The objective of this paper was to design configuration parameters for a stepped-lap scarf joint repair, which can be used for spar cap damage of a wind turbine blade in service and to realize the post-repair monitoring. Two experimental studies were included. First, tensile test for the unidirectional tape specimens with a large aspect ratio repaired using a multiple stepped-lap scarf joint method was carried out. The results showed that the reinforcement layer could effectively improve the load-carrying capacity of the repaired zone. The stepped-lap joint surface was identified as the weak part of the spar cap repair, which should be monitored. Second, by embedding carbon nanotube buckypaper sensors on the stepped-lap joint surface of the repaired specimens, quasi-static tensile tests and fatigue tests were carried out. According to the resistance response of the sensors, the quasi-static tensile test confirmed the failure processes, namely the stiffness turning point, damage evolution, crack propagation, and fracture. The fatigue test could accurately identify the progressive failure, namely the initial damage, damage accumulation, initial cracking, and crack propagation to structural failure. The above tests provided an important configuration parameter basis for evaluating the spar cap repair scheme and presented a promising method for the health monitoring of a spar cap after repair.
The traditional power collection system design separately optimizes the connection topology and the cable cross sections, which may result in the inherent shortcoming of lacking the most economical solutions. In this pursuit, the present work envisages the development of an integrated design method for general wind farm power collection systems, which integrated the coupling random fork tree coding, union-find set loop identification, current and voltage drop calculation models, and a high performance optimization algorithm. The proposed coupling random fork tree coding, for the first time, realized the coupling code of the substation location, connection topology, and cable cross sections, providing the basis for the integration design of the power collection system. The optimization results for discrete and regular wind farms indicated that the proposed integration method achieved the best match of topology, substation location, and the cable cross sections, thus presenting the most economical scheme of the power collection system. Compared to the traditional two-step methods, the integration method used more branches while acquiring them, to maintain the lower number of wind turbines in each branch. Furthermore, it also employed large cross-section cables to reduce the energy loss caused by the impedance in the topology, thereby resulting in a slight increased cable cost; however, the total cost was minimized. The proposed method is very versatile and suitable for the optimization of power collection systems containing any number of wind turbines and substations, and can be combined with any evolutionary algorithm.
The comprehensive examination of typhoon impacts on offshore wind power in Chinese waters, which are prone to severe typhoons, remains largely unexplored. This paper takes a step toward assessing extreme design wind conditions for offshore wind turbines in Chinese waters and investigates typhoon-induced wind conditions considering their spatiotemporal effects. For this purpose, a spatiotemporal analysis framework for typhoons was proposed that includes a data-driven typhoon wind speed field model and estimation method of the extreme wind speed. The wind speed field model introduces a measured correction coefficient to enhance the generalization across various observed typhoons, thereby accurately capturing spatiotemporal typhoon effects. The analysis framework was applied to dozens of typical worst-case scenarios of typhoons passing through offshore wind farms in Chinese waters. These scenarios were selected based on typhoon observation data from the past 30 years. The quantitative analysis assesses and discusses the spatiotemporal impacts of typhoons on the mean wind speed, fluctuating wind speed, extreme wind speed, peak factor, and gust factor. The results indicate significant spatiotemporal impacts of typhoons on the inflow wind speed field. The maximum gust wind speed difference could exceed tenfold at various times or for different turbines. This study offers an interpretation of why wind turbines within the same wind farm may experience varying degrees of damage during identical typhoon attacks. By examining the spatiotemporal variation characteristics of typhoons and the corresponding induced wind speed fields, this paper highlights the significance of these factors for typhoon-resistant design in offshore wind farms, thus aiding in ensuring the structural safety of offshore wind turbines.
The present research envisages a method for calculating the dynamic responses of the wind turbines under typhoon. The measured power spectrum and inverse Fourier transform are used to generate the fluctuating wind field in the eyewall of the typhoon. Based on the beam theory, the unsteady aerodynamic model and the wind turbine dynamic model are coupled to calculate the dynamic response. Furthermore, using this method, the aeroelastic responses of a 6 MW wind turbine at different yaw angles are studied, and a 2 MW wind turbine are also calculated to verify the applicability of the results for different sizes of wind turbines. The results show that the turbulence characteristics of the fluctuating wind simulated by the proposed method is in good agreement with the actual measurement. Compared with the results simulated by the recommended power spectrum like the Kaimal spectrum, the energy distribution and variation characteristics simulated by the proposed method represent the real typhoon in a superior manner. It is found that the blade vibrates most violently at the inflow yaw angle of 30 degrees under the coupled effect of the aerodynamic, inertial and structural loads. In addition, the load on the tower exceeds the design limit values at the yaw angles of both 30 degrees and 120 degrees.