Hui Li

Mrs. Hui Li

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HLHui Li
Hui Li
CCCheng Chen
Cheng Chen
TWTongguang Wang
Tongguang Wang
LWLong Wang
Long Wang
The objective of this paper was to design configuration parameters for a stepped-lap scarf joint repair, which can be used for spar cap damage of a wind turbine blade in service and to realize the post-repair monitoring. Two experimental studies were included. First, tensile test for the unidirectional tape specimens with a large aspect ratio repaired using a multiple stepped-lap scarf joint method was carried out. The results showed that the reinforcement layer could effectively improve the load-carrying capacity of the repaired zone. The stepped-lap joint surface was identified as the weak part of the spar cap repair, which should be monitored. Second, by embedding carbon nanotube buckypaper sensors on the stepped-lap joint surface of the repaired specimens, quasi-static tensile tests and fatigue tests were carried out. According to the resistance response of the sensors, the quasi-static tensile test confirmed the failure processes, namely the stiffness turning point, damage evolution, crack propagation, and fracture. The fatigue test could accurately identify the progressive failure, namely the initial damage, damage accumulation, initial cracking, and crack propagation to structural failure. The above tests provided an important configuration parameter basis for evaluating the spar cap repair scheme and presented a promising method for the health monitoring of a spar cap after repair.

15 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CCCheng Chen
Cheng Chen
HLHui Li
Hui Li
TWTongguang Wang
Tongguang Wang
LWLong Wang
Long Wang
Wind turbines are under continuous development for large-scale deployment and oceanization, leading to the requirement of longer blades. The economic losses caused by blade replacement and shutdown have increased. The downtime caused by blade issues in a wind turbine is 8–20% of the total downtime. Many of these blade issues originate from the cracking of the blade trailing edge. The edge is more susceptible to damage due to the complex geometry, manufacturing technique, and operation conditions. The traditional design method and the expensive experimental research are not suitable for the accurate damage analysis of the trailing-edge adhesive because of simplifying assumptions and costs. This study aimed to investigate the influence of trailing-edge structural configurations on the shear fatigue life of the trailing-edge adhesive joint using finite element and stress transformation matrix (STM) methods. The structural configurations of the blade trailing edge included the position of unidirectional fiber layer (UD), chamfer of bonding line, prefabricated components, and outer over-lamination of the trailing edge. In this study, the finite element method was used to simulate the blade structure. The shell element was used for laminates, and the solid element was used for the trailing-edge adhesive joint. The basic shear fatigue properties of the adhesive were obtained by standard component tests. The shear fatigue life of the blade trailing-edge adhesive joint under given load conditions was calculated using the fatigue properties of the adhesive and STM method. The results showed that the angle of chamfering, location of UD, rigidity of the preform, and outer over-lamination all had an obvious influence on the fatigue damage of trailing-edge adhesive. The findings of this study can be used to guide blade structure design and blade production and maintenance.

4 June 2018 in E3S Web of Conferences
Verified
Conference Paper
Open access
YBYu Bei Bei
Yu Bei Bei
HLHui Li
Hui Li
LLLi Dong Lin
Li Dong Lin
This Gs64 gas reservoir is a condensate gas reservoir which is relatively integrated with low porosity and low permeability found in Dagang Oilfield in recent years. The condensate content is as high as 610g/m3. At present, there are few reports about the well spacing of similar gas reservoirs at home and abroad. Therefore, determining the reasonable well spacing of the gas reservoir is important for ensuring the optimal development effect and economic benefit of the gas field development. This paper discusses the reasonable well spacing of the deep and low permeability gas reservoir from the aspects of percolation mechanics, gas reservoir engineering and numerical simulation. considering there exist the start-up pressure gradient in percolation process of low permeability gas reservoir, this paper combined with productivity equation under starting pressure gradient, established the formula of gas well spacing with the formation pressure and start-up pressure gradient. The calculation formula of starting pressure gradient and well spacing of gas wells. Adopting various methods to calculate values of gas reservoir spacing are close to well testing' radius, so the calculation method is reliable, which is very important for the determination of reasonable well spacing in low permeability gas reservoirs.