Xiangyu Tan

Xiangyu Tan

Auto-generated profile, based on publicly available information

Xiangyu Tan

Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2022 in Electronics
Verified
Journal Article
Open access
PDF file
QTQinghua Tan
Qinghua Tan
WZWenbin Zhang
Wenbin Zhang
XTXiangyu Tan
Xiangyu Tan
LYLe Yang
Le Yang
RRrenyanan ren
renyanan ren
YHYang Hu
Yang Hu
Compared with the traditional Rogowski coil, printed circuit board (PCB) Rogowski coil has the advantages of high measurement accuracy, simple manufacturing process and low cost. It has become an important device in current measurement. However, the existing PCB Rogowski coils are mostly closed, and the open-ended structure PCB Rogowski coils are susceptible to external magnetic field interference. This paper proposes an open-ended structure PCB Rogowski coil based on a new winding method, so that the two open-ended PCB Rogowski coils are evenly distributed when closed, while improving the coil’s immunity to external magnetic fields based on the winding method of equal area of the de-wired and loop. In addition, this paper uses the hybrid integration circuit and the back-end matching method to achieve the broadband measurement performance of the sensor. Finally, the experimental results show that the mutual inductance difference between the closed and open-ended structure PCB Rogowski coil is less than 0.5% under the same wiring mode. Under the equivalent current interference at 50 mm from the measured current, the maximum interference coefficient of the open-ended structure coil is 1.45%; in sine sweep and pulse current test conditions, the frequency band is 34 Hz–3.5 MHz.

31 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LWLizhe Wang
Lizhe Wang
WZWenbin Zhang
Wenbin Zhang
XTXiangyu Tan
Xiangyu Tan
WCWeiren Chen
Weiren Chen
SLShiqi Liang
Shiqi Liang
CSChunguang Suo
Chunguang Suo
Disconnect switch and circuit breakers operations in gas insulated switchgear (GIS) systems may produce very fast transient overvoltage (VFTO). Detecting VFTO is the first step for researchers to reduce the damage to other equipment of the substation caused by VFTO. Most of the existing sensors used for VFTO are generally bulky, complex to install, and require modification of the GIS structure. In this paper, a miniaturized measurement system that uses capacitive voltage divider and differentiating–integrating circuit is proposed. A special sensor structure and optimized differentiating–integrating circuit components arrangement were designed to increase the bandwidth of the measurement system. The frequency-domain, time-domain and voltage divide calibration experiment was performed, and a comparison experiment with an internal VFTO sensor was conducted. The measurement system was applied in the 500 kV GIS substation, and the VFTO measurement under specific conditions was carried out. The measured time domain and frequency domain waveforms conformed to the definition of standard VFTO according to IEC 60,071. It was found that the proposed measurement system meets VFTO measurement requirements and can be applied to actual VFTO measurements.

16 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CSChunguang Suo
Chunguang Suo
JZJiawen Zhao
Jiawen Zhao
WZWenbin Zhang
Wenbin Zhang
PLPeng Li
Peng Li
RHRujin Huang
Rujin Huang
XTXiangyu Tan
Xiangyu Tan
The tracking and positioning of transmission lines is a key element for UAVs (Unmanned Aerial Vehicles) to achieve autonomous inspection of transmission lines. Current methods are vulnerable to weather and environmental factors, have high costs, and have difficulties in data processing. Therefore, this paper proposes a transmission line tracking and localization method based on the electric field sensor array, which calculates the current UAV’s heading angle deflection angle, the distance between the transmission line and the UAV, and the elevation angle, providing a new idea to solve the problem of UAV inspection of transmission lines. At the same time, the electric field distribution of different arrangements of three-phase transmission lines was analyzed using COMSOL to determine the flight area of the UAV. By comparing the electric field distribution of the UAV flight area and single-phase transmission lines, it was verified that the current method is also applicable in the three-phase transmission line scenario, and it was further verified that the sensor array used can sense the change of the UAV position in the flight area, indicating that the electric field sensor array can realize the transmission line tracking and localization of transmission lines. The experimental results showed that, in the three-phase transmission line scenario, when the sensor array moves along the transmission straight wire, the maximum absolute error of the heading angle deflection angle calculated according to this method was 8.2°, the maximum absolute error of the distance between the array and the transmission line was 19.3 cm, and the maximum absolute error of the elevation angle was 11.37°; the error was within a reasonable range and can be used for the UAV to realize autonomous inspection.

29 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
XTXiangyu Tan
Xiangyu Tan
YLYuan Liu
Yuan Liu
SSSun Ningbo Sun
Sun Ningbo Sun
WZWenbin Zhang
Wenbin Zhang
This paper proposes an integrated sensor for voltage and current distribution network insulators, based on electric field coupling and TMR magnetic sensing, to address the issues of traditional voltage and current separation measurement, insulator safety after primary and secondary fusion, uncertainty in voltage measurement gain, and interference resistance in TMR current measurements. Through simulation and optimization, the design of the embedded voltage-sensing unit in the insulator is achieved, ensuring uniform electric field distribution, determining the transfer function, and minimizing partial discharge, thereby ensuring insulator safety and improving voltage measurement accuracy. Additionally, a self-integrating circuit design is used to widen the low-frequency dynamic range and increase the voltage division ratio. Moreover, an open-type two-stage magnetic ring current sensor based on TMR is proposed, with optimized magnetic ring dimensions to detect currents from low to medium ranges, addressing eccentricity errors and improving sensitivity, immunity to interference, and magnetic field uniformity. The experimental results show that this integrated sensor can effectively ensure measurement accuracy, stability, and dynamic range.