XUAN THANH PHAM

Dr. XUAN THANH PHAM

Faculty of Electronic Engineering, Ha Noi University of Industry, Number 298, Cau Dien Street, Bac Tu Liem, Ha Noi, Viet Nam
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
VNVan-Nhan Nguyen
Van-Nhan Nguyen
XPXUAN THANH PHAM
XUAN THANH PHAM
JLJong-Wook Lee
Jong-Wook Lee
Herein, we present a cyclic Vernier time-to-digital converter (TDC) using a stage-gated ring oscillator (SGRO) and data-weighted averaging (DWA) dynamic element matching (DEM). Using the phase-preserving characteristic of SGRO, DEM is realized using simple enable switches. DWA is achieved by storing the SGRO’s previous state and using it as the beginning state of the next conversion. This approach achieves cyclic selection of signal propagation paths in SGRO, and the systematic mismatch is averaged out through multiple conversions. DWA achieves the first-order mismatch correction, further improving linearity. Circuit techniques are presented to achieve accurate measurement by removing errors occurring in multiphase time-domain processing. A TDC fabricated with a 28-nm CMOS process is realized in a compact area of 0.0056 mm 2 . Measurements show that the TDC achieves an 8.5-ps resolution and an 11-bit dynamic range (DR). Full range linearity measurement shows a maximum differential nonlinearity (DNL) of 0.3 LSB and integral nonlinearity (INL) of 2.3 LSB. The power consumption is only 0.198 mW at a 15-MS/s conversion rate, resulting in a favorable figure of merit (FoM) of 0.021 pJ/conversion step. The results show the effectiveness of the proposed TDC for improved linearity and resolution.

8 July 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
XPXUAN THANH PHAM
XUAN THANH PHAM
DDDuc Nha Duong
Duc Nha Duong
NNNgoc Tan Nguyen
Ngoc Tan Nguyen
NTNguyen Van Truong
Nguyen Van Truong
JLJong-Wook Lee
Jong-Wook Lee
Achieving a high input impedance ${Z} _{\mathrm{ in}}$ is important for the instrumentation amplifier (IA) performing neural and biopotential signal sensing. Previously, impedance boosting techniques have been used with a positive feedback loop (PFL) driven by the output or auxiliary (AUX) path driven by the input. We propose that the conventional approach to DC-servo loop (DSL), which blocks the electrode offset (EOS), does not fully enable the function of a PFL or AUX path. This results in either limited impedance boosting or reduction of a low-frequency ${Z} _{\mathrm{ in}}$ in the sub-Hz band. To solve this problem and achieve ${Z} _{\mathrm{ in }}$ boosting down to sub-Hz, we propose a new approach to DSL for a capacitively-coupled chopper instrumentation amplifier (CCIA). The proposed DSL is realized using a 30-nA opamp, and the AUX path is designed using a 450-nA duty-cycled buffer. The CCIA achieves a gain of 40 dB and is implemented using a $0.18~\mu \text{m}$ CMOS process with an area of 0.19 mm 2 . The measured results show that ${Z} _{\mathrm{ in}}$ is increased by 184 times up to 4.6 $\text{G}{\Omega }$ at 0.01 Hz. Compared to the CCIA using conventional DSL, ${Z} _{\mathrm{ in}}$ is improved by 7.8 times. An input-referred noise of $2.1~\mu \text{V}_{\mathrm{ rms}}$ is achieved at $2.14~\mu \text{W}$ .

9 June 2021 in IEEE Access
Verified
Journal Article
Open access
XPXUAN THANH PHAM
XUAN THANH PHAM
NNNgoc Tan Nguyen
Ngoc Tan Nguyen
VNVan-Nhan Nguyen
Van-Nhan Nguyen
JLJong-Wook Lee
Jong-Wook Lee
This paper presents two designs of a capacitively-coupled chopper instrumentation amplifier (CCIA) successfully implemented in 28 nm CMOS for biopotential sensing applications. The first design is a compact CCIA using offset-blocking for chopping ripple reduction, DC servo loop (DSL) for electrode offset ( $V_{\mathrm {EOS}}$ ) suppression, and a high pass filter (HPF) for handling common-mode (CM) artifacts. An inverter-based self-biased input stage is used for noise and power efficiency. The two gain stages of the CCIA achieve a low-frequency open-loop gain >80 dB. Realized in an area of 0.05 mm 2 , the CCIA handles $V_{\mathrm {EOS}}$ up to 50 mV and tolerates CM artifacts up to $1.5~V_{\mathrm {pp}}$ . The CCIA achieves a mid-band gain of 39.5 dB with a 1 kHz bandwidth by consuming $1~\mu \text{W}$ . The integrated input-referred noise (IRN) over 200 Hz bandwidth is $2.15~\mu V_{\mathrm {rms}}$ . The second design presents a dual-channel CCIA (DCCIA) using an orthogonal frequency chopping for multi-sensor array applications. An inverter-based input stage is used for noise efficiency. The measured results show that the DCCIA achieves a low-frequency gain of 39.5 dB with a 3-dB bandwidth up to 1 kHz by consuming $0.71~\mu \text{W}$ per channel. The measured noise density is 136 nV/ $\surd $ Hz with an integrated noise of $2.67~\mu V_{\mathrm {rms}}$ over 200 Hz bandwidth. The DCCIA suppresses $V_{\mathrm {EOS}}$ up to 50 mV using the DSL. Realized in a compact area of 0.04 mm 2 per channel, an excellent gain matching error of 0.29% is achieved with the crosstalk higher than 58 dB between the channels. This work is a measured report on the instrumentation amplifier using, to the best of the authors’ knowledge, one of the smallest CMOS process nodes.

