Dendritic spine generation and elimination play an important role in learning and memory, the dynamics of which have been examined within the neocortex in vivo. Spine turnover has also been detected in the absence of specific learning tasks, and is frequently exaggerated in animal models of autistic spectrum disorder (ASD). The present study aimed to examine whether the baseline rate of spine turnover was activity-dependent. This was achieved using a microfluidic brain interface and open-dura surgery, with the goal of abolishing neuronal Ca2+ signaling in the visual cortex of wild-type mice and rodent models of fragile X syndrome (Fmr1 knockout [KO]). In wild-type and Fmr1 KO mice, the majority of baseline turnover was found to be activity-independent. Accordingly, the application of matrix metalloproteinase-9 inhibitors selectively restored the abnormal spine dynamics observed in Fmr1 KO mice, without affecting the intrinsic dynamics of spine turnover in wild-type mice. Such findings indicate that the baseline turnover of dendritic spines is mediated by activity-independent intrinsic dynamics. Furthermore, these results suggest that the targeting of abnormal intrinsic dynamics might pose a novel therapy for ASD.
25 August 2015 in IEEE Transactions on Electron Devices
In this paper, we propose and demonstrate an implantable CMOS image sensor with self-resetting pixels. The self-resetting function is implemented using a four-transistor Schmitt trigger inverter. The pixel has no counter for the number of self-resets, because the application does not require radiometric (linear) response. The pixel is fabricated using the 0.35-μm 2-poly 4-metal standard CMOS technology, which results in the pixel size of 15 μm×15 μm and a fill factor of 31%. The effective peak signal-to-noise ratio is >59 dB. An image sensor prototype comprising a 60 × 134 pixel array is designed, and an implantable device is fabricated. As an example imaging experiment, we demonstrate blood-flow imaging of a rat-brain surface using the sensor. Intensity-change images are successfully obtained from the self-resetting pixel outputs with the image processing.
The high-resolution imaging of neural cells in vivo has brought about great progress in neuroscience research. Here, we report a novel experimental platform, where the intact brain of a living mouse can be studied with the aid of a surgically implanted micro-optical fluidic device; acting as an interface between neurons and the outer world. The newly developed device provides the functions required for the long-term and high-resolution observation of the fine structures of neurons by two-photon laser scanning microscopy and the microfluidic delivery of chemicals or drugs directly into the brain. A proof-of-concept experiment of single-synapse stimulation by two-photon uncaging of caged glutamate and observation of dendritic spine shrinkage over subsequent days demonstrated a promising use for the present technology.
28 January 2022 in IEEE Transactions on Electron Devices
In this article, We demonstrated an image sensor for detecting changes in polarization with high sensitivity. For this purpose, we constructed an optical system with a two-layer structure, comprising an external polarizer and polarizers on a pixel array. An external polarizer is used to enhance the polarization rotation while reducing the intensity to avoid pixel saturation of the image sensor. Using a two-layer structure, the two polarizers can be arranged under optimal conditions and the image sensor can achieve high polarization-change detection performance. We fabricated the polarization image sensor using a 0.35- $\mu \text{m}$ CMOS process and, by averaging 50 ${\times }\,\,50$ pixels and 96 frames, achieved a polarization rotation detection limit of 5.2 ${\times }\,\,10^{-4^{\circ}} $ at a wavelength of 625 nm. We also demonstrated the applicability of electric-field distribution imaging using an electrooptic crystal (ZnTe) for weak-polarization-change distribution measurements.
11 March 2016 in Japanese Journal of Applied Physics
A self-reset pixel of 15 × 15 µm2 with high signal-to-noise ratio (effective peak SNR ≃64 dB) for an implantable image sensor has been developed for intrinsic signal detection arising from hemodynamic responses in a living mouse brain. For detecting local conversion between oxyhemoglobin (HbO) and deoxyhemoglobin (HbR) in brain tissues, an implantable imaging device was fabricated with our newly designed self-reset image sensor and orange light-emitting diodes (LEDs; λ = 605 nm). We demonstrated imaging of hemodynamic responses in the sensory cortical area accompanied by forelimb stimulation of a living mouse. The implantable imaging device for intrinsic signal detection is expected to be a powerful tool to measure brain activities in living animals used in behavioral analysis.
The application of the fluorescence imaging method to living animals, together with the use of genetically engineered animals and synthesized photo-responsive compounds, is a powerful method for investigating brain functions. Here, we report a fluorescence imaging method for the brain surface and deep brain tissue that uses compact and mass-producible semiconductor imaging devices based on complementary metal-oxide semiconductor (CMOS) technology. An image sensor chip was designed to be inserted into brain tissue, and its size was 1500 × 450 μm. Sample illumination is also a key issue for intravital fluorescence imaging. Hence, for the uniform illumination of the imaging area, we propose a new method involving the epi-illumination of living biological tissues, and we performed investigations using optical simulations and experimental evaluation.