For the sake of environmental protection and circular economy, cement reduction and cement substitutes have become popular research topics, and the application of green materials has become an important issue in the development of building materials. This study developed green pervious concrete using water-quenched blast-furnace slag (BFS) and co-fired fly ash (CFFA) to replace cement. The objectives of this study were to gauge the feasibility of using a non-cement binder in pervious concrete and identify the optimal binder mix design in terms of compressive strength, permeability, and durability. For filled percentage of voids by cement paste (FPVs) of 70%, 80%, and 90%, which mixed with CFFA and BFS as the binder (40 + 60%, 50 + 50%, and 60 + 40%) to create pervious concrete with no cement. The results indicate that the complete (100%) replacement of cement with CFFA and BFS with no alkaline activator could induce hydration, setting, and hardening. After a curing period of 28 days, the compressive strength with different FPVs could reach approximately 90% that of the control cement specimens. The cementless pervious concrete specimens with BFS:CFFA = 7:3 and FPV = 90% presented better engineering properties and permeability.
Three-dimensional printing is an emerging technique that has received significant attention in the construction industry. This study presents an investigation into the printing and hardened properties of 3D-printed concrete (3DPC). Both fly ash (FA) and ground granulated blast furnace slag (GGBFS) were used to replace cement in different ratios (0%, 25%, and 50%) to produce 3DPC. Extrudability and buildability tests were performed to evaluate the effects of FA and GGBFS in various proportions on the printing properties of 3DPC. Additionally, the hardened properties of 3DPC were determined. Test results show that all mix designs meet the printing requirements of 3DPC. The specimens with a higher proportion of GGBFS exhibited higher unit weight and compressive and flexural strength, but lower water absorption and drying shrinkage. The compressive and flexural strength of 3DPC in the printing direction were the highest, outperforming those of the cast specimens at the age of 28 days. Our results indicate that FA and GGBFS can be used to replace 50% of the cement in 3DPC.
This study investigates the use of finely ground coal bottom ash (FGCBA) as a substitute for Portland cement in concrete, comparing it with coal fly ash from the same power plant. The incorporation of this ash necessitates the addition of a superplasticizer to achieve the desired slump at the same replacement rate. The results demonstrate that at an optimal 20% replacement rate, as determined by 91-day compressive strength tests, the maximum strength achieved by FGCBA is 97.7% of the control group with pure cement, whereas coal fly ash reaches 114.0%. Drying shrinkage tests indicate for both materials have similar volume stability, while rapid chloride permeability tests show their effectiveness in reducing chloride ion permeability, with superior performance from FGCBA. Under optimal conditions, the result of the RCPT test was only 559 coulombs, which is significantly better compared to the 4108 coulombs when using fly ash from coal combustion. Our results demonstrate that utilizing low-cost bottom ash by finely grinding it to replace Portland cement in concrete is feasible, achieving both carbon reduction and economic viability.
Green concrete (GC) was developed for realizing sustainable development, recycling waste materials, and reducing environmental pollution. For the practical use of GC, various harmful materials must blocked from entering its cracks and pores; and its strength and durability must be improved. The use of an inorganic coating material (ICM) for GC effectively prevents the intrusion of harmful materials and repairs the concrete. ICMs can reduce the permeability and increase the durability of concrete. This study investigated GC, construction waste, and ICMs and used recycled sand and gravel as well as construction waste as substitutes for cement. The results indicate that the coarse aggregate substitution, water-binder ratio, and recycled fine aggregate substitution must be controlled suitably in GC. Furthermore, the coating layer, fine aggregate substitution, and aging of the ICM mut be controlled suitably. GC with an ICM showed poorer performance than conventional concrete, mainly because of the high porosity. Nonetheless, the ICM somewhate reduces the porosity and resists the penetration of chloride ions, thereby promoting concrete quality.