Akiko Nishiyama

Dr. Akiko Nishiyama

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2022 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
TKTakumi Kobayashi
Takumi Kobayashi
ATAkifumi Takamizawa
Akifumi Takamizawa
DADaisuke Akamatsu
Daisuke Akamatsu
AKAkio Kawasaki
Akio Kawasaki
ANAkiko Nishiyama
Akiko Nishiyama
MYMasami Yasuda
Masami Yasuda
We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between a Yb171 optical lattice clock and a Cs133 fountain microwave clock that span 298 days with an uptime of 15.4%. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from 10−22 to 10−20  eV/c2 are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the Yb171 clock transition is also determined as 518 295 836 590 863.69(28) Hz, which is one of the important contributions toward a redefinition of the second in the International System of Units.

25 October 2016 in Optics Letters
Verified
Journal Article
Closed access
PDF file
AAAkifumi Asahara
Akifumi Asahara
ANAkiko Nishiyama
Akiko Nishiyama
SYSatoru Yoshida
Satoru Yoshida
KKKen-Ichi Kondo
Ken-Ichi Kondo
YNYoshiaki Nakajima
Yoshiaki Nakajima
KMKaoru Minoshima
Kaoru Minoshima
We demonstrate rapid characterization of complex optical properties of solids via dual-comb spectroscopy (DCS) in the near-infrared region. The fine spectral structures in the complex refractive index of an Er:YAG are successfully deduced using the developed system and Fourier analysis. Moreover, simultaneous determination of the refractive index and the thickness is demonstrated for a silicon semiconductor wafer through the use of multireflected echo signals. The results indicate the potential of DCS as a powerful measurement tool for the rapid and full characterization of solid materials.

28 October 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
ANAkiko Nishiyama
Akiko Nishiyama
SYSatoru Yoshida
Satoru Yoshida
YNYoshiaki Nakajima
Yoshiaki Nakajima
HSHiroyuki Sasada
Hiroyuki Sasada
KNKen’iChi Nakagawa
Ken’iChi Nakagawa
KMKaoru Minoshima
Kaoru Minoshima
We present a Doppler-free high-resolution dual-comb spectroscopy technique in which a dual-comb system is employed to perform optical-optical double-resonance (OODR) spectroscopy. In our experimental study, Doppler-free high-resolution and high-frequency-accuracy broadband measurements were realized using the proposed OODR dual-comb spectroscopic technique, which does not require high-power-per-mode frequency combs. We observed fully resolved hyperfine spectra of 5P3/2 - 4D5/2, 4D3/2 transitions of Rb at 1530 nm and precisely determined the absolute frequencies of the transitions, with an uncertainty of less than 1 MHz. The variations of the OODR spectral line shapes due to power broadening and alignment and the effects of polarization on the dual-comb OODR spectra were also analyzed. This study provides a widely applicable technique for Doppler-free dual-comb spectroscopy of various gaseous species.

12 June 2025 in Optica
Verified
Journal Article
Open access
TLThomas Lindvall
Thomas Lindvall
MPMarco Pizzocaro
Marco Pizzocaro
RGRachel M. Godun
Rachel M. Godun
MAMichel Abgrall
Michel Abgrall
DADaisuke Akamatsu
Daisuke Akamatsu
HMHelen S. Margolis
Helen S. Margolis
Optical clocks provide ultraprecise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time to our knowledge, while others had significantly lower uncertainties than previously achieved, supporting the advance toward a redefinition of the second and the use of optical standards for international time scales.

6 December 2017 in Optics Express
Verified
Journal Article
Closed access
PDF file
ANAkiko Nishiyama
Akiko Nishiyama
SYSatoru Yoshida
Satoru Yoshida
THTakuya Hariki
Takuya Hariki
YNYoshiaki Nakajima
Yoshiaki Nakajima
KMKaoru Minoshima
Kaoru Minoshima
In this study, we demonstrated an improvement in the detection sensitivity of dual-comb spectroscopy using the repetition rate multiplication of optical frequency combs. We compared the dual-comb signals in three dual-comb setups consisting of combinations of two combs with and without mode-filtering, and investigated how the repetition rate influences the signal-to-noise ratio (SNR) of dual-comb measurements. The dual-comb setups using high-repetition-rate combs enabled the absorption lines of HCN gas to be measured with a high SNR in a short averaging time, and real-time spectral data acquisition was realized using a low-sensitivity and low-resolution RF spectrum analyzer.

28 March 2018 in Optics Express
Verified
Journal Article
Closed access
ANAkiko Nishiyama
Akiko Nishiyama
YNYoshiaki Nakajima
Yoshiaki Nakajima
KNKen’iChi Nakagawa
Ken’iChi Nakagawa
KMKaoru Minoshima
Kaoru Minoshima
We demonstrated Doppler-free two-photon absorption dual-comb spectroscopy of 5S(1/2) - 5D(5/2) and 5D(3/2) transitions of Rb. We employed simple pulse-shaping of the dual-comb source and eliminated Doppler-broadening backgrounds, which cause fitting errors of the Doppler-free signals. Moreover, to improve sensitivity, we investigated the coherence in dual-comb fluorescence signals and the coherent averaging method was applied to fluorescence dual-comb detection for the first time. The detection sensitivity was significantly improved by coherent averaging to reduce the noise floor. Observed Doppler-free spectra was fitted to Voigt profiles and we performed absolute frequency determination with a precision of about 100 kHz. (c) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement