In this work, an experimental approach to reduce the variation from cell to cell during battery operation is evaluated to reach a better battery utilization. Numerous theoretical considerations of intelligent battery management systems without long-term experimental validation of their capabilities lead to a gap in the literature, which this work aims to address. For this purpose, the ageing behaviour of two batteries is investigated for almost 1.5 years. One battery is connected to an active balancing battery management system (BMS) and the other to a conventional passive balancing BMS. Important battery parameters, such as capacity and internal resistance, are recorded in each cycle. The battery behaviour is evaluated in detail by observing the voltage difference of the individual cells at the end of discharge and by calculating the amount of charge balanced by the BMS. Significant differences between the BMS systems used are elucidated, which illustrate the advantages of active balancing. In contrast to passive balancing, active balancing can reduce the ageing rate of the battery and achieve better utilization with a more than five times lower voltage spread at end of discharge, a up to 3.1% higher discharge capacity and a 7.7% longer service life.
Due to the fact, that there are basically no practical test comparisons between active and passive lithium-ion battery balancing systems, a long term test is carried out. Therefore two batteries with an active and a passive balancing system are cycled. After about 2600 cycles test is stopped to start with further investigations. Capacity decrease and the increase of internal resistance of the two used battery packs are presented. To investigate the influence of load cycles in combination with different battery management systems (BMS) a detailed single cell investigation is executed. Finally, active balancing increases the usable capacity by a maximum of 2% compared to passive balancing and reduces the cell to cell deviation of capacity and internal resistance. Furthermore it is shown that the additional stress due to frequent energy redistribution in active balancing systems has no negative ageing effects to the cells compared to passive balancing.
In this work, a battery consisting of eight commercial NMC/graphite cells connected in series was cycled to 60% of its initial capacity. During the test, special care was taken to ensure that the results were not influenced by either the module assembly or the module design. For this purpose, the cells were virtually connected in a laboratory environment with the help of the test device as if they were operated together in a battery. Extrinsic influences that affect cell aging were thus reduced to a minimum. Differential Voltage Analysis (DVA), Electrochemical Impedance Spectrum (EIS), and relaxation measurements were performed to analyze the aging behavior of each cell. The results show that despite a theoretically perfect module design, Cell-to-Cell Variations (CtCV) occurred during aging. The shifting Depth of Discharge (DoD) values among the cells further amplify CtCV. Lithium plating was also observed in the faster aging cells after cyclic aging, suggesting that this aging effect contributes significantly to the development of CtCV. After the aging test, the battery was equipped with an active balancing system that maximizes capacity utilization. More important, the balancing charges which are calculated iteratively within the used balancing algorithm show a strong correlation to the pure capacity losses and thus provide a new way to determine the capacity values of each cell individually without disassembling the battery.
1 May 2019 in IOP Conference Series: Earth and Environmental Science
Volume change of graphite leads to change in thickness of battery storage layers during discharging and charging. Pouch cell lithium ion batteries are used in the field of electric vehicles and solar home storage. This paper shows a measurement setup for the three-dimensional measurement of thickness change on a flat 6.7mm thick pouch cell using a white light interferometer. With a measuring field of 7.05mm diameter the resulting 3D thickness change record contains 226000 3D readings. The measuring points have a lateral distance of 13.1μm. The repeatability of the measurement is 312.8nm for the individual values and 64.1nm for the average value. In addition, this paper shows how the storage capacity of this pouch cell drops over 30 charge cycles.