Bandar Alsehli

Dr. Bandar Alsehli

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2024 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
Mahmoud El-MaghrabeyMahmoud El-Maghrabey
Mahmoud El-Maghrabey
MHMohamed A. El HAmd
Mohamed A. El HAmd
LALateefa A. Al-Khateeb
Lateefa A. Al-Khateeb
GMGalal Magdy
Galal Magdy
WMWael A. Mahdi
Wael A. Mahdi
RERania N. El-Shaheny
Rania N. El-Shaheny

27 September 2024 in Journal of Photochemistry and Photobiology A: Chemistry
Verified
Journal Article
Closed access
Nafees AhmadNafees Ahmad
Nafees Ahmad
BABandar Alsehli
Bandar Alsehli
AMAsif Mahmood
Asif Mahmood
YZYingping Zou
Yingping Zou

12 February 2025 in BioNanoScience
Verified
Journal Article
Closed access
PDF file
BABandar Alsehli
Bandar Alsehli
Mostafa Farouk Al-HakkaniMostafa Farouk Al-Hakkani
Mostafa Farouk Al-Hakkani
AAAbdullah H. Alluhayb
Abdullah H. Alluhayb
SSSayed M. Saleh
Sayed M. Saleh
HMHassan Mohamed
Hassan Mohamed
MHMohammad H. A. Hassan
Mohammad H. A. Hassan

1 January 2025 in Reviews in Analytical Chemistry
Verified
Journal Article
Open access
PDF file
TATahani Yousef Alanazi
Tahani Yousef Alanazi
SMSamar M. Mahgoub
Samar M. Mahgoub
Hoda A. AhmedHoda A. Ahmed
Hoda A. Ahmed
MAManal Abdulmohsen Almalki
Manal Abdulmohsen Almalki
BABandar Alsehli
Bandar Alsehli
MMMahmoud Abdelfatah Mohamed
Mahmoud Abdelfatah Mohamed
Analytical chemistry research has shifted towards environmentally friendly substitutes that reduce waste and avoid hazardous substances. These efforts align with broader environmental goals and inspire sustainable and responsible science. The objective of this work is to develop and validate an analytical method and verify its greenness using specific tools, including analytical GREEnness (AGREE), analytical greenness metric for sample preparation (AGREEprep), green analytical procedure index, complex green analytical procedure index, analytical Eco-Scale, analytical method volume intensity, analytical method greenness score, and HPLC-EAT (Environmental Assessment Tool). Effective treatment of chronic cough relies heavily on adequately utilizing salbutamol (SAL) and guaifenesin (GUA) in the presence of sodium benzoate (SOB) preservative. The isocratic elution mode used the Zorbax Eclipse Plus C18 column (15 cm × 4.6 mm, 3.5 µm). It could move 1.5 mL·min −1 , hold 50 µL, have a column temperature of 30°C, and have an autosampler temperature of 5°C. It could detect UV light at 276 nm and had a mobile phase of 80:20 v/v buffer solution and acetonitrile. We have successfully established highly accurate calibration curves for the three components SAL, GUA, and SOB within the optimal range of 2–50 µg·mL −1 . The coefficient of correlation ( r ) for these curves was at an impressive 0.9999 for SAL and GUA, while it was 0.9998 for SOB. The recovery values were 100.15%, 100.47%, and 100.92% for SAL, GUA, and SOB, respectively. The selectivity and sensitivity to the ingredients were confirmed according to the International Council for Harmonisation guidelines, as no interference occurred from any of the used sample components. We implemented Six Sigma, resulting in precision and productivity.

28 October 2024 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
MHMohamed A. El HAmd
Mohamed A. El HAmd
WMWael A. Mahdi
Wael A. Mahdi
SASultan Alshehri
Sultan Alshehri
BABandar Alsehli
Bandar Alsehli
AAAhmed A. Abu-Hassan
Ahmed A. Abu-Hassan

29 March 2020 in Processes
Verified
Journal Article
Open access
PDF file
BABandar Alsehli
Bandar Alsehli
UV-Vis spectrophotometer was used to determine chlorpropham (CIPC) concentration in aqueous solution. The method was validated in term of linearity, precision and limit of detection and limit of quantitation. The correlation coefficient of standards calibration curve of (1.0–10.0 µg/mL CIPC) was R2 = 1 with a precision (RSD%, n=10) ranged from (0.87–0.53%). The limit of detection (LOD) and limit of quantitation (LOQ) based on the regression statistics of the calibration curve data of (1.0–10.0 µg/mL CIPC) were 0.04 µg/mL and 0.11 µg/mL respectively. The activated carbon adsorbent was found to be effective for the removal approximately 80% of CIPC from aqueous solution. Several isotherm models (Langmuir, Freundlich, Tempkin and Dubinin–Radushkevich) were evaluated. The maximum monolayer sorption capacity (Qm) from the Langmuir isotherm model was determined to be (44316.92 µg/g). The separation factor (RL) is 0.11 which indicates a favorable equilibrium sorption with the R2 value of 0.99, indicating that the Langmuir isotherm model fit the experimental sorption data well.