Gamma cameras are of great interest due to their high potential in the field of Nuclear Medicine Imaging. They allow for an early diagnosis of reduced size tumors, and also for a wide variety of preclinical studies with the aim of designing more effective treatments against cancer. In this work we propose a significantly improved multi-pinhole collimator gamma camera and perform a first Monte Carlo analysis of its characteristics. Maintaining the configuration of a multi-pinhole collimator with a high degree of overlapping (thus with a high sensitivity), we add a new element, an active septa, that besides acting as a collimator, is able to measure the impact coordinates of the incident photon. This way one is able to unambiguously identify through which pinhole any gamma ray passes before being detected. The result is a high sensitivity and resolution multi-pinhole gamma camera with an arbitrarily large field of view. As a consequence, the final reconstructed image does not suffer from the undesired artifacts or truncation associated to the multiplexing phenomenon. In this study we focus on the development of a system able to visualize in 3D tumors, nodes and metastasis in real time in the operating room with very low dose. We also briefly analyse and propose a novel design for a Single Photon Emission Computed Tomography system.
The development of dedicated positron emission tomography scanners is an active area of research, especially aiming at the improvement of lesion detection and in support of cancer treatment and management. Recently, dedicated Positron Emission Tomography (PET) systems with different configurations for specific organs have been developed for improving detection effectiveness. Open geometries are always subject to distortion and artifacts in the reconstructed images. Therefore, the aim of this work is to determine the optimal geometry for a novel cardiac PET system that will be developed by our team, and determine the time resolution needed to achieve reasonable image quality for the chosen geometry. The proposed geometries consist of 36 modules. These modules are arranged in two sets of two plates, each one with different configurations. We performed Monte Carlo simulations with different TOF resolutions, in order to test the image quality improvement in each case. Our results show, as expected, that increasing TOF resolution reduces distortion and artifact effects. We can conclude that a TOF resolution of the order of 200 ps is needed to reduce the artifacts, to acceptable levels, generated in the simulated cardiac-PET open geometries.
9 December 2022 in Zeitschrift für Medizinische Physik
The purpose of this study is to validate the PenRed Monte Carlo framework for clinical applications in brachytherapy. PenRed is a C++ version of Penelope Monte Carlo code with additional tallies and utilities. Six benchmarking scenarios are explored to validate the use of PenRed and its improved bachytherapy-oriented capabilities for HDR brachytherapy. A new tally allowing the evaluation of collisional kerma for any material using the track length kerma estimator and the possibility to obtain the seed positions, weights and directions processing directly the DICOM file are now implemented in the PenRed distribution. The four non-clinical test cases developed by the Joint AAPM-ESTRO-ABG-ABS WG-DCAB were evaluated by comparing local and global absorbed dose differences with respect to established reference datasets. A prostate and a palliative lung cases, were also studied. For them, absorbed dose ratios, global absorbed dose differences, and cumulative dose-volume histograms were obtained and discussed. The air-kerma strength and the dose rate constant corresponding to the two sources agree with the reference datatests within 0.3% (Sk) and 0.1% (Λ). With respect to the first three WG-DCAB test cases, more than 99.8% of the voxels present local (global) differences within ±1%(±0.1%) of the reference datasets. For test Case 4 reference dataset, more than 94.9%(97.5%) of voxels show an agreement within ±1%(±0.1%), better than similar benchmarking calculations in the literature. The track length kerma estimator scorer implemented increases the numerical efficiency of brachytherapy calculations two orders of magnitude, while the specific brachytherapy source allows the user to avoid the use of error-prone intermediate steps to translate the DICOM information into the simulation. In both clinical cases, only minor absorbed dose differences arise in the low-dose isodoses. 99.8% and 100% of the voxels have a global absorbed dose difference ratio within ±0.2% for the prostate and lung cases, respectively. The role played by the different segmentation and composition material in the bone structures was discussed, obtaining negligible absorbed dose differences. Dose-volume histograms were in agreement with the reference data. PenRed incorporates new tallies and utilities and has been validated for its use for detailed and precise high-dose-rate brachytherapy simulations.
