The dual-inverter (DI) with galvanically isolated dc supplies offers advantages such as multilevel and fault-tolerant operation, superior dc voltage utilization, and simple control, making it particularly attractive for traction applications. The DI provides significant flexibility in output voltage synthesis by utilizing two conventional voltage-source inverters (VSIs) to supply each end of the load. This article leverages that flexibility by proposing several modulation strategies, where one inverter operates in a six-step (square-wave) mode, and the other utilizes a modified space vector pulse width modulation (SVPWM) or discontinuous pulse width modulation (DPWM). These strategies efficiently reduce switching losses while maintaining low implementation complexity through the reference signal deformation approach. The proposed modulations are theoretically analyzed for switching loss reduction and experimentally validated on an induction machine under closed-loop field-oriented control to confirm their effectiveness compared to conventional approaches.
17 September 2015 in International Journal of Microwave Science and Technology
The cross-correlation method allows phase-noise measurements of high-quality devices with very low noise levels, using reference sources with higher noise levels than the device under test. To implement this method, a phase-noise analyzer needs to compute the cross-spectral density, that is, the Fourier transform of the cross-correlation, of two time series over a wide frequency range, from fractions of Hz to tens of MHz. Furthermore, the analyzer requires a high dynamic range to accommodate the phase noise of high-quality oscillators that may fall off by more than 100 dB from close-in noise to the noise floor at large frequency offsets. This paper describes the efficient implementation of a cross-spectrum analyzer in a low-cost FPGA, as part of a modern phase-noise analyzer with very fast measurement time.
The increasing popularity of electric drives employing an isolated dual-inverter (DI) topology is motivated by their superior DC-link voltage and power utilization, fault-tolerant operation, and potential for multilevel operation. These attributes are significant in battery-powered transportation, such as electric vehicles and aviation. Given the considerable freedom in modulation and control of the DI topology, this paper researches the impact of reference voltage vector distribution between the two individual inverters. The study also evaluates the influence of two well-established asynchronous modulation strategies—Space Vector PWM (SVPWM) and Depenbrock’s Discontinuous Modulation (DPWM1). Since simulation tools nowadays play a crucial role in power electronics design and concept verification, the results are based on extensive and detailed models in Matlab/Simulink. Employing the basic field-oriented control of a 12 kW induction motor with precisely parameterized SiC switching devices for accurate loss calculation, this research reveals the possibility of significant energy savings at multiple operating points. Notably, optimal efficiency is achieved when one inverter operates up to half of the nominal speed while the other solely establishes a neutral point for the winding. Moreover, the results highlight DPWM1 as a superior strategy for the DI topology, showcasing reduced converter losses. Overall, it is shown that the system’s losses can be significantly reduced just by the design of the voltage vector distribution in the drive’s operating range and the modulation strategy selection.
22 January 2025 in IEEE Transactions on Power Electronics
Discontinuous PWM (DPWM) strategies are widely used in Voltage-Source Inverters (VSIs) due to reduced switching losses and improved harmonic performance at higher modulation indexes. However, DPWMs with discontinuous Zero-Sequence Signals (ZSS) can cause current spikes at clamping instants, which depend on the modulation index and load parameters. In the literature, this behavior is often attributed to the rapid changes in ZSS. This paper demonstrates that the current spikes are primarily caused by improper modulator implementation on Digital Signal Processors (DSPs), which introduces an unintended active vector instead of a zero vector at the end of a positive bus clamp for a given phase. The issue arises because PWM modules operate as set-reset units based on a timer and compare values, unlike analog comparators, which react instantaneously. We propose a simple solution using an auxiliary compare register, which is effective for most DSPs. The solution's effectiveness is demonstrated on a VSI-fed 12-kW induction machine controlled by a C2000 Texas Instruments DSP.
1 January 2026 in IEEE Transactions on Transportation Electrification