In order to prevent electric shock accidents during the maintenance and repair of high-voltage direct current (DC) live equipment, an intelligent safety early warning system device based on non-contact electric field measurement is developed in this paper, to ensure the life safety of electrical workers and the stable operation of equipment. Firstly, the self-developed electric field sensor is used to measure the electric field strength of the space around the charged device. The STM32 microprocessor in the sensor will compare the measured electric field value with a preset safety threshold. If the safety threshold is exceeded, the early warning device issues an audible alarm. It prompts the electric power operator to exit to a safe distance. In addition, the alarm prompt symbol and the real-time waveform of the measured electric field can be seen intuitively on the mobile smart APP interface. Secondly, for devices with different voltage levels, the sensor electric field measurement range and sensitivity can be dynamically adjusted by changing the motor speed. In addition, according to the voltage level identification algorithm, this is also to achieve an adaptive safety early warning of different live equipment. Finally, field experiments were performed at a ±500 kV DC converter station and an ±800 kV DC transmission line experimental platform. The measured values of the electric field are basically consistent with the simulated values, and the safety early warning device has no false positives or false negatives during the test. The experimental results show that the design of the safety warning device in this paper meets the actual needs, and it can alert the electric workers to the specified safety distance.
Disconnect switch and circuit breakers operations in gas insulated switchgear (GIS) systems may produce very fast transient overvoltage (VFTO). Detecting VFTO is the first step for researchers to reduce the damage to other equipment of the substation caused by VFTO. Most of the existing sensors used for VFTO are generally bulky, complex to install, and require modification of the GIS structure. In this paper, a miniaturized measurement system that uses capacitive voltage divider and differentiating–integrating circuit is proposed. A special sensor structure and optimized differentiating–integrating circuit components arrangement were designed to increase the bandwidth of the measurement system. The frequency-domain, time-domain and voltage divide calibration experiment was performed, and a comparison experiment with an internal VFTO sensor was conducted. The measurement system was applied in the 500 kV GIS substation, and the VFTO measurement under specific conditions was carried out. The measured time domain and frequency domain waveforms conformed to the definition of standard VFTO according to IEC 60,071. It was found that the proposed measurement system meets VFTO measurement requirements and can be applied to actual VFTO measurements.
The traditional method of using electric field sensors to realize early warning of electric power safety distance cannot measure the distance of dangerous sources. Therefore, aiming at the electric field with a frequency of 50 to 60 Hz (AC electric field), a new method for localization of aerial AC target by the capacitive one-dimensional spherical electric field sensor circular array is studied. This method can directly calculate the distance, elevation, and azimuth of the detector from the dangerous source. By combining the measurement principle of the spherical electric field sensor and the plane circular array theory, a mathematical model for the localization of aerial targets in an AC electric field is established. An error model was established using Gaussian noise and the effects of different layout parameters on the localization error were simulated. Based on mutual interference between sensors, minimum induced charge, and localization error, an optimal model for sensor layout was established, and it was solved by using genetic algorithms. The optimization results show that when the number of sensors is 4, the array radius is 20 cm, and the sensor radius is 1.5 cm, the ranging error is 8.4%. The detector was developed based on the layout parameters obtained from the optimization results, and the localization method was experimentally verified at 10 and 35 kV alarm distances. The experimental results show that when the detector is located at 10 kV alarm distance, the distance error is 0.18 m, the elevation error is 6.8°, and the azimuth error is 4.57°, and when it is located at 35 kV alarm distance, the distance error is 0.2 m, the elevation error is 4.8°, and the azimuth error is 5.14°, which meets the safety distance warning requirements of 10 and 35 kV voltage levels.