The beam quality correction factor k
Q
for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of the International Code of Practice for dosimetry based on standards of absorbed dose to water (IAEA TRS 398). The values reported in this work agree with those in the literature within the uncertainty estimates and are to be included in the average values of the data obtained by different working groups for the forthcoming update of TRS 398.
1 July 2018 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
3 September 2021 in IEEE Access
A combination of distributed multi-tenant infrastructures, such as public Clouds and on-premises installations belonging to different organisations, are frequently used for scientific research because of the high computational requirements involved. Although resource sharing maximises their usage, it typically causes undesirable effects such as the noisy neighbour, producing unpredictable variations of the infrastructure computing capabilities. These fluctuations affect execution efficiency, even of loosely coupled applications, such as many Monte Carlo based simulation programs. This highlights the need of a service capable to handle workload distribution across multiple infrastructures to mitigate these unpredictable performance fluctuations. With this aim, this work introduces TaScaaS, a highly scalable and completely serverless service deployed on AWS to distribute loosely coupled jobs among several computing infrastructures, and load balance them using a completely asynchronous approach to cope with the performance fluctuations with minimum impact in the execution time. We demonstrate how TaScaaS is not only capable of handling these fluctuations efficiently, achieving reduction in execution times up to 45% in our experiments, but also split the jobs to be computed to meet the user-defined execution time.
16 December 2016 in Physics in Medicine & Biology
The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so that the absorbed dose in the two media can be related by their ratio of mass energy-absorption coefficients. In this work, an efficient way to correlate absorbed dose to water and absorbed dose to tissue in brachytherapy calculations at clinically relevant distances for low-energy photon emitting seeds is proposed. A correction is introduced that is based on the ratio of the water-to-tissue photon energy-fluences. State-of-the art Monte Carlo calculations are used to score photon fluence differential in energy in water and in various human tissues (muscle, adipose and bone), which in all cases include a realistic modelling of low-energy brachytherapy sources in order to benchmark the formalism proposed. The energy-fluence based corrections given in this work are able to correlate absorbed dose to tissue and absorbed dose to water with an accuracy better than 0.5% in the most critical cases (e.g. bone tissue).