KISHOR T. ZINGRE

Dr. KISHOR T. ZINGRE

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

17 July 2023 in Energy and Buildings
Verified
Journal Article
Open access
SSS. Shashwat
S. Shashwat
KISHOR T. ZINGREKISHOR T. ZINGRE
KISHOR T. ZINGRE
NTNiraj Thurairajah
Niraj Thurairajah
DKDevs Kiran Kumar
Devs Kiran Kumar
KPKrithika Panicker
Krithika Panicker
Man Pun WanMan Pun Wan
Man Pun Wan

16 January 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
NVNivetha Vadamalraj
Nivetha Vadamalraj
KISHOR T. ZINGREKISHOR T. ZINGRE
KISHOR T. ZINGRE
SBSubathra Bala
Subathra Bala
PAPandarasamy Arjunan
Pandarasamy Arjunan
SSSeshadhri Srinivasan
Seshadhri Srinivasan
Maintaining both indoor air quality (IAQ) and thermal comfort in buildings along with optimized energy consumption is a challenging problem. This investigation presents a novel design for hybrid ventilation system enabled by predictive control and soft-sensors to achieve both IAQ and thermal comfort by combining predictive control with demand controlled ventilation (DCV). First, we show that the problem of maintaining IAQ, thermal comfort and optimal energy is a multi-objective optimization problem with competing objectives, and a predictive control approach is required to smartly control the system. This leads to many implementation challenges which are addressed by designing a hybrid ventilation scheme supported by predictive control and soft-sensors. The main idea of the hybrid ventilation system is to achieve thermal comfort by varying the ON/OFF times of the air conditioners to maintain the temperature within user-defined bands using a predictive control and IAQ is maintained using Healthbox 3.0, a DCV device. Furthermore, this study also designs soft-sensors by combining the Internet of Things (IoT)-based sensors with deep-learning tools. The hardware realization of the control and IoT prototype is also discussed. The proposed novel hybrid ventilation system and the soft-sensors are demonstrated in a real research laboratory, i.e., Center for Research in Automatic Control Engineering (C-RACE) located at Kalasalingam University, India. Our results show the perceived benefits of hybrid ventilation, predictive control, and soft-sensors.

1 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
KISHOR T. ZINGREKISHOR T. ZINGRE
KISHOR T. ZINGRE
KSKiran Kumar D E V S
Kiran Kumar D E V S
Man Pun WanMan Pun Wan
Man Pun Wan
Existing regulations on the thermal efficiency of building envelope assemblies are based on the steady state thermal properties of substrate materials. Heat transfer mechanisms of passive heat curbing methods such as phase change materials and cool materials, which are dynamic in nature, are currently not being accounted for. The effectiveness of thermo-physical and solar radiation properties of building materials (i.e., solid homogeneous layers without air gap) in reducing the heat gain into a building in a hot climate could be well understood with the equivalent thermal resistance (Req) concept. A simple and easy-to-use mathematical derivation (i.e., to estimate the instantaneous heat flux across an envelope assembly) is proposed in this paper to understand the mechanism of equivalent R-value (i.e., reciprocal of thermal transmittance, U-value) due to solar radiation properties of passive substrate materials. The model is validated against field experiments carried out at two apartment units of a residential building. The Req due to high outer surface solar radiation properties (i.e., by applying a cool coating) is dynamic as it varies with the weather conditions. The effect of a substrate material’s solar radiation and thermo-physical properties on the overall roof thermal performance is investigated using the Req model for four cooling dominated climates around the globe, having different diurnal conditions and sky temperatures. Increasing the outer surface’s solar reflectance (from 10% to 80%) reduces net heat gain through the flat roof during both daytime and nighttime. In contrast, adding only thermal resistance (from 5 mm to 75 mm thick polyurethane) or volumetric heat capacity (by adding 5 mm thick phase change material) to the building envelope brings down heat gain during the day, but not in the night. Thermal insulation is found to be the second effective property, followed by thermal mass irrespective of different diurnal conditions and sky temperatures across the climates.

26 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
FFFiona Forster
Fiona Forster
KISHOR T. ZINGREKISHOR T. ZINGRE
KISHOR T. ZINGRE
SSShashwat Shashwat
Shashwat Shashwat
Residential heritage buildings (RHBs) are facing complex conservation challenges due to national policies aimed at achieving carbon emission reductions and associated retrofit recommendations. This long-term study (2007–ongoing) focuses on how such nationwide policies, particularly energy performance certificates (EPCs) and minimum energy efficiency standards (MEES), affect a cluster of 12 RHBs on the National Trust’s Wallington Estate in Northumberland, England. Data were collected using a combination of building measurements and survey observations, alongside assessment of tenant behaviours through an interview process. The research findings revealed a 53% average improvement in EPC ratings following a retrofit. However, the tenant interviews exposed some key limitations in current policy tools, including their failure to reflect actual energy use and behavioural patterns. For instance, despite improved EPC scores, some tenants reported high fuel costs and continued to experience heat loss and dampness in the RHBs. These novel findings of this longitudinal study challenge the suitability of current retrofit metrics and advocate for a people-centric and context-specific approach to energy efficiency in heritage buildings. They also highlight the drawback of proposed minimum EPC ‘C’ standards within the UK’s existing housing stock, particularly in relation to idiosyncratic RHBs.

25 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
KSKiran Kumar D E V S
Kiran Kumar D E V S
SSShashwat Shashwat
Shashwat Shashwat
KISHOR T. ZINGREKISHOR T. ZINGRE
KISHOR T. ZINGRE
SSSeshadhri Srinivasan
Seshadhri Srinivasan
Man Pun WanMan Pun Wan
Man Pun Wan
The measurement of globe temperature (GT) is essential for investigating pedestrian thermal comfort in street canyons. The globe thermometer is the most common instrument used to measure GT; however, its application in scale models has not been thoroughly investigated to date. Therefore, this study explicitly investigates globe thermometer measurements in scale models and analyzes the need for customization of the globe thermometer for more reliable measurements. Scaling down with respect to the size of the globe thermometer and the effect of solar orientation/envelope materials are investigated in this study. The initial experiments were carried out in an outdoor setting using a typical street canyon model (scale 1:100) with an east-west street orientation. The results of the experiment are presented to compare a low solar reflectance street canyon (albedo of 0.4) and a high solar reflectance canyon (albedo of 0.6) in terms of surface temperatures, heat flux, and globe temperature. It is observed that although the wall and road surface temperatures are lower for the high solar reflectance canyon compared to those for the low solar reflectance canyon, the GT (measured at pedestrian height) is higher in a high reflectance canyon during the daytime, which could be due to the combined effect of direct radiation and short-wave reflection. However, for the hours after sunset, a reverse effect is observed, i.e., the GT becomes lower (up to 0.8 °C) in the case of a high reflectance canyon compared to that for the low reflectance canyon. Furthermore, the study emphasizes the impact of solar reflectance of canyon surfaces on GT values, due to the view factors that the globe thermometer on those surfaces.