Increasing use of the ground as a thermal reservoir is expected in the near future. Shallow geothermal energy (SGE) systems have proved to be sustainable alternative solutions for buildings and infrastructure conditioning in many areas across the globe in the past decades. Recently novel solutions, including energy geostructures, where SGE systems are coupled with foundation heat exchangers, have also been developed. The performance of these systems is dependent on a series of factors, among which the thermal properties of the soil play a major role. The purpose of this paper is to present, in an integrated manner, the main methods and procedures to assess ground thermal properties for SGE systems and to carry out a critical review of the methods. In particular, laboratory testing through either steady-state or transient methods are discussed and a new synthesis comparing results for different techniques is presented. In situ testing including all variations of the thermal response test is presented in detail, including a first comparison between new and traditional approaches. The issue of different scales between laboratory and in situ measurements is then analysed in detail. Finally, the thermo-hydro-mechanical behaviour of soil is introduced and discussed. These coupled processes are important for confirming the structural integrity of energy geostructures, but routine methods for parameter determination are still lacking.
9 October 2013 in European Journal of Environmental and Civil Engineering
Soil cracking has been studied for many decades; however, it still deserves further investigation. This paper describes a new testing device that uses image processing to perform simultaneous and continuous quantification of the vertical strain and radial strain, crack area, and water content of a soil specimen subjected to suction cycles imposed by the vapour equilibrium method. An image processing method was designed to determine the crack area and the soil radial strain separately. The evolution of each measured parameter over time in a clayey soil specimen subjected to 3 suction cycles is presented and discussed. The first suction cycle has the greatest impact on the crack area, the mass water content, the vertical strains and the radial strains. Hysteresis loops were observed for crack area and radial strain evolution.
Soil thermal properties are needed in specific engineering applications, such as the design of high-level radioactive waste disposal, buried power transmission cables and geothermal systems. The propagation of the heat flow in a soil exposed to a temperature gradient is based on three main soil thermal properties: the thermal conductivity (λ), the thermal capacity (C) and the thermal diffusivity (α = λ/C). The temperature variations affect the physical properties of soil, inducing changes in its thermal properties. In this study, the evolution of thermal properties of different compacted soils exposed to cyclic temperature variations were investigated through laboratory tests. The results showed that at 20 °C, the thermal conductivity of the compacted soils increased on the dry side of the compaction curve until it reached a maximum near the optimum water content. Variation of λ in a temperature range of 1–20 °C was not shown, but a slight increase of λ was measured in the range of 20–40 °C, which was clearly confirmed in the range of 40–70 °C. The application of cyclic temperature variations to the samples showed partially reversible evolution of thermal conductivity and totally reversible evolution of volumetric heat capacity.
Geosynthetic clay liners (GCLs) are used in landfill liner applications and there is a need for a better control of the properties of the bentonite in the GCL received on site, particularly in the European context where a wide variety of bentonites can be encountered. This paper presents the results of a project aimed at a rapid identification of the nature of the bentonite in a given GCL. The interaction between the bentonite and the fluid was increased by producing dispersions then testing its structure within a few hours with filter press tests and flow curves. The results of those tests were compared with swell index tests, electrical conductivity values and oedopermeametric tests. Eight GCLs were studied. Two of these GCLs contained natural calcium bentonites; they presented poor swelling properties and high permittivities. The dispersions had a low viscosity and their filtration under pressure led to large amounts of filtrate. A further two GCLs contained natural sodium bentonites and the remaining four contained sodium-activated calcium bentonites. Their permittivities, swell indices and filtrate masses were similar; however, their rheometrical behaviours were different due to a difference in the values of electrical conductivity. Thus it seems that electrical conductivity measurements and rheological tests can provide a good and fast way of identifying the nature of the bentonite contained in GCLs.