Kazihiko Endo

Prof. Kazihiko Endo


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
NKNaoyuki Kaga
Naoyuki Kaga
FNFutami Nagano-Takebe
Futami Nagano-Takebe
TNTakashi Nezu
Takashi Nezu
TMTakashi Matsuura
Takashi Matsuura
KEKazihiko Endo
Kazihiko Endo
MKMasayuki Kaga
Masayuki Kaga
This study was aimed at investigating the protective effects of glass ionomer cement (GIC) and surface pre-reacted glass ionomer (S-PRG) fillers used as dental restorative materials on demineralization of bovine enamel. GlasIonomer FX ULTRA (FXU), Fuji IX GP Extra (FIXE), CAREDYNE RESTORE (CDR) were used as GICs. PRG Barrier Coat (BC) was used as the S-PRG filler. They were incubated in a lactic acid solution (pH = 4.0) for six days at a temperature of 37 °C. The mineral was etched from the enamel surface, and a large number of Ca and P ions were detected in solution. The Al, F, Na, Sr, and Sr ions were released in GICs and S-RPG fillers. The Zn ion was released only in CDR and the B ion was released only in BC. The presence of apparent enamel prism peripheries was observed after six days of treatment for the group containing only enamel blocks. pH values for the FXU, FIXE, CDR, BC, and enamel block groups after six days were 6.5, 6.6, 6.7, 5.9, and 5.1, respectively. Therefore, the observed pH neutralization effect suppressed progression of caries due to the release of several ions from the restoratives.

Verified
Journal Article
Open access
PDF file
CLChia-Cheng Lin
Chia-Cheng Lin
MIMasahiro Ishikawa
Masahiro Ishikawa
TMTakeo Maida
Takeo Maida
HCHsin-Chung Cheng
Hsin-Chung Cheng
KOKeng-Liang Ou
Keng-Liang Ou
KEKazihiko Endo
Kazihiko Endo
A distal free-end situation could result in insufficient stability of the surgical guide, and could reduce accuracy of the static guided implant surgery (sGIS). The purpose of this study was to investigate the accuracy of sGIS using a combination tooth-and-bone supported stereolithographic (SLA) surgical guide in distal extension situation. Thirty dentists, each placed three implants at the Federal Dentaire Internationale (FDI) teeth positions #46, #47 (a distal extension situation), and #36 (a single tooth gap) via the surgical guide on a model fixed to a manikin. Pre- and post-operative computed tomography (CT) images of the models were superimposed, and the positional and angular deviations of the implants were measured with metrology software. An analysis of variance (ANOVA) test was performed to evaluate the intergroup differences. No significant differences were found for all the positional and angular deviations among the three implant sites, except the bucco-lingual deviation at the implant platform in the #47 position (0.43 ± 0.19 mm) that was significantly larger than the #46 (0.21 ± 0.14 mm) and #36 (0.24 ± 0.25 mm) positions (p < 0.0001). Within the limits of this study, we conclude that, in distal extension situation of missing mandibular molars, adding a bone-supported strut in the distal part of the surgical guide can be beneficial to the accuracy of the sGIS.

1 July 2006 in The Angle Orthodontist
Verified
Journal Article
Closed access
MIMasahiro Iijima
Masahiro Iijima
KEKazihiko Endo
Kazihiko Endo
TYToshihiro Yuasa
Toshihiro Yuasa
HOHiroki Ohno
Hiroki Ohno
KHKazuo Hayashi
Kazuo Hayashi
IMItaru Mizoguchi
Itaru Mizoguchi
The purpose of this study was to provide a quantitative assessment of galvanic corrosion behavior of orthodontic archwire alloys coupled to orthodontic bracket alloys in 0.9% NaCl solution and to study the effect of surface area ratios. Two common bracket alloys, stainless steels and titanium, and four common wire alloys, nickel-titanium (NiTi) alloy, beta-titanium (beta-Ti) alloy, stainless steel, and cobalt-chromium-nickel alloy, were used. Three different area ratios, 1:1, 1:2.35, and 1:3.64, were used; two of them assumed that the multibracket appliances consists of 14 brackets and 0.016 inch of round archwire or 0.016 x 0.022 inch of rectangular archwire. The galvanic current was measured for 3 successive days using zero-impedance ammeter. When the NiTi alloy was coupled with Ti (1:1, 1:2.35, and 1:3.64 of the surface area ratio) or beta-Ti alloy was coupled with Ti (1:2.35 and 1:3.64 of the surface area ratio), Ti initially was the anode and corroded. However, the polarity reversed in 1 hour, resulting in corrosion of the NiTi or beta-Ti. The NiTi alloy coupled with SUS 304 or Ti exhibited a relatively large galvanic current density even after 72 hours. It is suggested that coupling SUS 304-NiTi and Ti-NiTi may remarkably accelerate the corrosion of NiTi alloy, which serves as the anode. The different anode-cathode area ratios used in this study had little effect on galvanic corrosion behavior.

