Loan Pham-Nguyen

Dr. Loan Pham-Nguyen

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2022 in Electronics
Verified
Journal Article
Open access
PDF file
XPXUAN THANH PHAM
XUAN THANH PHAM
VKVu Trung Kien
Vu Trung Kien
TNTien Dzung Nguyen
Tien Dzung Nguyen
LPLoan Pham-Nguyen
Loan Pham-Nguyen
In this paper, a low-power and low-noise capacitive-coupled chopper instrumentation amplifier (CCIA) is proposed for biopotential sensing applications. A chopping technique is applied to mitigate the domination of flicker noise at low frequency. A new offset cancellation loop is also used to deal with the intrinsic offset, originating from process variation, to reduce ripple noise at the output of CCIA. Moreover, the optimization of the chip area was resolved by adding a T-network capacitor in the negative feedback loop. The CCIA is designed on 0.18 µm process CMOS technology with a total chip area of 0.09 mm2. The post-simulation results show that the proposed architecture can attenuate the output ripple up to 41 dB with a closed-loop gain of 40 dB and up to 800 Hz of bandwidth. The integrated input referred noise (IRN) of the CCIA is 1.8 µVrms over a bandwidth of 200 Hz. A noise efficiency factor (NEF) of 5.4 is obtained with a total power dissipation of 1.2 µW and a supply voltage of 1 V, corresponding to a power efficiency factor of 9.7 that is comparable with that of state-of-the-art studies.

17 September 2024 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
KNKim-Hoang Nguyen
Kim-Hoang Nguyen
QNQuyet Nguyen
Quyet Nguyen
QNQuynh-Trang Nguyen
Quynh-Trang Nguyen
TVThanh-Tung Vu
Thanh-Tung Vu
WAWoojin Ahn
Woojin Ahn
MJMinkyu Je
Minkyu Je
A fully integrated dynamic-voltage-scaling stimulator IC, consisting of a novel reconfigurable supply modulator (RSM) and 12 high-voltage-tolerant channel drivers, for cochlear implants, is presented, utilizing a 180-nm standard CMOS process. The RSM is designed to adaptively generate one of four supply voltage levels ranging from 2.6V to 11.3V, effectively stimulating the cochlea with varying electrode-tissue-interface impedance and stimulus currents while offering improved power efficiency. The channel driver design is miniaturized to support high-channel-count applications within a single IC. Additional excessive current protection is implemented to ensure charge balancing between biphasic stimulating pulses, complementing the electrode-shorting technique.

4 July 2018 in VNU Journal of Science: Computer Science and Communication Engineering
Verified
Journal Article
Open access
PDF file
NHNguyen Van Hao
Nguyen Van Hao
NMNguyen Duc Minh
Nguyen Duc Minh
LPLoan Pham-Nguyen
Loan Pham-Nguyen
In this paper, an adaptive and wide-range output DC-DC converter designed for lithium-ion (Li-Ion) battery charger circuit is proposed. The converter operates in continuous conduction mode (CCM) to provide an output voltage in response to battery voltage and a wide-range output current to ensure that circuit requirements are met. This circuit is designed on Cadence using 0.35-um BCD technology. Simulation results show that the circuit fully operates in CCM mode with a load current from 50 mA to 1000 mA and output voltage ripple factor is less than 1 %. Furthermore, the current supplied to the load circuit responses to three types of Li-Ion rechargeable currents. The output voltage of the converter varies from 2.8 to 4.5 V corresponding to the voltage range of the battery being charged from 2.5 to 4.2 V. The average power efficiency of the converter in large load current mode (1000 mA) reaches 94 %.

1 October 2025 in arXiv
Verified
Preprint
Open access
PDF file
TLTai Le
Tai Le
HLHau Luu
Hau Luu
LPLoan Pham-Nguyen
Loan Pham-Nguyen
HVHung Viet-Dao
Hung Viet-Dao
DMDuc Nguyen Minh
Duc Nguyen Minh
Hung CaoHung Cao
Hung Cao
Regular physiological monitoring of maternal and fetal parameters is indispensable for ensuring safe outcomes during pregnancy and parturition. Fetal electrocardiogram (fECG) assessment is crucial to detect fetal distress and developmental anomalies. Given challenges of prenatal care due to the lack of medical professionals and the limit of accessibility, especially in remote and resource-poor areas, we develop a fECG monitoring system using novel non-contact electrodes (NCE) to record the fetal/maternal ECG (f/mECG) signals through clothes, thereby improving the comfort during measurement. The system is designed to be incorporated inside a maternity belt with data acquisition, data transmission module as well as novel NCEs. Thorough characterizations were carried out to evaluate the novel NCE against traditional wet electrodes (i.e., Ag/AgCl electrodes), showing comparable performance. A successful {preliminary pilot feasibility study} conducted with pregnant women (n = 10) between 25 and 32 weeks of gestation demonstrates the system's performance, usability and safety.

24 July 2026 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
HTHan Trong Thanh
Han Trong Thanh
DTDat Tran Tien
Dat Tran Tien
LPLoan Pham-Nguyen
Loan Pham-Nguyen
1. In the digital era, rapid advancements in artificial intelligence (AI) have significantly accelerated the development of affective computing—a research paradigm originally introduced by Rosalind...

4 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TLTai Le
Tai Le
HLHau Luu
Hau Luu
LPLoan Pham-Nguyen
Loan Pham-Nguyen
VDViet-Hung Dao
Viet-Hung Dao
DMDuc Nguyen Minh
Duc Nguyen Minh
Hung CaoHung Cao
Hung Cao
Regular physiological monitoring of maternal and fetal parameters is indispensable for ensuring safe outcomes during pregnancy and parturition. Fetal electrocardiogram (fECG) assessment is crucial to detect fetal distress and developmental anomalies. Given challenges of prenatal care due to the lack of medical professionals and the limit of accessibility, especially in remote and resource-poor areas, we develop a fECG monitoring system using novel non-contact electrodes (NCE) to record the fetal/maternal ECG (f/mECG) signals through clothes, thereby improving the comfort during measurement. The system is designed to be incorporated inside a maternity belt with data acquisition, data transmission module as well as novel NCEs. Thorough characterizations were carried out to evaluate the novel NCE against traditional wet electrodes (i.e., Ag/AgCl electrodes), showing comparable performance. A successful preliminary pilot feasibility study conducted with pregnant women (n = 10) between 25 and 32 weeks of gestation demonstrates the system’s performance, usability and safety.