Attaining dimensional accuracy in CNC-machined parts is essential for high-precision manufacturing, especially when working with materials that exhibit varying mechanical and thermal characteristics. This research provides a thorough experimental comparison of manual and automated metrological systems, specifically the Digital Vernier Caliper (DVC) and Coordinate Measuring Machine (CMM), as applied to five different engineering alloys through five progressively machined axial zones. The study assesses absolute error, relative error, standard deviation, and measurement repeatability, factoring in material hardness, thermal conductivity, and surface changes due to machining. The results indicate that DVC performance is significantly affected by operator input and surface irregularities, with standard deviations reaching 0.03333 mm for Bronze C51000 and relative errors surpassing 1.02% in the initial zones. Although DVC occasionally showed lower absolute errors (e.g., 0.206 mm for Aluminum 6061), these advantages were countered by greater uncertainty and poor repeatability. In comparison, CMM demonstrated enhanced precision and consistency across all materials, with standard deviations below 0.0035 mm and relative errors being neatly within the 0.005–0.015% range, even with challenging alloys like Stainless Steel 304. Furthermore, a Principal Component Analysis (PCA) was conducted to identify underlying measurement–property relationships. The PCA highlighted clear groupings based on sensitivity to error in manual versus automated methods, facilitating predictive classification of materials according to their metrological reliability. The introduction of multivariate modeling also establishes a new framework for intelligent metrology selection based on material characteristics and machining responses. These results advocate for using CMM in applications requiring precise tolerances in the aerospace, biomedical, and high-end tooling sectors, while suggesting that DVC can serve as an auxiliary tool for less critical evaluations. This study provides practical recommendations for aligning measurement techniques with Industry 4.0’s needs for accuracy, reliability, and data-driven quality assurance.
The mechanical damage variable, as well as the thermal and mechanical relaxation times, plays essential roles in the thermal quality factor of the resonators, where controls energy damping through the coupling of mechanical and thermal behavior. In this article, we developed a mathematical model in which a static-pre-stress and mechanical damage variable in the context of a two-temperature viscothermoelasticity of silicon resonator has been considered. The effects of static-pre-stress, thermal relaxation time, mechanical relaxation time, mechanical damage variable, isothermal frequency, and length-scale on the quality factor have been discussed in the context of a one-temperature and two-temperature models. The model predicts that significant improvement in terms of quality factors is possible by tuning the static-pre-stress, isothermal frequency, and length-scale of the resonator. Moreover, the thermal and mechanical relaxation times and the mechanical damage variable have impacts on the thermal quality factor.
Accurate measurement uncertainty quantification and its propagation are critical for dimensional compliance in precision manufacturing. This study presents a novel framework that examines the evolution of measurement error along the axial length of CNC-turned components, focusing on spatial and material-specific factors. A systematic experimental comparison was conducted between a manual Digital Vernier Caliper (DVC) and an automated Coordinate Measuring Machine (CMM) using five engineering materials: Aluminum Alloy 6061, Brass C26000, Bronze C51000, Carbon Steel 1020 Annealed, and Stainless Steel 304 Annealed. Dimensional measurements were taken from five consecutive machining zones to capture localized metrological behaviors. The results indicated that the CMM consistently achieved lower expanded uncertainty (as low as 0.00166 mm) and minimal propagated uncertainties (≤0.0038 mm), regardless of material hardness or cutting position. In contrast, the DVC demonstrated significantly higher uncertainty (up to 0.03333 mm) and propagated errors exceeding 0.035 mm, particularly in harder materials and unsupported zones affected by surface degradation and fixture variability. Root-sum-square (RSS) modeling confirmed that manual measurements are more prone to operator-induced error amplification. While the DVC sometimes recorded lower absolute errors, its substantial uncertainty margins hampered measurement reliability. To statistically validate these findings, a two-way ANOVA was performed, confirming that both the measurement system and machining zone significantly impacted uncertainty, as well as their interaction. These results emphasize the importance of material-informed and zone-sensitive metrology, highlighting the advantages of automated systems in sustaining measurement repeatability and dimensional stability in high-precision applications.