In a small dc-link drive system, the LC resonance is a typical phenomenon caused by the negative inverter admittance related to the constant power load, which is considered an instability problem that needs to be resolved well. In this article, a novel dc-link voltage feedback active damping control method is proposed to improve system stability. First, the feedback control loop with time delay is established. Based on the inverter admittance, the feedback gain is designed to handle various operating conditions properly. Meanwhile, the inverter equivalent admittance can be changed into positive to improve the system stability. Then, the oversampling method is proposed to reduce the digital control delay time and improve the damping current precision. Therefore, the system damping performance is further enhanced. Finally, the damping current modification is applied, in which the damping current is modified to negative in the motor regenerative braking mode to improve the grid power factor. Compared with the conventional active damping method, the power factor is increased to 0.989 and the grid current harmonics are reduced to satisfy the requirements of EN61000-3-2. The effectiveness of the proposed active damping method is also verified by the experimental results.
In traditional motor drive system, large volume electrolytic capacitors are utilized to buffer energy and stabilize the dc-link voltage. However, these capacitors affect the reliability of the drives and narrow the conduction angle of diode-rectifier. As a result, the grid side current is distorted and the power factor is deteriorated. In order to settle these issues, small dc-link capacitors can replace the electrolytic capacitors. In this paper, a motor torque control method with dc-link voltage feed-forward compensation for an interior permanent magnet synchronous motor (IPMSM) drive system is proposed. Hence, an integration multi-resonant (I-MR) controller is established to regulate the motor torque to obtain high input power factor and low grid current harmonics. In addition, a voltage feed-forward compensation is used to diminish the error of motor torque control. The effectiveness of the proposed method is verified through simulation and experiments. Results indicate that the input power factor can reach about 99.4% and the grid current harmonics are considerably lower than the requirement of EN-61000-3-2 standard.
In this paper, an improved sensorless vector control method for an interior permanent magnet synchronous motor (IPMSM) drive with small DC-link capacitors is proposed. First, a fast sliding-mode observer was applied, to enlarge the observer bandwidth. Then, an improved estimator based on a proportional integral resonant controller was designed for the estimate speed shaping, which means the actual speed can be tracked. This not only reduces the position estimate error, but also enhances the grid power factor and suppresses the input current harmonics. Simulation and experiments were conducted on a sensorless IPMSM drive system with a small film capacitor. The effectiveness of the proposed estimation method was verified by the simulation and experimental results. The estimated error was reduced and the grid current harmonics satisfy the requirements of EN61000-3-2.
20 September 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Film capacitors are used in power electronic converters due to their higher reliability compared to aluminum electrolytic capacitors. Humidity is one of the critical factors affecting the aging of film capacitors. However, the existing methodologies for lifetime estimation of film capacitors rarely consider humidity. Besides, sometimes it is hard to obtain a large amount of data in the accelerated aging test of the device. To solve these problems, this paper proposes a lifetime estimation methodology that requires less data and testing time. In the proposed methodology, humidity dummy variables are introduced into the degradation model based on the multivariate linear regression (MLR) algorithm. The impact of introduced dummy variables with different structures on the degradation model is studied and the effect of the proposed lifetime estimation method is verified. The results show that the proposed scheme achieves a comparable performance and can be valid in reality.
With large input line inductance and low dc‐link capacitance, the small dc‐link drive system shows an instability problem, which is mainly caused by LC resonance between the line side inductor and the dc‐link film capacitor. This paper proposes a grid current feedback active damping control method to improve system stability and suppress the LC resonance. The feedback variables are analyzed, and the detected grid current is selected. Thus, the damping current is consistent with the LC resonance components in grid current, which benefits the drive system power factor and grid current quality. Furthermore, the grid current feedback control loop has been established, and the feedback gain is designed based on system parameters that can be adjusted to fit different systems. The stability margin and robustness of the drive system to the changes in line inductance and dc‐link capacitance are improved. Compared with the conventional voltage‐based damping method, the power factor is increased to 0.984 and the grid current harmonics are reduced to satisfy the requirements of EN61000‐3‐2. The effectiveness of the proposed active damping method is verified by the experimental results.
20 September 2018 in Journal of Advanced Computational Intelligence and Intelligent Informatics
Title: Stability Regions of Nonlinear LCL-Filtered Converter with Converter-Current-Feedback Control Without Damping | Keywords: converter, nonlinear LCL-filtered model, stable boundaries, undamping | Author: Qingyi Wang, Xuefen Wang, Min Ding, Quan Yin, and Haichun Li