortion, which leads to additional power losses in the machine’s magnetic circuit. Both the transistor switching frequency and the type of the inverter control determine the total harmonic distortion (THD) of the motor’s phase currents. In this paper, the influence of the inverter DC-link voltage on the iron losses of an IM controlled by a predictive torque control (PTC) is presented. It is shown that if the IM drive operates below the rated speed, it is possible to modify the PTC algorithm to reduce the additional iron losses caused by the non-harmonic inverter output voltage. The control of the DC-link voltage is achieved by using a silicon-controlled rectifier. Experiments were conducted on a 5.5 kW IM controlled by PTC, and the results are compared against a sinusoidal voltage supply created by a synchronous generator.

20 January 2012 in Automatika
Verified
Journal Article
Open access
Jan BauerJan Bauer
Jan Bauer
SFStanislav Flígl
Stanislav Flígl
ASAndreas Steimel
Andreas Steimel
Design and Dimensioning of Essential Passive Components for the Matrix Converter Prototype

24 March 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
JKJakub Kučera
Jakub Kučera
OLOndrej Lipcak
Ondrej Lipcak
Jan BauerJan Bauer
Jan Bauer
The dual-inverter (DI) with galvanically isolated dc supplies offers advantages such as multilevel and fault-tolerant operation, superior dc voltage utilization, and simple control, making it particularly attractive for traction applications. The DI provides significant flexibility in output voltage synthesis by utilizing two conventional voltage-source inverters (VSIs) to supply each end of the load. This article leverages that flexibility by proposing several modulation strategies, where one inverter operates in a six-step (square-wave) mode, and the other utilizes a modified space vector pulse width modulation (SVPWM) or discontinuous pulse width modulation (DPWM). These strategies efficiently reduce switching losses while maintaining low implementation complexity through the reference signal deformation approach. The proposed modulations are theoretically analyzed for switching loss reduction and experimentally validated on an induction machine under closed-loop field-oriented control to confirm their effectiveness compared to conventional approaches.