17 December 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
XPXUAN THANH PHAM
XUAN THANH PHAM
VNVan-Nhan Nguyen
Van-Nhan Nguyen
JKJie-Seok Kim
Jie-Seok Kim
JLJong-Wook Lee
Jong-Wook Lee
To realize an ultralow-power, low-noise amplifier for bio-potential recording, we investigate three design techniques. The first technique uses a noise-efficient squeezed inverter (SQI) stage biased at the supply of the 2VDSAT saturation limit. The challenge of interfacing the SQI stage with such a low supply is addressed by proposing a new capacitively-coupled chopper instrumentation amplifier (CCIA) with a low-noise DC servo loop (L-DSL) and an embedded ripple reduction loop (E-RRL). The second technique is reducing the high noise contribution of the conventional DSL. The proposed L-DSL reduces the inputreferred noise (IRN) by removing the charge dividing effect. The proposed E-RRL inserted inside the gain stage cancels the offset and achieves a ripple suppression without loading the output. The CCIA is implemented using a 0.18 μm CMOS process. The measured results show that the L-DSL successfully creates a sub-Hz high-pass corner needed to block the electrode offset. The ERRL achieves a ripple suppression of 39 dB. The CCIA achieves 32 nV/Hz noise density, which is slightly increased to 38 nV/Hz when the L-DSL is enabled. The integrated noise over 800 Hz bandwidth is 0.9 and 1.1 μVrms without and with the L-DSL, respectively. The mid-band gain of 39.6 dB is achieved by consuming 0.52 μW. These results correspond to a favorable noise efficiency factor (NEF) of 2.1 and a power efficiency factor (PEF) of 1.2.

6 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
XPXUAN THANH PHAM
XUAN THANH PHAM
TNTan Nguyen
Tan Nguyen
TNTruong Nguyen
Truong Nguyen
JLJong-Wook Lee
Jong-Wook Lee
To realize an ultra-low-power and low-noise instrumentation amplifier (IA) for neural and biopotential signal sensing, we investigate two design techniques. The first technique uses a noise-efficient DC servo loop (DSL), which has been shown to be a high noise contributor. The proposed approach offers several advantages: (i) both the electrode offset and the input offset are rejected, (ii) a large capacitor is not needed in the DSL, (iii) by removing the charge dividing effect, the input-referred noise (IRN) is reduced, (iv) the noise from the DSL is further reduced by the gain of the first stage and by the transconductance ratio, and (v) the proposed DSL allows interfacing with a squeezed-inverter (SQI) stage. The proposed technique reduces the noise from the DSL to 12.5% of the overall noise. The second technique is to optimize noise performance using an SQI stage. Because the SQI stage is biased at a saturation limit of 2VDSAT, the bias current can be increased to reduce noise while maintaining low power consumption. The challenge of handling the mismatch in the SQI stage is addressed using a shared common-mode feedback (CMFB) loop, which achieves a common-mode rejection ratio (CMRR) of 105 dB. Using the proposed technique, a capacitively-coupled chopper instrumentation amplifier (CCIA) was fabricated using a 0.18-µm CMOS process. The measured result of the CCIA shows a relatively low noise density of 88 nV/rtHz and an integrated noise of 1.5 µVrms. These results correspond to a favorable noise efficiency factor (NEF) of 5.9 and a power efficiency factor (PEF) of 11.4.

6 April 2022 in Electronics
Verified
Journal Article
Open access
PDF file
XPXUAN THANH PHAM
XUAN THANH PHAM
VKVu Trung Kien
Vu Trung Kien
TNTien Dzung Nguyen
Tien Dzung Nguyen
LPLoan Pham-Nguyen
Loan Pham-Nguyen
In this paper, a low-power and low-noise capacitive-coupled chopper instrumentation amplifier (CCIA) is proposed for biopotential sensing applications. A chopping technique is applied to mitigate the domination of flicker noise at low frequency. A new offset cancellation loop is also used to deal with the intrinsic offset, originating from process variation, to reduce ripple noise at the output of CCIA. Moreover, the optimization of the chip area was resolved by adding a T-network capacitor in the negative feedback loop. The CCIA is designed on 0.18 µm process CMOS technology with a total chip area of 0.09 mm2. The post-simulation results show that the proposed architecture can attenuate the output ripple up to 41 dB with a closed-loop gain of 40 dB and up to 800 Hz of bandwidth. The integrated input referred noise (IRN) of the CCIA is 1.8 µVrms over a bandwidth of 200 Hz. A noise efficiency factor (NEF) of 5.4 is obtained with a total power dissipation of 1.2 µW and a supply voltage of 1 V, corresponding to a power efficiency factor of 9.7 that is comparable with that of state-of-the-art studies.