15 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CLChia-Cheng Lin
Chia-Cheng Lin
MIMasahiro Ishikawa
Masahiro Ishikawa
BHBai-Hung Huang
Bai-Hung Huang
MHMao-Suan Huang
Mao-Suan Huang
HCHsin-Chung Cheng
Hsin-Chung Cheng
KEKazihiko Endo
Kazihiko Endo
Studies examining the effect of operator experience on the accuracy of static guided implant surgery have used postoperative computed tomography (CT) images to measure the error, with inconsistent results. The purpose of this study was to try to clarify this issue by using a measurement method based on the postoperative optical scan. Thirty dentists were divided into an experienced group and an inexperienced group. On a partially edentulous mandibular model in the manikin head, each dentist placed three implants via the stereolithographic (SLA) surgical guide. The implant positions were identified by a desktop scanner and compared with the planned positions using a metrology software program. No statistically significant differences were observed for any of the measured positional and angular deviations of the three implant sites between experienced and inexperienced operators (p > 0.01). All the mean values of deviations of the inexperienced group, except the depth deviation, were less than the experienced group. Implants inserted by dentists under 40 years old had significantly better accuracy than senior doctors in the global deviation at implant apex (p = 0.006). Within the limits of this study, we concluded that operator experience is not a critical factor in achieving the accuracy of guided implant surgery via the tooth-supported SLA surgical guide. Large deviations could occur even with the aid of the SLA surgical guide, and care must be taken to avoid errors for both experienced and inexperienced operators.

1 January 1998 in Corrosion Engineering
Verified
Journal Article
Closed access
KEKazihiko Endo
Kazihiko Endo
YAYoshihiro Abiko
Yoshihiro Abiko
MSMasahiro Suzuki
Masahiro Suzuki
HOHiroki Ohno
Hiroki Ohno
TKTohru Kaku
Tohru Kaku

1 January 2000 in Dental Materials Journal
Verified
Journal Article
Open access
KEKazihiko Endo
Kazihiko Endo
MSMasahiro Suzuki
Masahiro Suzuki
HOHiroki Ohno
Hiroki Ohno
The corrosion behaviors of four ferric stainless steels and two austenitic stainless steels were examined in a simulated physiological environment (0.9% NaCl solution) to obtain basic data for evaluating the appropriate composition of stainless steels for dental magnetic attachments. The corrosion resistance was evaluated by electrochemical techniques and the analysis of released metal ions by atomic absorption spectrophotometry. The surface of the stainless steels was analyzed by X-ray photoelectron spectroscopy (XPS). The breakdown potential of ferric stainless steels increased and the total amount of released metal ions decreased linearly with increases in the sum of the Cr and Mo contents. The corrosion rate of the ferric stainless steels increased 2 to 6 times when they were galvanically coupled with noble metal alloys but decreased when coupled with commercially pure Ti. For austenitic stainless steels, the breakdown potential of high N-bearing stainless steel was approximately 500 mV higher than that of SUS316L, which is currently used as a component in dental magnetic attachments. The enriched nitrogen at the alloy/passive film interface may be effective in improving the localized corrosion resistance.