Qian Huang

Dr. Qian Huang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2015 in Journal of Dispersion Science and Technology
Verified
Journal Article
Closed access
CLChangjun Li
Changjun Li
QHQian Huang
Qian Huang
SMShufeng Ma
Shufeng Ma
CJChuling Ji
Chuling Ji
Water-in-oil (W/O) emulsions are very common in the petroleum industry, and their viscosities are the principle parameters for the operation design. Typical correlations composed by one or two factors cannot always fit the apparent viscosity of W/O emulsions very well, especially when applied to the crude oil/water emulsions. The viscosities of W/O emulsions, which were made from three kinds of crude oil, were measured by Anton Paar MCR302 viscometer at atmospheric pressure with different temperatures as well as shear rates. The experiment results indicate that W/O emulsion would exhibit Newtonian characteristic when water content is no higher than 0.2 and non-Newtonian characteristic otherwise. According to the experimental data, a modified correlation based on the Broughton–Squires model and Ronningsen model was introduced to predict the viscosity of W/O emulsions, and the comparison results showed that the new modified correlation has better accuracy than the original models.

4 March 2016 in Journal of Dispersion Science and Technology
Verified
Journal Article
Closed access
CLChangjun Li
Changjun Li
QHQian Huang
Qian Huang
A mechanical separation process in a de-oiling hydrocyclone is described in which disperse oil droplets are separated from a continuous water phase. This separation process is influenced by droplet breakage and coalescence. Based on experimental data and simulation results in a stirred tank, a modified breakage model, which can be applied to droplet breakage in the de-oiling hydrocyclone, is developed. Then, a simulation model is developed coupling the numerical solution of the flow field in the hydrocyclone based on computational fluid dynamics (CFD) with population balances. The homogenous discrete method and the inhomogeneous discrete method are applied for solving the population balance model (PBM). The investigations show that the numerical results obtained by the simulation model coupled with the modified PBM using the inhomogeneous discrete method are in good accordance with experimental data under a high flow rate. According to this simulation model, the effect of three different inlet designs on the separation efficiency of the de-oiling hydrocyclone has been discussed. The results indicate that the separation efficiency of the de-oiling hydrocyclone can be improved with an appropriate inlet design.

19 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
QHQian Huang
Qian Huang
XLXueyuan Long
Xueyuan Long
A modified computational fluid dynamic (CFD) model has been developed to obtain oil removal efficiency for oily wastewater treatment in large-scale flotation tanks. According to the investigation of oil droplet/bubble interactions in a flotation tank, a modified Bloom–Heindel model is used to calculate the collision and attachment efficiencies between oil droplets and bubbles. Effects of the gas flow rate, oil diameter and oil concentration on oil removal efficiency of flotation tank were analyzed experimentally. The application scope of this modified CFD model is evaluated using experimental results. In addition, the comparison between the existing model and the modified model demonstrates that this modified CFD model can make a good prediction for the separation performance of the flotation tank.

3 February 2016 in Chemical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
CLChangjun Li
Changjun Li
QHQian Huang
Qian Huang

8 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
QHQian Huang
Qian Huang
RWRuiLin Wang
RuiLin Wang
JHJingxi Hu
Jingxi Hu
HJHao Jiao
Hao Jiao
CZChi Zhang
Chi Zhang
LLLiangchen Lv
Liangchen Lv
As a branch of nondestructive testing (NDT), Pulsed Eddy Current Testing (PECT) is characterized by its wide frequency spectrum and high penetration depth. After years of development, it has been widely applied to defect detection and material characterization of key components in industries such as petrochemicals, new energy, and aerospace. With the large-scale application of new energy sources like liquefied natural gas (LNG), methanol, and liquid hydrogen, the demand for NDT of non-ferromagnetic materials (e.g., austenitic stainless steel) has surged. However, challenges such as electromagnetic leakage caused by low magnetic permeability and the lift-off effect induced by protective layers impose stricter requirements on inspection technologies, driving the evolution of PECT towards adaptability in complex scenarios. This paper systematically reviews the latest advances in PECT technology, covering detection sensors, modeling methods, detection signal processing, and engineering applications. With a particular emphasis on research outcomes from the past decade, this paper also proposes potential directions for future development, aiming to provide a reference for innovative research and the industrial promotion of PECT technology.

15 February 2017 in Journal of Dispersion Science and Technology
Verified
Journal Article
Closed access
QHQian Huang
Qian Huang
CLChangjun Li
Changjun Li
PLPing Li
Ping Li
The de-oiling hydrocyclone is among the most effective devices to recover oil from oily wastewater. In this work, a new model is theoretically developed to predict the separation efficiency of oil droplets in hydrocyclones. According to the analysis of the flow pattern, the droplet dynamics, and oil concentration distribution in the de-oiling hydrocyclone, the differential equation for the new model is established based on the principle of the mass balance of oil droplet. The proposed model can be finally expressed as a simple explicit function including the main geometrical dimensions and operating parameters. The availability of this model is validated by comparison of the calculated grade efficiency with experimental data and other theoretical separation model. GRAPHICAL ABSTRACT