Nerija Zurauskiene

Prof. Nerija Zurauskiene

Center for Physical Sciences and Technology, Department of Functional Materials and Electronics, Sauletekio ave. 3, 10257 Vilnius, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Ahmed TahaAhmed Taha
Ahmed Taha
Federico CasanovaFederico Casanova
Federico Casanova
Martynas TalaikisMartynas Talaikis
Martynas Talaikis
Voitech StankevicVoitech Stankevic
Voitech Stankevic
Nerija ZurauskieneNerija Zurauskiene
Nerija Zurauskiene
Arunas StirkeArunas Stirke
Arunas Stirke
Pulsed electric field (PEF) as a green processing technology is drawing greater attention due to its eco-friendliness and potential to promote sustainable development goals. In this study, the effects of different electric field strengths (EFS, 0–30 kV/cm) on the structure and physicochemical features of casein micelles (CSMs) were investigated. It was found that the particle sizes of CSMs increased at low EFS (10 kV/cm) but decreased at high EFS (30 kV/cm). The absolute ζ-potential at 30 kV/cm increased from −26.6 (native CSMs) to −29.5 mV. Moreover, it was noticed that PEF treatment leads to changes in the surface hydrophobicity; it slightly increased at low EFS (10 kV/cm) but decreased at EFS > 10 kV/cm. PEF enhanced the protein solubility from 84.9 (native CSMs) to 87.1% (at 10 kV/cm). PEF at low EFS (10 kV/cm) intensified the emission fluorescence spectrum of CSMs, while higher EFS reduced the fluorescence intensity compared to native CSMs. Moreover, the analysis of the Amide Ι region showed that PEF-treated CSMs reduced the α-helix and increased the β-sheet content. Raman spectra confirmed that PEF treatment > 10 kV/cm buried tyrosine (Tyr) residues in a hydrophobic environment. It was also found that PEF treatment mainly induced changes in the disulfide linkages. In conclusion, PEF technology can be employed as an eco-friendly technology to change the structure and physiochemical properties of CSMs; this could improve their techno-functional properties.

17 November 2009 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
OLOliver Liebfried
Oliver Liebfried
MLMarkus Loffler
Markus Loffler
MSMarkus Schneider
Markus Schneider
SBSaulius Balevicius
Saulius Balevicius
Voitech StankevicVoitech Stankevic
Voitech Stankevic
VPValentina Plausinaitiene
Valentina Plausinaitiene
We present local measurements of absolute values of pulsed magnetic fields in a typical electromagnetic launching system-a small coilgun. For this purpose, we designed magnetic field sensors based on thin polycrystalline La0.83Sr0.17MnO3 films exhibiting a colossal magnetoresistance (CMR) effect. We measured the magnetic field distribution inside the bore of a coilgun consisting of a multilayer coil and inserted a copper projectile in the shape of a hollow cylinder using an array of CMR-based sensors. In order to identify places with highly inhomogeneous magnetic field changes in direction and value, we simulated a pulsed magnetic field inside the coilgun. The measurements of magnetic induction compared well with simulations. CMR-based sensors are able to measure highly inhomogeneous magnetic fields in very small areas independently of the magnetic field direction with respect to the orientation of the sensor.

25 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Nerija ZurauskieneNerija Zurauskiene
Nerija Zurauskiene
Voitech StankevicVoitech Stankevic
Voitech Stankevic
SKSkirmantas Kersulis
Skirmantas Kersulis
MVMilita Vagner
Milita Vagner
VPValentina Plausinaitiene
Valentina Plausinaitiene
AWAndrzej Wisniewski
Andrzej Wisniewski
The results of colossal magnetoresistance (CMR) properties of La1-xSrxMnyO3 (LSMO) films grown by the pulsed injection MOCVD technique onto an Al2O3 substrate are presented. The grown films with different Sr (0.05 ≤ x ≤ 0.3) and Mn excess (y > 1) concentrations were nanostructured with vertically aligned column-shaped crystallites spread perpendicular to the film plane. It was found that microstructure, resistivity, and magnetoresistive properties of the films strongly depend on the strontium and manganese concentration. All films (including low Sr content) exhibit a metal–insulator transition typical for manganites at a certain temperature, Tm. The Tm vs. Sr content dependence for films with a constant Mn amount has maxima that shift to lower Sr values with the increase in Mn excess in the films. Moreover, the higher the Mn excess concentration in the films, the higher the Tm value obtained. The highest Tm values (270 K) were observed for nanostructured LSMO films with x = 0.17–0.18 and y = 1.15, while the highest low-field magnetoresistance (0.8% at 50 mT) at room temperature (290 K) was achieved for x = 0.3 and y = 1.15. The obtained low-field MR values were relatively high in comparison to those published in the literature results for lanthanum manganite films prepared without additional insulating oxide phases. It can be caused by high Curie temperature (383 K), high saturation magnetization at room temperature (870 emu/cm3), and relatively thin grain boundaries. The obtained results allow to fabricate CMR sensors for low magnetic field measurement at room temperature.

18 June 2018 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
Nerija ZurauskieneNerija Zurauskiene
Nerija Zurauskiene
SBS. Balevicius
S. Balevicius
VSV. Stankevic
V. Stankevic
SKS. Kersulis
S. Kersulis
JKJ. Klimantavicius
J. Klimantavicius
RNR. Navickas
R. Navickas

5 March 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
Voitech StankevicVoitech Stankevic
Voitech Stankevic
PSPovilas Simonis
Povilas Simonis
Nerija ZurauskieneNerija Zurauskiene
Nerija Zurauskiene
Arunas StirkeArunas Stirke
Arunas Stirke
ADAldas Dervinis
Aldas Dervinis
SBSaulius Balevicius
Saulius Balevicius
The design and development of a compact square-wave pulse generator for the electroporation of biological cells is presented. This electroporator can generate square-wave pulses with durations from 3 μs up to 10 ms, voltage amplitudes up to 3500 V, and currents up to 250 A. The quantity of the accumulated energy is optimized by means of a variable capacitor bank. The pulse forming unit design uses a crowbar circuit, which gives better control of the pulse form and its duration, independent of the load impedance. In such cases, the square-wave pulse form ensures better control of electroporation efficiency by choosing parameters determined in advance. The device has an integrated graphic LCD screen and measurement modules for the visualization of the current pulse, allowing for express control of the electroporation quality and does not require an external oscilloscope for current pulse recording. This electroporator was tested on suspensions of Saccharomyces cerevisiae yeast cells, during which, it was demonstrated that the application of such square-wave pulses ensured better control of the electroporation efficiency and cell viability after treatment using the pulsed electric field (PEF).

22 December 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Arunas StirkeArunas Stirke
Arunas Stirke
AZA. Zimkus
A. Zimkus
SBS. Balevicius
S. Balevicius
VSV. Stankevic
V. Stankevic
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene
Nerija ZurauskieneNerija Zurauskiene
Nerija Zurauskiene
The electrical field-induced changes of the yeast Saccharomyces cerevisiae cells permeabilization to tetraphenylphosphonium (TPP+) ions were studied using square-shaped, nanosecond duration high power electrical pulses. It was obtained that pulses having durations ranging from 10 ns to 60 ns, and generating electric field strengths up to 190 kV/cm significantly (up to 65 times) increase the absorption rate of TPP+ ions without any detectible influence on the yeast cell viability. The modelling of the TPP+ absorption process using a second order rate equation demonstrates that depending on the duration of the pulses, yeast cell clusters of different sizes are homogeniously permeabilized. It was concluded, that nanosecond pulse-induced permeabilization can be applied to increase the operational speed of whole cell biosensors.