Recently, two novel PET devices have been developed with open geometries, namely: breast and prostate-dedicated scanners. The breast-dedicated system comprises two detector rings of twelve modules with a field of view of 170 mm × 170 mm × 94 mm. Each module consists of a continuous trapezoidal LYSO crystal and a PSPMT. The system has the capability to vary the opening of the rings up to 60 mm in order to allow the insertion of a needle to perform a biopsy procedure. The prostate system has an open geometry consisting on two parallel plates separated 28 cm. One panel includes 18 detectors organized in a 6 × 3 matrix while the second one comprises 6 detectors organized in a 3 × 2 matrix. All detectors are formed by continuous LYSO crystals of 50 mm × 50 mm × 15 mm, and a SiPM array of 12 × 12 individual photo-detectors. The system geometry is asymmetric maximizing the sensitivity of the system at the prostate location, located at about 2/3 in the abdomen-anus distance. The reconstructed images for PET scanners with open geometries present severe artifacts due to this peculiarity. These artifacts can be minimized using Time Of Flight information (TOF). In this work we present a TOF resolution study for open geometries. With this aim, the dedicated breast and prostate systems have been simulated using GATE (8.1 version) with different TOF resolutions in order to determine the image quality improvements that can be achieved with the existing TOF-dedicated electronics currently present in the market. The images have been reconstructed using the LMOS algorithm including TOF modeling in the calculation of the voxel-Line Of Response emission probabilities.
17 January 2023 in International Journal of Radiation Biology
Purpose Some Monte Carlo simulation codes can read and write phase space files in IAEA format, which are used to characterize accelerators, brachytherapy seeds and other radiation sources. Moreover, as the format has been standardized, these files can be used with different simulation codes. However, MCNP6 has not still implemented this capability, which complicate the studies involving this kind of sources and the reproducibility of results among independent researchers. Therefore, the purpose of this work is to develop a tool to perform conversions between IAEA and MCNP6 phase space files formats, to be used for Monte Carlo simulations. Materials and Methods: This paper presents a toolkit written in C language that uses the IAEA libraries to convert phase space files between IAEA and MCNP6 format and vice versa. To test the functionality of the provided tool, a set of verification tests has been carried out. In addition, a linear accelerator treatment has been simulated with the PENELOPE library using the PenEasy framework, which is already capable to read and write IAEA phase space files, and MCNP6 using the developed tools. Results: Both codes show compatible depth dose curves and profiles in a water tank, demonstrating that the conversion tools work properly. Moreover, the phase space file formats have been converted from IAEA to MCNP6 format and back again to IAEA format, reproducing the very same results. Conclusion: The toolkit developed in this work offers MCNP6 scientific community an external and validated program able to convert phase space files in IAEA format to MCNP6 internal format and use them for Monte Carlo applications. Furthermore, the developed tools provide also the reverse conversion, which allow sharing MCNP6 results with users of other Monte Carlo codes. This capability in the MCNP6 ecosystem provides to the scientific community the ability not only to share radiation sources, but also to facilitate the reproducibility among different groups using different codes via the standard format specified by the IAEA.
Secondary neutrons are generated during proton therapy treatments, being a source of stray dose to the patient and personnel. Since the dose deposited by neutrons is directly related to their energy, determining their energy spectrum is crucial for the correct assessment of neutron doses. The aim of this work is to use Monte Carlo (MC) simulations to reproduce the generation of secondary stray neutrons in a proton therapy accelerator head and deconvolute their fluence energy spectrum using a Maximum Likelihood Expectation Maximization (MLEM) algorithm. This unfolding code utilizes a detector response to deconvolute spectra. Therefore, the response of a newly designed Extended Bonner Sphere Spectrometer (EBSS) mesh model, capable of detecting high-energy neutrons, has been evaluated by means of MC simulations. To deconvolute the neutron fluence energy spectrum with MLEM, the EBSS has been placed at 30 and 115 cm distance from the accelerator head in the direction of the proton beamline, and the secondary neutron fluence has been calculated in the volume of the detector. These measures served to unfold the MC simulated neutron fluence spectrum with absence of treatment room elements, by using the self-developed MLEM algorithm. The results indicate that a MLEM algorithm and MC simulations can be used as tools to assess neutron spectra in radiation therapies using protons.