The advantages of planar Hall effect (PHE) sensors—their thermal stability, very low detection limits, and high sensitivities—have supported a wide range of advanced applications such as nano-Tesla (nT) magnetometers, current sensing, or low magnetic moment detection in lab-on-a-chip devices. In this review we outline the background and implications of these PHE sensors, starting from fundamental physics through their technological evolution over the past few decades. Key parameters affecting the performance of these sensors, including noise from different sources, thermal stability, and magnetoresistance magnitudes are discussed. The progression of sensor geometries and junctions from disk, cross-to-bridge, ring, and ellipse configuration is also reviewed. The logical sequence of these structures from single magnetoresistive layers to bi-, tri-layers, and spin-valves is also covered. Research contributions to the development of these sensors are highlighted with a focus on microfluidics and flexible sensorics. This review serves as a comprehensive resource for scientists who wish to use PHE for fundamental research or to develop new applications and devices. The conclusions from this report will benefit the development, production, and performance evaluation of PHE-based devices and microfluidics, as well as set the stage for future advances.
This paper presents the design and implementation of a high sensitivity giant magnetoresistance (GMR) based current sensor with a broad range of applications. The novelty of our approach consists in using a double differential measurement system, based on commercial GMR sensors, with an adjustable biasing system used to linearize the field response of the system. The work aims to act as a fully-operational proof of concept application, with an emphasis on the mode of operation and methods to improve the sensitivity and linearity of the measurement system. The implemented system has a broad current measurement range from as low as 75 mA in DC and 150 mA in AC up to 4 A by using a single setup. The sensor system is also very low power, consuming only 6.4 mW. Due to the way the sensors are polarized and positioned above the U-shaped conductive band through which the current to be measured is flowing, the differential setup offers a sensitivity of about between 0.0272 to 0.0307 V/A (signal from sensors with no amplifications), a high immunity to external magnetic fields, low hysteresis effects of 40 mA, and a temperature drift of the offset of about −2.59×10−4 A/°C. The system provides a high flexibility in designing applications where local fields with very low amplitudes must be detected. This setup can be redesigned for a wide range of applications, thus allowing further specific optimizations, which would provide an even greater accuracy and a significantly extended operation range.
Many applications require galvanic isolation between the circuit where the current is flowing and the measurement device. While for AC, the current transformer is the method of choice, in DC and, especially for low currents, other sensing methods must be used. This paper aims to provide a practical method of improving the sensitivity and linearity of a giant magnetoresistance (GMR)-based current sensor by adapting a set of design rules and methods easy to be implemented. Our approach utilizes a multi-trace current trace and a double differential GMR based detection system. This essentially constitutes a planar coil which would effectively increase the usable magnetic field detected by the GMR sensor. An analytical model is developed for calculating the magnetic field generated by the current in the GMR sensing area which showed a significant increase in sensitivity up to 13 times compared with a single biased sensor. The experimental setup can measure both DC and AC currents between 2–300 mA, with a sensitivity between 15.62 to 23.19 mV/mA, for biasing fields between 4 to 8 Oe with a detection limit of 100 μA in DC and 100 to 300 μA in AC from 10 Hz to 50 kHz. Because of the double differential setup, the detection system has a high immunity to external magnetic fields and a temperature drift of the offset of about −2.59 × 10−4 A/°C. Finally, this setup was adapted for detection of magnetic nanoparticles (MNPs) which can be used to label biomolecules in lab-on-a-chip applications and preliminary results are reported.
() and() thin films were synthesized by sol-gel method. The structure and the surface morphology of zinc oxide thin films doped with transition metal (TM) ions have been investigated by X-ray diffraction (XRD) and atomic force microscopy (AFM). The magnetic studies were done using vibrating sample magnetometer (VSM) at room temperature. Experimental results revealed that the substitution of Ni ions in ZnO wurtzite lattice for the contents() leads to weak ferromagnetism of thin films. Forwith, theions are magnetic coupling by superexchange interaction via oxygen ions in wurtzite structure. For() one can observe the increasing of secondary phase of ZnFe2O4spinel. The Zn0.9Fe0.1O film shows a superparamagnetic behavior due to small crystallite sizes and the net spin magnetic moments arisen from the interaction between the iron ions through an oxygen ion in the spinel structure.
Non-contact, highly accurate and fully automated measurement of the blood plasma viscosity using the optical transparency technique at a constant temperature of 37 °C.
1 May 2015 in Journal of Magnetism and Magnetic Materials