Dariusz Karkosiński

Prof. Dr. Dariusz Karkosiński

Gdańsk University of Technology, Faculty of Electrical and Control Engineering
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
SPSzymon Potrykus
Szymon Potrykus
Luis F. Leon-FernandezLuis F. Leon-Fernandez
Luis F. Leon-Fernandez
JNJanusz Nieznański
Janusz Nieznański
Dariusz KarkosińskiDariusz Karkosiński
Dariusz Karkosiński
Francisco Jesus Fernandez-MoralesFrancisco Jesus Fernandez-Morales
Francisco Jesus Fernandez-Morales
In this work, the effect of the external load on the current and power generation, as well as on the pollutant removal by microbial fuel cells (MFCs), has been studied by step-wise modifying the external load. The load changes included a direct scan, in which the external resistance was increased from 120 Ω to 3300 Ω, and a subsequent reverse scan, in which the external resistance was decreased back to 120 Ω. The reduction in the current, experienced when increasing the external resistance, was maintained even in the reverse scan when the external resistance was step-wise decreased. Regarding the power exerted, when the external resistance was increased below the value of the internal resistance, an enhancement in the power exerted was observed. However, when operating near the value of the internal resistance, a stable power exerted of about 1.6 µW was reached. These current and power responses can be explained by the change in population distribution, which shifts to a more fermentative than electrogenic culture, as was confirmed by the population analyses. Regarding the pollutant removal, the effluent chemical oxygen demand (COD) decreased when the external resistance increased up to the internal resistance value. However, the effluent COD increased when the external resistance was higher than the internal resistance. This behavior was maintained in the reverse scan, which confirmed the modification in the microbial population of the MFC.

2 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
FKFilip Kutt
Filip Kutt
KBKrzysztof Blecharz
Krzysztof Blecharz
Dariusz KarkosińskiDariusz Karkosiński
Dariusz Karkosiński
Coaxial counter-rotating propellers have been widely applied in ships and helicopters for improving the propulsion efficiency and offsetting system reactive torques. Lately, the counter-rotating concept has been introduced into the wind turbine design. Distributed wind power generation systems often require a novel approach in generator design. In this paper, prototype development of axial-flux generator with a counter-rotating field and armature is presented. The design process was composed of three main steps: analytical calculation, FEM simulation and prototype experimental measurements. The key aspect in the prototype development was the mechanical construction of two rotating components of the generator. Sturdy construction was achieved using two points of contact between both rotors via the placement of the bearing between the inner and outer rotor. The experimental analysis of the prototype generator has been conducted in the laboratory at the dynamometer test stand equipped with a torque sensor. The general premise for the development of such a machine was an investigation into the possibility of developing a dual rotor wind turbine. The proposed solution had to meet certain criteria such as relatively simple construction of the generator and the direct coupling between the generator and the wind turbines. The simple construction and the lack of any gearbox would allow for such a system to be constructed relatively cheaply, which is a key aspect in further system development.

17 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
Dariusz KarkosińskiDariusz Karkosiński
Dariusz Karkosiński
WRWojciech Aleksander Rosiński
Wojciech Aleksander Rosiński
PDPiotr Deinrych
Piotr Deinrych
SPSzymon Potrykus
Szymon Potrykus
This paper presents an innovative approach to the design of a forthcoming, fully electric-powered cargo vessel. This work begins by defining problems that need to be solved when designing vessels of this kind. Using available literature and market research, a solution for the design of a power management system and a battery management system for a cargo vessel of up to 1504 TEU capacity was developed. The proposed solution contains an innovative approach with three parallel energy sources. The solution takes into consideration the possible necessity for zero-emission work with the optional function of operation as an autonomous vessel. Energy storage system based on lithium-ion battery banks with a possibility of expanding the capacity is also described in this work as it is the core part of the proposed solution. It is estimated that the operation range for zero-emission work mode of up to 136 nautical miles can be achieved through the application of all fore-mentioned parts.

