LUCA BROMBAL

Dr. LUCA BROMBAL

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
RLRenata Longo
Renata Longo
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
UBUbaldo Bottigli
Ubaldo Bottigli
LBLUCA BROMBAL
LUCA BROMBAL
GTGiuliana Tromba
Giuliana Tromba

1 December 2018 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
DDDiego Dreossi
Diego Dreossi
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
RLRenata Longo
Renata Longo
X-ray phase imaging has the potential to dramatically improve soft tissue contrast sensitivity, which is a crucial requirement in many diagnostic applications such as breast imaging. In this context, a program devoted to perform in vivo phase-contrast synchrotron radiation breast computed tomography is ongoing at the Elettra facility (Trieste, Italy). The used phase-contrast technique is the propagation-based configuration, which requires a spatially coherent source and a sufficient object-to-detector distance. In this work the effect of this distance on image quality is quantitatively investigated scanning a large breast surgical specimen at three object-to-detector distances (1.6, 3, 9 m) and comparing the images both before and after applying the phase-retrieval procedure. The sample is imaged at 30 keV with a pixel pitch CdTe single-photon-counting detector, positioned at a fixed distance of 31.6 m from the source. The detector fluence is kept constant for all acquisitions. The study shows that, at the largest distance, a 20-fold SNR increase can be obtained by applying the phase-retrieval procedure. Moreover, it is shown that, for phase-retrieved images, changing the object-to-detector distance does not affect spatial resolution while boosting SNR (four-fold increase going from the shortest to the largest distance). The experimental results are supported by a theoretical model proposed by other authors, whose salient results are presented in this paper.

28 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
FAFulvia Arfelli
Fulvia Arfelli
PDPasquale Delogu
Pasquale Delogu
Sandro DonatoSandro Donato
Sandro Donato
GMGiovanni Mettivier
Giovanni Mettivier
CFChristian Fedon
Christian Fedon
In this study we compared the image quality of a synchrotron radiation (SR) breast computed tomography (BCT) system with a clinical BCT in terms of contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), noise power spectrum (NPS), spatial resolution and detail visibility. A breast phantom consisting of several slabs of breast-adipose equivalent material with different embedded targets (i.e., masses, fibers and calcifications) was used. Phantom images were acquired using a dedicated BCT system installed at the Radboud University Medical Center (Nijmegen, The Netherlands) and the SR BCT system at the SYRMEP beamline of Elettra SR facility (Trieste, Italy) based on a photon-counting detector. Images with the SR setup were acquired mimicking the clinical BCT conditions (i.e., energy of 30 keV and radiation dose of 6.5 mGy). Images were reconstructed with an isotropic cubic voxel of 273 µm for the clinical BCT, while for the SR setup two phase-retrieval (PhR) kernels (referred to as “smooth” and “sharp”) were alternatively applied to each projection before tomographic reconstruction, with voxel size of 57 × 57 × 50 µm3. The CNR for the clinical BCT system can be up to 2-times higher than SR system, while the SNR can be 3-times lower than SR system, when the smooth PhR is used. The peak frequency of the NPS for the SR BCT is 2 to 4-times higher (0.9 mm−1 and 1.4 mm−1 with smooth and sharp PhR, respectively) than the clinical BCT (0.4 mm−1). The spatial resolution (MTF10%) was estimated to be 1.3 lp/mm for the clinical BCT, and 5.0 lp/mm and 6.7 lp/mm for the SR BCT with the smooth and sharp PhR, respectively. The smallest fiber visible in the SR BCT has a diameter of 0.15 mm, while for the clinical BCT is 0.41 mm. Calcification clusters with diameter of 0.13 mm are visible in the SR BCT, while the smallest diameter for the clinical BCT is 0.29 mm. As expected, the image quality of the SR BCT outperforms the clinical BCT system, providing images with higher spatial resolution and SNR, and with finer granularity. Nevertheless, this study assesses the image quality gap quantitatively, giving indications on the benefits associated with SR BCT and providing a benchmarking basis for its clinical implementation. In addition, SR-based studies can provide a gold-standard in terms of achievable image quality, constituting an upper-limit to the potential clinical development of a given technique.

1 June 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
Sandro DonatoSandro Donato
Sandro Donato
Francesco BrunFrancesco Brun
Francesco Brun
PDPasquale Delogu
Pasquale Delogu
VFViviana Fanti
Viviana Fanti
BGBruno Golosio
Bruno Golosio

1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
APAnna Piai
Anna Piai
ACAdriano Contillo
Adriano Contillo
FAFulvia Arfelli
Fulvia Arfelli
DBDeborah Bonazza
Deborah Bonazza
LBLUCA BROMBAL
LUCA BROMBAL
RLRenata Longo
Renata Longo
A quantitative characterization of the soft tissues composing the human breast is achieved by means of a monochromatic CT phase-contrast imaging system, through accurate measurements of their attenuation coefficients within the energy range of interest for breast CT clinical examinations. Quantitative measurements of linear attenuation coefficients are performed on tomographic reconstructions of surgical samples, using monochromatic x-ray beams from a synchrotron source and a free space propagation setup. An online calibration is performed on the obtained reconstructions, in order to reassess the validity of the standard calibration procedure of the CT scanner. Three types of healthy tissues (adipose, glandular, and skin) and malignant tumors, when present, are considered from each sample. The measured attenuation coefficients are in very good agreement with the outcomes of similar studies available in the literature, although they span an energy range that was mostly neglected in the previous studies. No globally significant differences are observed between healthy and malignant dense tissues, although the number of considered samples does not appear sufficient to address the issue of a quantitative differentiation of tumors. The study assesses the viability of the proposed methodology for the measurement of linear attenuation coefficients, and provides a denser sampling of attenuation data in the energy range useful to breast CT.

4 March 2019 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
LBLUCA BROMBAL
LUCA BROMBAL
GKG. Kallon
G. Kallon
JJJ. Jiang
J. Jiang
SSS. Savvidis
S. Savvidis
PCPaolo De Coppi
Paolo De Coppi
Marco EndrizziMarco Endrizzi
Marco Endrizzi
We present an experimental setup for monochromatic propagation-based x-ray phase-contrast imaging based on a conventional rotating-copper-anode source, capable of an integrated flux up to 108 photons/s at 8 keV. In our study, the system is characterized in terms of spatial coherence, resolution, contrast sensitivity, and stability. Its quantitativeness is demonstrated by comparing theoretical predictions with experimental data on simple wire phantoms both in planar and computerized-tomography-scan geometries. Application to two biological samples of medical interest shows the potential for bioimaging on the millimeter scale with spatial resolution of the order of 10 μm and contrast resolution below 1%. All the scans are performed within laboratory-compatible exposure times, from 10 min to a few hours, and trade-offs between scan time and image quality are discussed.