7 December 2022 in Physical Review Letters
We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between a optical lattice clock and a fountain microwave clock that span 298 days with an uptime of 15.4%. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from to are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the clock transition is also determined as 518 295 836 590 863.69(28) Hz, which is one of the important contributions toward a redefinition of the second in the International System of Units.
27 February 2009 in Optics Letters
We demonstrate a precision frequency measurement using a phase-stabilized optical fiber link over a physical distance of . The transition frequency of the optical lattice clock at the University of Tokyo is measured to be referenced to international atomic time. The results demonstrate the excellent functions of the intercity optical fiber link and the great potential of optical lattice clocks for use in the redefinition of the second.
15 November 2015 in Journal of the Physical Society of Japan
We performed an absolute frequency measurement of the 1S0–3P0 transition in 87Sr with a fractional uncertainty of 1.2 × 10−15, which is less than one-third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.
27 August 2014 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
The frequency stability of an atomic fountain clock was significantly improved by employing an ultra-stable local oscillator and increasing the number of atoms detected after the Ramsey interrogation, resulting in a measured Allan deviation of 8.3 × 10 -14τ-1/2 . A cryogenic sapphire oscillator using an ultra-low-vibration pulse-tube cryocooler and cryostat, without the need for refilling with liquid helium, was applied as a local oscillator and a frequency reference. High atom number was achieved by the high power of the cooling laser beams and optical pumping to the Zeeman sublevel mF = 0 employed for a frequency measurement, although vapor-loaded optical molasses with the simple (001) configuration was used for the atomic fountain clock. The resulting stability is not limited by the Dick effect as it is when a BVA quartz oscillator is used as the local oscillator. The stability reached the quantum projection noise limit to within 11%. Using a combination of a cryocooled sapphire oscillator and techniques to enhance the atom number, the frequency stability of any atomic fountain clock, already established as primary frequency standard, may be improved without opening its vacuum chamber.
13 February 2009 in Applied Optics
High-contrast coherent population trapping signals were observed on the Cs line by use of a bichromatic linear polarized light ( field). A maximum absorption contrast of about 10% was obtained. This was nearly twice as high as that measured with the standard configuration of bichromatic circularly polarized light ( field). The results are compared with density matrix calculations of 4 and 5 level systems.
30 March 2013 in Applied Physics B