In this paper, a simplified robust control is proposed to improve the performance of three phase current controlled voltage source inverter (VSI) connected to the grid through an LCL filter. The presence of the LCL filter resonance complicates the dynamics of the control system and limits its overall performance, particularly when disturbances and parametric uncertainty are considered. To solve this problem, a robust active damping method based on the Linear Active Disturbance Rejection Control (LADRC) is proposed. The simplification is made possible by order reduction in the plant transfer function using Padé approximation. Simulation results show that the proposed LADRC based current controller achieves high power quality and good dynamic performance, in the presence of parameters uncertainties as well as external disturbances. An experimental prototype is built to verify the effectiveness and practicality of the proposed control strategy.
Transient stability is important in power systems. Disturbances like faults need to be segregated to restore transient stability. A comprehensive review of fault diagnosing methods in the power transmission system is presented in this paper. Typically, voltage and current samples are deployed for analysis. Three tasks/topics; fault detection, classification, and location are presented separately to convey a more logical and comprehensive understanding of the concepts. Feature extractions, transformations with dimensionality reduction methods are discussed. Fault classification and location techniques largely use artificial intelligence (AI) and signal processing methods. After the discussion of overall methods and concepts, advancements and future aspects are discussed. Generalized strengths and weaknesses of different AI and machine learning-based algorithms are assessed. A comparison of different fault detection, classification, and location methods is also presented considering features, inputs, complexity, system used and results. This paper may serve as a guideline for the researchers to understand different methods and techniques in this field.
The objective of the research is to enhance the control performance of voltage source converter (VSC) stations within multi-terminal high voltage direct current (M-HVdc) grids under dynamic conditions. This paper presents the application of particle swarm optimization (PSO) to tune the control parameters of VSC stations. VSCs are non-linear components of the M-HVdc grids. Conventional techniques use approximated linear models to tune the control parameters which do not produce optimal results. Thus, PSO is employed to optimally tune the control parameters of VSC stations. The algorithm of the proposed objective function applies simultaneous optimization of inner and outer control layers. Dynamic simulations of a four-terminal HVdc system are developed in PSCAD/EMTDC to extol the merits of the presented optimization technique. Results show the steady state and dynamic control performances, both for classically and PSO based tuned parameters, during load demand change from ac grids, wind power change, and eventual permanent VSC disconnection.
In this paper, a simplified and robust control strategy of an interleaved high gain DC/DC boost converter (IHGBC) is proposed in order to enhance DC bus voltage regulation in proton exchange membrane fuel cell (PEMFC) applications. The fluctuation of the energy source voltage and external load, and the change in system parameters lead to the instability of output voltage. Based on the creation of an average state space model of the DC/DC boost converter, the proposed controller is designed based on a linear active disturbance rejection control (LADRC), which has an external voltage loop and an internal current loop to meet the output voltage requirements under parameters uncertainties and disturbances. The effectiveness of the proposed approach strategy and its superiority were examined under different operating conditions and scenarios. Simulation and experiment results showed the efficiency and robustness of the suggested approach and the great effectiveness in the reference tracking and disturbance rejection.
This paper deals with the problem of LCL filter resonance in grid connected inverter control. The system equations are reformulated to allow the application of the active disturbance rejection control (ADRC). The resonance, assumed unknown, is treated as a disturbance, then estimated and mitigated. By using this new robust control, a high level of performance is achieved with a minimum complexity in the controller design, and without any adaptive algorithm. It is demonstrated that the true quality of the control system is obtained by the proposed solution. Furthermore, it is shown that this control is robust against parameter variations and disturbances.