Thiemo Hein

Mr. Thiemo Hein

Technical University of Applied Sciences Würzburg-Schweinfurt, Würzburg, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Electric Power Systems Research
Verified
Journal Article
Closed access
THThiemo Hein
Thiemo Hein
AZAndreas Ziegler
Andreas Ziegler
DODavid Oeser
David Oeser
AAAnsgar Ackva
Ansgar Ackva

4 February 2021 in IEEE Access
Verified
Journal Article
Open access
AZAndreas Ziegler
Andreas Ziegler
DODavid Oeser
David Oeser
THThiemo Hein
Thiemo Hein
Daniel Montesinos-MiracleDaniel Montesinos-Miracle
Daniel Montesinos-Miracle
AAAnsgar Ackva
Ansgar Ackva
In this work, an experimental approach to reduce the variation from cell to cell during battery operation is evaluated to reach a better battery utilization. Numerous theoretical considerations of intelligent battery management systems without long-term experimental validation of their capabilities lead to a gap in the literature, which this work aims to address. For this purpose, the ageing behaviour of two batteries is investigated for almost 1.5 years. One battery is connected to an active balancing battery management system (BMS) and the other to a conventional passive balancing BMS. Important battery parameters, such as capacity and internal resistance, are recorded in each cycle. The battery behaviour is evaluated in detail by observing the voltage difference of the individual cells at the end of discharge and by calculating the amount of charge balanced by the BMS. Significant differences between the BMS systems used are elucidated, which illustrate the advantages of active balancing. In contrast to passive balancing, active balancing can reduce the ageing rate of the battery and achieve better utilization with a more than five times lower voltage spread at end of discharge, a up to 3.1% higher discharge capacity and a 7.7% longer service life.

17 March 2023 in Batteries
Verified
Journal Article
Open access
PDF file
THThiemo Hein
Thiemo Hein
DODavid Oeser
David Oeser
AZAndreas Ziegler
Andreas Ziegler
Daniel Montesinos-MiracleDaniel Montesinos-Miracle
Daniel Montesinos-Miracle
AAAnsgar Ackva
Ansgar Ackva
In this work, a battery consisting of eight commercial NMC/graphite cells connected in series was cycled to 60% of its initial capacity. During the test, special care was taken to ensure that the results were not influenced by either the module assembly or the module design. For this purpose, the cells were virtually connected in a laboratory environment with the help of the test device as if they were operated together in a battery. Extrinsic influences that affect cell aging were thus reduced to a minimum. Differential Voltage Analysis (DVA), Electrochemical Impedance Spectrum (EIS), and relaxation measurements were performed to analyze the aging behavior of each cell. The results show that despite a theoretically perfect module design, Cell-to-Cell Variations (CtCV) occurred during aging. The shifting Depth of Discharge (DoD) values among the cells further amplify CtCV. Lithium plating was also observed in the faster aging cells after cyclic aging, suggesting that this aging effect contributes significantly to the development of CtCV. After the aging test, the battery was equipped with an active balancing system that maximizes capacity utilization. More important, the balancing charges which are calculated iteratively within the used balancing algorithm show a strong correlation to the pure capacity losses and thus provide a new way to determine the capacity values of each cell individually without disassembling the battery.

1 October 2019
Verified
Conference Paper
Closed access
AZAndreas Ziegler
Andreas Ziegler
DODavid Oeser
David Oeser
THThiemo Hein
Thiemo Hein
AAAnsgar Ackva
Ansgar Ackva

11 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
AZAndreas Ziegler
Andreas Ziegler
DODavid Oeser
David Oeser
THThiemo Hein
Thiemo Hein
Daniel Montesinos-MiracleDaniel Montesinos-Miracle
Daniel Montesinos-Miracle
AAAnsgar Ackva
Ansgar Ackva
The aim of this work is to age commercial battery cells far beyond their expected lifetime. There is a gap in the literature regarding run to failure tests of lithium-ion batteries that this work intends to address. Therefore, twenty new Samsung ICR18650-26F cells were aged as a battery pack in a run to failure test. Aging took place with a constant load current and a constant charge current to accelerate capacity decrease. Important aging parameters such as capacity and internal resistance were measured at each cycle to monitor their development. The end of the test was initiated by the explosion of a single battery cell, after which the battery pack was disassembled and all parameters of the still intact single cells were measured. The distribution of all measured capacities and internal resistances is displayed graphically. This clearly shows the influence of the exploded cell on the cells in its immediate vicinity. Selected cells from this area of the battery were subjected to computed tomography (CT) to detect internal defects. The X-rays taken with computed tomography showed clear damage within the jelly roll, as well as the triggered safety mechanisms.

20 September 2024 in Journal of Energy Storage
Verified
Journal Article
Open access
DODavid Oeser
David Oeser
THThiemo Hein
Thiemo Hein
AZAndreas Ziegler
Andreas Ziegler
MSMichael Seefried
Michael Seefried
SGSebastian Gielinger
Sebastian Gielinger
AAAnsgar Ackva
Ansgar Ackva
In real applications, lithium-ion cells are usually used in individual interconnections, with the worst cell determining capacity, performance and service life. Due to different ageing rates of the assembled cells, cell-to-cell variation changes over lifetime. In literature, cell-to-cell variation is usually investigated near room temperature under one operating condition. Data regarding cell-to-cell variation above and below room temperature under different operating conditions are hard to find. To fill the gap in literature, this study considers cell-to-cell variation as a function of different charge/discharge currents at ambient temperatures between 0 °C and 40 °C on commercial NMC/graphite cells (Samsung SDI ICR18650-26J). The results demonstrate that cell-to-cell variation strongly depends on the selected operating conditions. In particular, operating conditions near the lithium plating boundary at the beginning of the ageing process have a particularly high risk of developing a pronounced variation. Fast charging or charging at lower temperatures should therefore be avoided. Operation at moderate temperatures and currents, on the other hand, only leads to a slight increase in cell-to-cell variation in the tests carried out. A 24-month storage during the testing period at 30% SOC and room temperature of the same cells shows even a slight reduction in cell-to-cell variation.