29 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
MPMichał Pacholczyk
Michał Pacholczyk
Dariusz KarkosińskiDariusz Karkosiński
Dariusz Karkosiński
A small Counter-Rotating Wind Turbine (CRWT) has been proposed and its performance has been investigated numerically. Results of a parametric study have been presented in this paper. As parameters, the axial distance between rotors and a tip speed ratio of each rotor have been selected. Performance parameters have been compared with reference to a Single Rotor Wind Turbine (SRWT). Simulations were carried out with Computational Fluids Dynamics (CFD) solver and a Large Eddy Scale approach to model turbulences. An Actuator Line Model has been chosen to represent rotors in the computational domain. Summing up the results of simulation tests, it can be stated that when constructing a CRWT turbine, rotors should be placed at a distance of at least 0.5 D (where D is rotor outer diameter) or more. One can then expect a noticeable power increase compared to a single rotor turbine. Placing the second rotor closer than 0.5 D guarantees a significant increase in power, but in such configurations, dynamic interactions between the rotors are visible, resulting in fluctuations in torque and power. Dynamic interactions between rotor blades above 0.5 D are invisible.

2 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
MMMichal Michna
Michal Michna
FKFilip Kutt
Filip Kutt
ŁSŁukasz Sienkiewicz
Łukasz Sienkiewicz
RRRoland Ryndzionek
Roland Ryndzionek
GKGrzegorz Kostro
Grzegorz Kostro
BGBartłomiej Grochowski
Bartłomiej Grochowski
In this paper, the static and dynamic simulations, and mechanical-level Hardware-In-the-Loop (MHIL) laboratory testing methodology of prototype drive systems with energy-saving permanent-magnet electric motors, intended for use in modern construction cranes is proposed and described. This research was aimed at designing and constructing a new type of tower crane by Krupiński Cranes Company. The described research stage was necessary for validation of the selection of the drive system elements and confirmation of its compliance with applicable standards. The mechanical construction of the crane was not completed and unavailable at the time of testing. A verification of drive system parameters had to be performed in MHIL laboratory testing, in which it would be possible to simulate torque acting on the motor shaft. It was shown that the HIL simulation for a crane may be accurate and an effective approach in the development phase. The experimental tests of selected operating cycles of prototype crane drives were carried out. Experimental research was performed in the LINTE^2 laboratory of the Gdańsk University of Technology (Poland), where the MHIL simulator was developed. The most important component of the system was the dynamometer and its control system. Specialized software to control the dynamometer and to emulate the load subjected to the crane was developed. A series of tests related to electric motor environmental parameters was carried out.

24 September 2024 in Archives of Electrical Engineering
Verified
Journal Article
Open access
PDF file
AJAleksander Jakubowski
Aleksander Jakubowski
LLLech Lipinski
Lech Lipinski
DKDawid Kwiatkowski
Dawid Kwiatkowski
Dariusz KarkosińskiDariusz Karkosiński
Dariusz Karkosiński
NKNatalia Karkosińska-Brzozowska
Natalia Karkosińska-Brzozowska
In European countries, electrified routes amount for 40% to 65% of the total railway networks length. Some of those routes are only partially electrified, and construction of a catenary network might not be viable on all routes. Consequently, operators run diesel trains under catenary or require both an electric and diesel vehicle, increasing costs of operation. Dual-mode vehicles exist, but they are mostly equipped with diesel generators, adding to the pollution and resulting in reduced movement dynamics. In this article, the authors present a hydrogen-hybrid electric multiple unit (HEMU), as an environmentally friendly vehicle for partially electrified railway lines. Insight into technologies utilized by both hybrid and hydrogen rail vehicles based on the literature review allowed for the formulation of requirements for such a vehicle. Furthermore, an approach to a modelling hybrid vehicle is described, including an energy management algorithm. A series of simulations were conducted, showing an operation of an HEMU on a partially electrified suburban/regional route. The presented simulation results show potential for the future introduction of hydrogen hybrid electric multiple units as a viable solution for partially electrified local and regional routes.