In this article, We demonstrated an image sensor for detecting changes in polarization with high sensitivity. For this purpose, we constructed an optical system with a two-layer structure, comprising an external polarizer and polarizers on a pixel array. An external polarizer is used to enhance the polarization rotation while reducing the intensity to avoid pixel saturation of the image sensor. Using a two-layer structure, the two polarizers can be arranged under optimal conditions and the image sensor can achieve high polarization-change detection performance. We fabricated the polarization image sensor using a 0.35- $\mu \text{m}$ CMOS process and, by averaging 50 ${\times }\,\,50$ pixels and 96 frames, achieved a polarization rotation detection limit of 5.2 ${\times }\,\,10^{-4^{\circ}} $ at a wavelength of 625 nm. We also demonstrated the applicability of electric-field distribution imaging using an electrooptic crystal (ZnTe) for weak-polarization-change distribution measurements.
In this research, we combined our ultralight micro-imaging device for calcium imaging with microdialysis to simultaneously visualize neural activity in the dorsal raphe nucleus (DRN) and measure serotonin release in the central nucleus of the amygdala (CeA) and the anterior cingulate cortex (ACC). Using this platform, we observed brain activity following nociception induced by formalin injection in the mouse’s hind paw. Our device showed that DRN fluorescence intensity increased after formalin injection, and the increase was highly correlated with the elevation in serotonin release in both the CeA and ACC. The increase in calcium fluorescence intensity occurred during the acute and inflammatory phases, which suggests the biphasic response of nociceptive pain. Furthermore, we found that the increase in fluorescence intensity was positively correlated with mouse licking behavior. Lastly, we compared the laterality of pain stimulation and found that DRN fluorescence activity was higher for contralateral stimulation. Microdialysis showed that CeA serotonin concentration increased only after contralateral stimulation, while ACC serotonin release responded bilaterally. In conclusion, our study not only revealed the inter-regional serotonergic connection among the DRN, the CeA, and the ACC, but also demonstrated that our device is feasible for multi-site implantation in conjunction with a microdialysis system, allowing the simultaneous multi-modal observation of different regions in the brain.
Dopamine (DA) is the most important neurotransmitter involved in motor control. Abnormalities in neurotransmitter levels may indicate brain disorders, such as Parkinson’s disease and depression. Herein, electrochemical sensors containing metal oxide nanoparticles were fabricated for detecting DA. Specifically, iron oxide nanoparticles were applied onto a flexible polyimide substrate to obtain a flexible microelectrode and their DA detection performance was evaluated in vitro and in vivo. The electrochemical performance of the fabricated sensor was evaluated via fast-scan cyclic voltammetry conducted in a DA solution at concentrations between 0 and 50 nM. The peak current corresponding to the oxidation reaction of the Fe2O3-modified microelectrode for DA was observed at an applied potential of 0.49 V. The modified microelectrode exhibited a DA response with a high sensitivity of 34.14 nA/μm2 nM and a low limit of detection of 8.76 nM. In vivo experiments were performed using a freely moving mouse. Notably, 15 min after nicotine injection, the current increased considerably. The peak current corresponded to a 10 nM concentration in the calibration curve. The co-detection of DA and serotonin was also analyzed. The results showed that only the oxidation peak of DA appeared upon applying a triangular voltage waveform. Therefore, the proposed detector is capable of overcoming the drawbacks associated with conventional detectors and can be integrated with other implantable devices.
10 February 2022 in Japanese Journal of Applied Physics
In this study, a dual-band hybrid filter that achieves high excitation light rejection performance in a lensless imaging system was fabricated and incorporated into an imaging device. The hybrid filter consisted of interference and absorption filters, and a fiber optic plate (FOP). The interference filters were attached to both sides of the FOP, which was placed on top of the absorption filter to suppress the decrease in spatial resolution. In addition, the lamination order was optimized to achieve a high fluorescence observation performance. The fabricated hybrid filter was mounted on an image sensor and had the ability to indicate the green and red fluorescence components.
Significance: Intrinsic optical signals (IOS) generated in the cortical tissue as a result of various interacting metabolic processes are used extensively to elucidate the underlying mechanisms that govern neurovascular coupling. However, current IOS measurements still often rely on bulky, tabletop imaging systems, and there remains a dearth of studies in freely moving subjects. Lightweight, miniature head-mounted imaging devices provide unique opportunities for investigating cortical dynamics in small animals under a variety of naturalistic behavioral settings. Aim: The aim of this work was to monitor IOS in the somatosensory cortex of wild-type mice by developing a lightweight, biocompatible imaging device that readily lends itself to animal experiments in freely moving conditions. Approach: Herein we describe a method for realizing long-term IOS imaging in mice using a 0.54-g, compact, CMOS-based, head-mounted imager. The two-part module, consisting of a tethered sensor plate and a base plate, allows facile assembly prior to imaging sessions and disassembly when the sensor is not in use. LEDs integrated into the device were chosen to illuminate the cortical mantle at two different wavelengths in the visible regime (λcenter: 535 and 625 nm) for monitoring volume- and oxygenation state-dependent changes in the IOS, respectively. To test whether the system can detect robust cortical responses, we recorded sensory-evoked IOS from mechanical stimulation of the hindlimbs (HL) of anesthetized mice in both acute and long-term implantation conditions. Results: Cortical IOS recordings in the primary somatosensory cortex hindlimb receptive field (S1HL) of anesthetized mice under green and red LED illumination revealed robust, multiphasic profiles that were time-locked to the mechanical stimulation of the contralateral plantar hindpaw. Similar intrinsic signal profiles observed in S1HL at 40 days postimplantation demonstrated the viability of the approach for long-term imaging. Immunohistochemical analysis showed that the brain tissue did not exhibit appreciable immune response due to the device implantation and operation. A proof-of-principle imaging session in a freely behaving mouse showed minimal locomotor impediment for the animal and also enabled estimation of blood flow speed. Conclusions: We demonstrate the utility of a miniature cortical imaging device for monitoring IOS and related hemodynamic processes in both anesthetized and freely moving mice, cueing potential for applications to some neuroscientific studies of sensation and naturalistic behavior.
Long-term operational stability and high-efficiency neuron stimulation are key to the development of retinal prostheses. In this research, a retinal device with a chemically inert and flexible substrate is introduced, which satisfies these requirements. We have developed a honeycomb-type retinal device that has a high-performance electrode for suprachoroidal transretinal stimulation. The device structure, in which conjunctional bioceramic substrates are embedded with large numbers of stimulating electrodes, provides high-resolution electrical stimulation. The custom CMOS microchip precisely controls the stimulation delivery of the electrodes to initiate artificial vision, offering a partial remedy for retinal ophthalmic diseases. The CMOS chip design was optimized to drastically reduce the number of input wirings. A high-performance stimulating electrode based on iridium oxide was fabricated using a unique solution process called chemical bath deposition (CBD). The honeycomb-type retinal device, equipped with CBD-derived iridium oxide electrodes, was used to evaluate the electrodes’ and device’s performances in vitro.