Francisco Josué Hernandez Rangel

Mr. Francisco Josué Hernandez Rangel

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JMJulio A. Mendoza-Escamilla
Julio A. Mendoza-Escamilla
FRFrancisco Josué Hernandez Rangel
Francisco Josué Hernandez Rangel
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
ZSZenaida Saavedra
Zenaida Saavedra
JMJosefa Morales
Josefa Morales
FMFrancisco J. Martinez-Lopez
Francisco J. Martinez-Lopez
Worldwide, the shortage of fresh water has increased exponentially due to population growth and contamination of available water, especially in water tables that provide water for general consumption. One of the main pollutants of water is arsenic (As), present in the environment and in most mining/metallurgical processes, which is a major health risk, especially as a carcinogen. In the region of Matehuala, San Luis Potosi (SLP), Mexico, a highly productive mining area, arsenic concentrations of 138.1 mg/kg have been found in soils—6.2 times higher than what is allowed in domestic soils, while in water it is reported up to 158 mg/L, exceeding permissible limits for human consumption. In addition to As pollution, the region suffers from water shortage both in the city and in rural communities. Therefore, it is necessary to explore new technologies to provide the population with fresh water. This paper presents a feasibility study on the use of an atmospheric water generator (AWG) to capture fresh water in the region of Matehuala, SLP. The region was found to have the necessary environmental conditions to use AWGs, with an annual average relative humidity (RH) of approximately 60%. Using a mathematical model of a dehumidifier, water harvesting can be evaluated under the region’s prevailing climatic conditions. The month with lowest harvest was found to be January, with 0.89 to 3.6 L/day, while the month with largest harvest was August at 3.9 to 18 L/day and water production costs of 0.0093 and $ 0.038 USD/L, respectively. The study concludes that the use of AWGs would help alleviate water shortages, thus benefiting marginalized people or communities, preserving ecosystems and the environment.

1 March 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
FRFrancisco Josué Hernandez Rangel
Francisco Josué Hernandez Rangel
MZMa. Lourdes Zuñiga
Ma. Lourdes Zuñiga
JRJose Maria Rodríguez
Jose Maria Rodríguez
Rafael Alfonso Figueroa DíazRafael Alfonso Figueroa Díaz
Rafael Alfonso Figueroa Díaz
ZPZaira Pineda
Zaira Pineda
This work presents the design of a new breast prosthesis using the biomimetic technique for cases of complete mastectomy to address the problem of the increasing number of women diagnosed with breast cancer in Mexico who are candidates for a mastectomy. The designed prosthesis considers the morphology of a real breast regarding its internal structure to obtain authentic mobility and feel. In order to accomplish this, a model was obtained in 3D CAD using a coordinate measuring machine (CMM) that can be scalable without losing its qualities, and which can be used in any type of patient; afterwards, a finite element model was developed and a static analysis performed with suggested load cases to evaluate the sensitivity and naturalness of the prosthesis; and finally, a modal analysis was conducted. The results obtained in displacements and in distribution of stress for the load cases assessed are consistent with those of a real breast: there were smooth contours and there was natural mobility in the prosthesis designed by means of the biomimetic technique.

3 August 2020 in Processes
Verified
Journal Article
Open access
PDF file
FRFrancisco Josué Hernandez Rangel
Francisco Josué Hernandez Rangel
ZSZenaida Saavedra
Zenaida Saavedra
JMJosefa Morales
Josefa Morales
Horacio Bautista-SantosHoracio Bautista-Santos
Horacio Bautista-Santos
Vladimir Arturo Reyes HerreraVladimir Arturo Reyes Herrera
Vladimir Arturo Reyes Herrera
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
The rheological characterization of fluids using a rheometer is an essential task in food processing, materials, healthcare or even industrial engineering; in some cases, the high cost of a rheometer and the issues related to the possibility of developing both electrorheological and magnetorheological tests in the same instrument have to be overcome. With that in mind, this study designed and constructed a low-cost rotational rheometer with the capacity to adapt to electro- and magneto-rheological tests. The design team used the method of continuous improvement through Quality Function Deployment (QFD) and risk analysis tools such as Failure Mode and Effect Analysis (FMEA) and Finite Element Analysis (FEA). These analyses were prepared in order to meet the customer’s needs and engineering requirements. In addition to the above, a manufacturing control based on process sheets was used, leading to the construction of a functional rheometer with a cost of USD $1500.

