Vladimir Arturo Reyes Herrera

Dr. Vladimir Arturo Reyes Herrera

Instituto de Energías Renovables
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Energy and Buildings
Verified
Journal Article
Closed access
Vladimir Arturo Reyes HerreraVladimir Arturo Reyes Herrera
Vladimir Arturo Reyes Herrera
SMSara L. Moya
Sara L. Moya
JMJ.M. Morales
J.M. Morales
Fernando Z Sierra-espinosaFernando Z Sierra-espinosa
Fernando Z Sierra-espinosa

1 November 2015 in Energy and Buildings
Verified
Journal Article
Closed access
Vladimir Arturo Reyes HerreraVladimir Arturo Reyes Herrera
Vladimir Arturo Reyes Herrera
Fernando Z Sierra-espinosaFernando Z Sierra-espinosa
Fernando Z Sierra-espinosa
SMSara L. Moya
Sara L. Moya
FCF. Carrillo
F. Carrillo

3 August 2020 in Processes
Verified
Journal Article
Open access
PDF file
FRFrancisco Josué Hernandez Rangel
Francisco Josué Hernandez Rangel
ZSZenaida Saavedra
Zenaida Saavedra
JMJosefa Morales
Josefa Morales
Horacio Bautista-SantosHoracio Bautista-Santos
Horacio Bautista-Santos
Vladimir Arturo Reyes HerreraVladimir Arturo Reyes Herrera
Vladimir Arturo Reyes Herrera
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
The rheological characterization of fluids using a rheometer is an essential task in food processing, materials, healthcare or even industrial engineering; in some cases, the high cost of a rheometer and the issues related to the possibility of developing both electrorheological and magnetorheological tests in the same instrument have to be overcome. With that in mind, this study designed and constructed a low-cost rotational rheometer with the capacity to adapt to electro- and magneto-rheological tests. The design team used the method of continuous improvement through Quality Function Deployment (QFD) and risk analysis tools such as Failure Mode and Effect Analysis (FMEA) and Finite Element Analysis (FEA). These analyses were prepared in order to meet the customer’s needs and engineering requirements. In addition to the above, a manufacturing control based on process sheets was used, leading to the construction of a functional rheometer with a cost of USD $1500.

5 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJosefa Morales
Josefa Morales
MRMiguel A. Rivera-Cruz
Miguel A. Rivera-Cruz
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
Horacio Bautista-SantosHoracio Bautista-Santos
Horacio Bautista-Santos
ICIlse Cervantes-Camacho
Ilse Cervantes-Camacho
Vladimir Arturo Reyes HerreraVladimir Arturo Reyes Herrera
Vladimir Arturo Reyes Herrera
The use of electric vehicles and their various configurations is seen as a major alternative in efforts towards reducing pollutant emissions from motor vehicles that continue to use fossil fuels. Electric transport technology presents more efficient means of energy conversion in vehicles: electric (EV), hybrid (VH), and hybrid electric (HEV) vehicles. For example, the energy storage system in the latter can be made up of ultracapacitors (UCs), batteries (Bs), and fuel cells. This work focuses on HEVs powered by batteries and ultracapacitors. In particular, the multiple converter configuration (C-CM) for the HEV powertrain system is analyzed using electric models of the vehicle powertrain components. To analyze the multiple converter configuration, parameters of a vehicle taken from the literature and the electrical model of the configuration were developed. With the above, the proposed configuration was evaluated before driving cycles (CITY II and ECE) and the configuration performance was compared with respect to other configurations. In the C-CM model, limitations in the choice of the number of Bs and UCs were observed in the powertrain depending on the maximum power of both energy sources and vehicle load demand. The results show that more energy is extracted from the batteries in the ECE cycle than in the CITY taking into account that the batteries are used as the main power source. C-CM results compared to other configurations show that energy extracted from batteries in the CITY is the same across all configurations. While energy consumption is lower in the ECE, C-CM results were not very significant compared to other configurations. However, the C-MC has the advantage of having better power flow control due to having two converters, thus improving HEV safety.

10 October 2026 in Fluids
Verified
Journal Article
Open access
PDF file
Ángel Sánchez-CruzÁngel Sánchez-Cruz
Ángel Sánchez-Cruz
EREduardo Ramos
Eduardo Ramos
Vladimir Arturo Reyes HerreraVladimir Arturo Reyes Herrera
Vladimir Arturo Reyes Herrera
Edmundo Amaya-GallardoEdmundo Amaya-Gallardo
Edmundo Amaya-Gallardo
SPSaul Piedra
Saul Piedra
The wind pressure coefficient CP is a key aerodynamic parameter for describing wind-induced pressure fields on building envelopes and is widely used as an input in air flow network (AFN) models. Most CFD validation studies rely on wall-averaged CP or a limited number of center-line sensors, implicitly assuming these represent the entire surface, which can mask significant local discrepancies. In this work, Reynolds-averaged Navier–Stokes (RANS) simulations are validated against pointwise pressure-tap data from the Tokyo Polytechnic University (TPU) database for an isolated low-rise hexahedral building. Wind incidence angles of 0°, 15°, 30°, and 45° are analyzed using five turbulence closures: standard, realizable, and RNG k-ϵ, and standard and SST k-ω. All simulations are performed in an icositetragon-shaped computational domain using OpenFOAM, allowing wind-direction changes without remeshing. While wall-averaged CP shows good agreement with experimental data for all models, local (tap-by-tap) comparisons reveal errors as high as 30–45% on leeward walls, exposing discrepancies that global metrics conceal. No single turbulence model performs best across all walls and incidence angles: RNG k-ϵ and SST k-ω alternate as the top performer depending on wall orientation and wind direction, a pattern quantified here through a wall-by-angle model-selection map based on the normalized mean square error. The results and the underlying local CP dataset provides practical guidance for selecting a turbulence model according to the dominant wind direction and facade orientation of a given natural-ventilation case, as well as a reference dataset for future wind-driven ventilation studies.