Akifumi Takamizawa

Akifumi Takamizawa

Auto-generated profile, based on publicly available information

Akifumi Takamizawa

National Metrology Institute of Japan National Institute of Advanced Industrial Science and Technology (AIST) 1-1-1 Umezono 305-8563 Tsukuba Ibaraki Japan

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2022 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
TKTakumi Kobayashi
Takumi Kobayashi
ATAkifumi Takamizawa
Akifumi Takamizawa
DADaisuke Akamatsu
Daisuke Akamatsu
AKAkio Kawasaki
Akio Kawasaki
ANAkiko Nishiyama
Akiko Nishiyama
MYMasami Yasuda
Masami Yasuda
We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between a Yb171 optical lattice clock and a Cs133 fountain microwave clock that span 298 days with an uptime of 15.4%. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from 10−22 to 10−20  eV/c2 are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the Yb171 clock transition is also determined as 518 295 836 590 863.69(28) Hz, which is one of the important contributions toward a redefinition of the second in the International System of Units.

27 February 2009 in Optics Letters
Verified
Journal Article
Closed access
PDF file
FHFeng-Lei Hong
Feng-Lei Hong
MMM. Musha
M. Musha
MTM. Takamoto
M. Takamoto
HIH. Inaba
H. Inaba
SYS. Yanagimachi
S. Yanagimachi
HKH. Katori
H. Katori
We demonstrate a precision frequency measurement using a phase-stabilized 120 km optical fiber link over a physical distance of 50 km. The transition frequency of the Sr87 optical lattice clock at the University of Tokyo is measured to be 429228004229874.1(2.4) Hz referenced to international atomic time. The results demonstrate the excellent functions of the intercity optical fiber link and the great potential of optical lattice clocks for use in the redefinition of the second.

15 November 2015 in Journal of the Physical Society of Japan
Verified
Journal Article
Closed access
TTTakehiko Tanabe
Takehiko Tanabe
DADaisuke Akamatsu
Daisuke Akamatsu
TKTakumi Kobayashi
Takumi Kobayashi
ATAkifumi Takamizawa
Akifumi Takamizawa
SYShinya Yanagimachi
Shinya Yanagimachi
KHKazumoto Hosaka
Kazumoto Hosaka
We performed an absolute frequency measurement of the 1S0–3P0 transition in 87Sr with a fractional uncertainty of 1.2 × 10−15, which is less than one-third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.

27 August 2014 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ATAkifumi Takamizawa
Akifumi Takamizawa
SYShinya Yanagimachi
Shinya Yanagimachi
TTTakehiko Tanabe
Takehiko Tanabe
KHKen Hagimoto
Ken Hagimoto
IHIku Hirano
Iku Hirano
JHJohn G. Hartnett
John G. Hartnett
The frequency stability of an atomic fountain clock was significantly improved by employing an ultra-stable local oscillator and increasing the number of atoms detected after the Ramsey interrogation, resulting in a measured Allan deviation of 8.3 × 10 -14τ-1/2 . A cryogenic sapphire oscillator using an ultra-low-vibration pulse-tube cryocooler and cryostat, without the need for refilling with liquid helium, was applied as a local oscillator and a frequency reference. High atom number was achieved by the high power of the cooling laser beams and optical pumping to the Zeeman sublevel mF = 0 employed for a frequency measurement, although vapor-loaded optical molasses with the simple (001) configuration was used for the atomic fountain clock. The resulting stability is not limited by the Dick effect as it is when a BVA quartz oscillator is used as the local oscillator. The stability reached the quantum projection noise limit to within 11%. Using a combination of a cryocooled sapphire oscillator and techniques to enhance the atom number, the frequency stability of any atomic fountain clock, already established as primary frequency standard, may be improved without opening its vacuum chamber.

13 February 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
KWKen-Ichi Watabe
Ken-Ichi Watabe
TITakeshi Ikegami
Takeshi Ikegami
ATAkifumi Takamizawa
Akifumi Takamizawa
SYShinya Yanagimachi
Shinya Yanagimachi
SOShin-Ichi Ohshima
Shin-Ichi Ohshima
SKSvenja Knappe
Svenja Knappe
High-contrast coherent population trapping signals were observed on the Cs D1 line by use of a bichromatic linear polarized light (lin‖lin field). A maximum absorption contrast of about 10% was obtained. This was nearly twice as high as that measured with the standard configuration of bichromatic circularly polarized light (σ−σ field). The results are compared with density matrix calculations of 4 and 5 level systems.

30 March 2013 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
KSKrzysztof Szymaniec
Krzysztof Szymaniec
HNHeung-Ryoul Noh
Heung-Ryoul Noh
SPSang Eon Park
Sang Eon Park
ATAkifumi Takamizawa
Akifumi Takamizawa