Background In risk assessment, genotoxicity is a key factor to determine the safety for the consumer. Most in vitro genotoxicity assays were developed for the assessment of pure substances. However, in recent years more attention has been given to complex mixtures, where usually low amounts of a substance are present. For high-throughput screening, a toxicologically sensitive assay should be used, covering a broad range of genotoxic substances and detecting them at low concentrations. HepG2 cells have been recommended as one of the prime candidates for genotoxicity testing, as they are p53 competent, less prone towards cytotoxic effects and tend to have some metabolic activity. Methods A HepG2 liver cell line was characterized for its suitability for genotoxicity assessment. For this, a luciferase based reporter gene assay revolving around the p53 pathway was validated for the analysis of pure substances and of complex mixtures. Further, the cell’s capability to detect genotoxins correctly with and without an exogenous metabolizing system, namely rat liver S9, was assessed. Results The assay proved to have a high toxicological sensitivity (87.5%) and specificity (94%). Further, the endogenous metabolizing system of the HepG2 cells was able to detect some genotoxins, which are known to depend on an enzymatic system. When complex mixtures were added this did not lead to any adverse effects concerning the assays performance and cytotoxicity was not an issue. Discussion The HepGentox proved to have a high toxicological sensitivity and specificity for the tested substances, with similar or even lower lowest effective concentration (LEC) values, compared to other regulatory mammalian assays. This combines some important aspects in one test system, while also being less time and material consuming and covering several genotoxicity endpoints. As the assay performs well with and without an exogenous metabolizing system, no animal liver fractions have to be used, which application is discussed controversially and is considered to be expensive and laborious in sample testing. Because of this, the HepGentox is suitable for a cost-efficient first screening approach to obtain important information with human cells for further approaches, with a relatively fast and easy method. Therefore, the HepGentox is a promising assay to detect genotoxic substances correctly in complex mixtures even at low concentrations, with the potential for a high throughput application. In a nutshell, as part of an in vitro bioassay test battery, this assay could provide valuable information for complex mixtures.
Elisabeth Pinter; Christina Friedl; Alexandra Irnesberger; Thomas Czerny; Tina Piwonka; Alfonso Peñarroya; Manfred Tacker; Elisabeth Riegel. HepGentox: a novel promising HepG2 reportergene-assay for the detection of genotoxic substances in complex mixtures. PeerJ 2021, 9, e11883 .
AMA StyleElisabeth Pinter, Christina Friedl, Alexandra Irnesberger, Thomas Czerny, Tina Piwonka, Alfonso Peñarroya, Manfred Tacker, Elisabeth Riegel. HepGentox: a novel promising HepG2 reportergene-assay for the detection of genotoxic substances in complex mixtures. PeerJ. 2021; 9 ():e11883.
Chicago/Turabian StyleElisabeth Pinter; Christina Friedl; Alexandra Irnesberger; Thomas Czerny; Tina Piwonka; Alfonso Peñarroya; Manfred Tacker; Elisabeth Riegel. 2021. "HepGentox: a novel promising HepG2 reportergene-assay for the detection of genotoxic substances in complex mixtures." PeerJ 9, no. : e11883.
With the European Green Deal, the importance of recycled products and materials has increased. Specifically, for PET bottles, a high content of recycled material (rPET) is demanded by the industry and consumers. This study was carried out in a lab environment replicating real-life industrial processes, to investigate the possible impacts on rPET quality over eleven recycling loops, aiming to use high amounts of rPET repetitively. A cycle included extrusion, solid state polycondensation (SSP), a second extrusion to simulate bottle production, hot wash and a drying step. 75% rPET and 25% virgin PET were extruded in eleven cycles to simulate a recycling and production process. Samples underwent chemical, physical and biological analysis. The quality of the rPET material was not adversely affected. Parameters such as coloring, intrinsic viscosity, concentration of critical chemicals and presence of mutagenic contaminants could be positively assessed. The quality of the produced material was likely influenced by the input material’s high standard. A closed loop PET bottle recycling process using an rPET content of up to 75% was possible when following the proposed process, indicating that this level of recycled content can be maintained indefinitely without compromising quality.
Elisabeth Pinter; Frank Welle; Elisa Mayrhofer; Andreas Pechhacker; Lukas Motloch; Vera Lahme; Andy Grant; Manfred Tacker. Circularity Study on PET Bottle-To-Bottle Recycling. Sustainability 2021, 13, 7370 .
AMA StyleElisabeth Pinter, Frank Welle, Elisa Mayrhofer, Andreas Pechhacker, Lukas Motloch, Vera Lahme, Andy Grant, Manfred Tacker. Circularity Study on PET Bottle-To-Bottle Recycling. Sustainability. 2021; 13 (13):7370.