1 September 2026 in Dairy
Verified
Journal Article
Open access
PDF file
MTMaría Terrones-Gurrola
María Terrones-Gurrola
IMIsaac Compean Martinez
Isaac Compean Martinez
FRFrancisco Josué Hernandez Rangel
Francisco Josué Hernandez Rangel
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
Artisanal fresh goat cheese produced under traditional small-scale conditions may harbor antimicrobial-resistant pathogens. This study assessed the occurrence and geographic distribution of Staphylococcus aureus, characterized antimicrobial resistance, and explored the antibacterial activity of titanium dioxide (TiO2) against multidrug-resistant (MDR) isolates in the Altiplano Potosino region of Mexico. A total of 150 samples from 15 rural communities in seven municipalities were analyzed. Of 38 presumptive isolates, 24 were confirmed as S. aureus (16.0% of samples), occurring only in Charcas and Vanegas. Based on locality-level susceptibility profiles, 9 of 24 confirmed isolates (37.5%) were assigned an MDR phenotype involving macrolides, lincosamides, and aminoglycosides, with clindamycin resistance observed across all five positive localities. In exploratory assays, UV-C-activated TiO2 produced the largest inhibition zones and lowest viable counts. Viable counts were significantly lower under UV-C than under natural sunlight (p = 0.016), but not significantly different from darkness after Bonferroni adjustment (p = 0.073). These findings establish a regional baseline for S. aureus occurrence and antimicrobial resistance and provide preliminary evidence of measurable antibacterial activity of UV-C-activated TiO2 against MDR isolates.

4 August 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
FRFrancisco Josué Hernandez Rangel
Francisco Josué Hernandez Rangel
MFMARTHA ANGÉLICA CANO FIGUEROA
MARTHA ANGÉLICA CANO FIGUEROA
JCJorge Corona Castuera
Jorge Corona Castuera
JRJosé Eduardo Monsiváis Rocha
José Eduardo Monsiváis Rocha
MTMaría Terrones-Gurrola
María Terrones-Gurrola
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
External breast prostheses remain the primary noninvasive alternative after mastectomy; however, most commercial designs do not adequately reproduce natural breast biomechanics, heat dissipation, and ventilation behavior during daily activities. This study presents an integrated numerical framework for the ergonomic evaluation of a biomimetic external breast prosthesis under realistic use conditions. A multilayer prosthesis–torso assembly was generated through 3D digitization and modeled using nonlinear hyperelastic finite element formulations. The proposed design incorporated biomimetic lobular internal architecture and microsphere-based posterior ventilation configurations to improve load distribution and heat dissipation. Dynamic behavior was evaluated through modal, harmonic, and spectral analyses, while thermal and airflow simulations were used to assess interface temperature reduction and ventilation efficiency. The results showed physiologically acceptable dynamic displacements, without critical stress concentrations and natural frequencies outside dominant gait excitation ranges. Additionally, biomimetic ventilation configurations reduced contact temperatures by up to 6.58 °C compared with conventional commercial geometries. Overall, the proposed architecture demonstrated mechanical stability, improved thermal performance, ergonomic compatibility, and potential for personalized prosthesis design.

22 September 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
MTMaría Terrones-Gurrola
María Terrones-Gurrola
Héctor Arturo Álvarez MacíasHéctor Arturo Álvarez Macías
Héctor Arturo Álvarez Macías
IMIsaac Compean Martinez
Isaac Compean Martinez
FRFrancisco Josué Hernandez Rangel
Francisco Josué Hernandez Rangel
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
Access to microbiologically safe water in preschool educational settings constitutes a pressing public health challenge, particularly in rural areas with deficient infrastructure. Repeated exposure to enteropathogens present in contaminated water has been associated with acute gastrointestinal infections, environmental enteropathy, and disruptions in the intestinal microbiota of young children. Motivated by this concern, the present study evaluates the microbiological quality of water in 32 public preschool facilities in the municipality of Matehuala, San Luis Potosí—18 urban and 14 rural—by analyzing the presence of aerobic mesophilic bacteria (AMB), total coliforms (TC), fecal coliforms (FC), and helminth eggs. The assessment was conducted in accordance with Mexican standards NOM-092-SSA1-1994 and NOM-230-SSA1-2002 and supplemented with the World Health Organization’s guidelines for drinking-water quality. The findings revealed a marked territorial disparity: 100% of rural schools that relied on rooftop water tanks exceeded permissible limits for TC, and 35.7% tested positive for FC. In contrast, all urban schools—supplied through piped water systems—complied with current regulations. Statistical analysis (Mann–Whitney U test, p < 0.05) confirmed significant differences in microbiological contamination based on geographic location and type of water supply. In all FC-positive cases, a lack of sewage infrastructure and inadequate sanitation practices in storage containers were documented. These results demonstrate that formal access to water does not ensure its microbiological safety, particularly in settings with poor structural conditions. The study underscores the urgent need to implement point-of-use water treatment technologies, establish regular microbiological monitoring protocols, and provide training for educational staff in water hygiene practices.