Chicago/Turabian StyleElisabeth Pinter; Frank Welle; Elisa Mayrhofer; Andreas Pechhacker; Lukas Motloch; Vera Lahme; Andy Grant; Manfred Tacker. 2021. "Circularity Study on PET Bottle-To-Bottle Recycling." Sustainability 13, no. 13: 7370.
The Ames assay is the standard assay for identifying DNA-reactive genotoxic substances. Multiple formats are available and the correct choice of an assay protocol is essential for achieving optimal performance, including fit for purpose detection limits and required screening capacity. In the present study, a comparison of those parameters between two commonly used formats, the standard pre-incubation Ames test and the liquid-based Ames MPF™, was performed. For that purpose, twenty-one substances with various modes of action were chosen and tested for their lowest effect concentrations (LEC) with both tests. In addition, two sources of rat liver homogenate S9 fraction, Aroclor 1254-induced and phenobarbital/β-naphthoflavone induced, were compared in the Ames MPF™. Overall, the standard pre-incubation Ames and the Ames MPF™ assay showed high concordance (>90%) for mutagenic vs. non-mutagenic compound classification. The LEC values of the Ames MPF™ format were lower for 17 of the 21 of the selected test substances. The S9 source had no impact on the test results. This leads to the conclusion that the liquid-based Ames MPF™ assay format provides screening advantages when low concentrations are relevant, such as in the testing of complex mixtures.
Bernhard Rainer; Elisabeth Pinter; Lukas Prielinger; Chiara Coppola; Maricel Marin-Kuan; Benoit Schilter; Silvia Apprich; Manfred Tacker. Direct Comparison of the Lowest Effect Concentrations of Mutagenic Reference Substances in Two Ames Test Formats. Toxics 2021, 9, 152 .
AMA StyleBernhard Rainer, Elisabeth Pinter, Lukas Prielinger, Chiara Coppola, Maricel Marin-Kuan, Benoit Schilter, Silvia Apprich, Manfred Tacker. Direct Comparison of the Lowest Effect Concentrations of Mutagenic Reference Substances in Two Ames Test Formats. Toxics. 2021; 9 (7):152.
Chicago/Turabian StyleBernhard Rainer; Elisabeth Pinter; Lukas Prielinger; Chiara Coppola; Maricel Marin-Kuan; Benoit Schilter; Silvia Apprich; Manfred Tacker. 2021. "Direct Comparison of the Lowest Effect Concentrations of Mutagenic Reference Substances in Two Ames Test Formats." Toxics 9, no. 7: 152.
Background: Non-targeted screening of food contact materials (FCM) for non-intentionally added substances (NIAS) reveals a great number of unknown and unidentified substances present at low concentrations. In the absence of toxicological data, the application of the threshold of toxicological concern (TTC) or of EU Regulation 10/2011 requires methods able to fulfill safety threshold criteria. In this review, mammalian in vitro genotoxicity assays are analyzed for their ability to detect DNA-damaging substances at limits of biological detection (LOBD) corresponding to the appropriate safety thresholds. Results: The ability of the assays to detect genotoxic effects varies greatly between substance classes. Especially for direct-acting mutagens, the assays lacked the ability to detect most DNA reactive substances below the threshold of 10 ppb, making them unsuitable to pick up potential genotoxicants present in FCM migrates. However, suitability for the detection of chromosomal damage or investigation of other modes of action makes them a complementary tool as part of a standard test battery aimed at giving additional information to ensure safety. Conclusion: improvements are necessary to comply with regulatory thresholds to consider mammalian genotoxicity in vitro assays to assess FCM safety.
Elisabeth Pinter; Bernhard Rainer; Thomas Czerny; Elisabeth Riegel; Benoît Schilter; Maricel Marin-Kuan; Manfred Tacker. Evaluation of the Suitability of Mammalian In Vitro Assays to Assess the Genotoxic Potential of Food Contact Materials. Foods 2020, 9, 237 .
AMA StyleElisabeth Pinter, Bernhard Rainer, Thomas Czerny, Elisabeth Riegel, Benoît Schilter, Maricel Marin-Kuan, Manfred Tacker. Evaluation of the Suitability of Mammalian In Vitro Assays to Assess the Genotoxic Potential of Food Contact Materials. Foods. 2020; 9 (2):237.
Chicago/Turabian StyleElisabeth Pinter; Bernhard Rainer; Thomas Czerny; Elisabeth Riegel; Benoît Schilter; Maricel Marin-Kuan; Manfred Tacker. 2020. "Evaluation of the Suitability of Mammalian In Vitro Assays to Assess the Genotoxic Potential of Food Contact Materials." Foods 9, no. 2: 237.